Home > Electrical & Electronics > Optical Fiber, Cable & Wire > Electric Wire & Cable > GTACSR & GZTACSR Conductor Overhead Transmission Conductor Bare Conductor

GTACSR & GZTACSR Conductor Overhead Transmission Conductor Bare Conductor

GTACSR & GZTACSR Conductor Overhead Transmission Conductor Bare Conductor photo-1
GTACSR & GZTACSR Conductor Overhead Transmission Conductor Bare Conductor photo-2
US$ 1 - 1.1 MOQ: 5000 Meters
Key Specifications
Get Latest Price
Brand Name:
Qingzhou
Place of Origin:
China
Type:
High Voltage
Payment & Shipping
Payment Methods:
Port of Shipment:
Qingdao
Delivery Detail:
Delivery time depends on order quantity.
Brand Name Qingzhou
Place of Origin China
Type High Voltage
Application Overhead
Insulation Material Other, without
Jacket Other, without
Conductor Material Aluminum

Application

High Temperature Thermal Resistant Alloy Conductor : Aluminum-Zirconium wires (Type-AT1 or AT3), concentrically stranded over a steel core having a small gap between the Steel core & thermal-resistant aluminum alloy layer. These combination offers best Mechanical as well as Electrical Characteristics. 

Extra High Strength Galvanized Steel (EST); or aluminum-claded Extra High Strength Steel (AW). Additional corrosion protection is achieved as High Temperature Grease is applied in Between GAP of Conductor.

gztacsr.png

Construction

Aluminium-Zirconium wires (Type-AT3 or AT-1), concentrically stranded over a steel core maintaing gap between the Steel core and first Aluminium Layer.

Values based on following Specifications:

• Thermal-resistant aluminium alloy wires (Type-AT3 or AT1) for overhead line conductor as per IEC 62004

• Concentric lay stranded overhead electrical conductors IEC 61089, IEC 62420

• Zinc-coated steel wires for stranded conductors IEC 888, ASTM B957 & more

• Zinc–5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire EN 50540, ASTM B802, ASTM B803 or ASTM B958.

• Aluminium Clad Steel Wires, IEC 61232, ASTM B415, EN 50540 & More


Features:

• These can operate upto 210°C with specified strength loss,

• Can carry 100~150% more current as that of ACSR of the same size.

• For uprating lines, no modifications or reinforcement is required to the existing towers

• Limiting the sag increase with the increase of the temperature by the thermal expansion coefficient above knee-point related to the steel core


Product Tags: GTACSR Conductor , bare conductor , GZTACSR Conductor