Home > Electrical & Electronics > Power Transmission & Transformer > Transformer > KUC711AE 3BHB004661R0001 Original Imported ABB Door Unit Power Supply (actual Goods)

KUC711AE 3BHB004661R0001 Original Imported ABB Door Unit Power Supply (actual Goods)

KUC711AE 3BHB004661R0001 Original Imported ABB Door Unit Power Supply (actual Goods) photo-1
KUC711AE 3BHB004661R0001 Original Imported ABB Door Unit Power Supply (actual Goods) photo-2
KUC711AE 3BHB004661R0001 Original Imported ABB Door Unit Power Supply (actual Goods) photo-3
KUC711AE 3BHB004661R0001 Original Imported ABB Door Unit Power Supply (actual Goods) photo-4
KUC711AE 3BHB004661R0001 Original Imported ABB Door Unit Power Supply (actual Goods) photo-5
US$ 100 - 200 MOQ: 100 Pounds
Key Specifications
Get Latest Price
Brand Name:
ABB
Model Number:
KUC711AE 3BHB004661R0001
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Brand Name ABB
Model Number KUC711AE 3BHB004661R0001

KUC711AE 3BHB004661R0001 Original imported ABB door unit power supply (actual goods)

KUC711AE 3BHB004661R0001 Original imported ABB door unit power supply (actual goods)


Our Email: 2235954483@qq.com

contact number:13313705507

contacts:HE


When the calculated negative phase-sequence voltage value U2s exceeds the set start

value of the stage U2>, the stage generates a start signal after a 50 ms' start time.

When the set operate time at definite-time characteristics or the calculated operate

time at IDMT characteristics elapses, the stage generates a trip signal. The stage is

reset in 70 ms after the calculated negative phase-sequence voltage value has fallen

below the set start value of the stage.

The negative phase-sequence voltage is calculated as follows:

U2s = U a U aU 12 + × +× 2

23 31

3 (1)

a =1∠ 120°

a

2 = 1∠ -120°

The negative phase-sequence value is scaled to the amplitude of the measured

voltage. On a network with a reverse phase order, the calculated negative phasesequence value has the same amplitude as the measured voltage signal.

Stage U2> can be set to be blocked when one of the measured phase-to-phase

voltages falls below 0.15 × Un. The selection is made in SGF4.

Stage U2> has a fixed drop-off/pick-up ratio of 0.96.

5.1.4.3. Undervoltage protection

The undervoltage protection can be based on either conventional voltage

measurement or the calculated positive phase-sequence voltage.

The low-set undervoltage stage U

The low-set stage can also be used for alarm purposes.

The high-set undervoltage stage U

* Conventional voltage measurement (U

* Calculated positive phase-sequence voltage (U1

Product Tags: KUC711AE , 3BHB004661R0001 , ABB KUC711AE

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location
Xiamen, Fujian, China

Recommended Categories

Explore top categories and find suppliers for your specific needs