Product Introduction
The JYJXC-3000 type has pole reinforced contact relay is used as a pole-changing relay in the switch circuit.
Features
1. The relay is designed according to the needs of the bistable circuit in the signal circuit. Permanent magnets are added to the magnetic circuit system of the relay, so that the relay has two stable states of positioning and reverse due to the different polarity of the current in the coil. These two stable states can continue to be maintained after the current in the coil disappears.
2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance.
3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay.
4. The contact system is composed of ordinary contacts and reinforced contacts. There are two sets of reverse common contacts, two sets of positioning and reverse conversion reinforced contacts with arc-extinguishing magnets.
The strengthened contact of the relay is specially designed for turning on the high current of the switch point machine.
5. The rated voltage of the relay is DC 80V.
Features
1. The relay is designed according to the needs of the bistable circuit in the signal circuit. Permanent magnets are added to the magnetic circuit system of the relay, so that the relay has two stable states of positioning and reverse due to the different polarity of the current in the coil. These two stable states can continue to be maintained after the current in the coil disappears.
2. The use of silver-silver oxidation requires contacts, which has the characteristics of strong anti-adhesion and low contact resistance.
3. The relay contact system is composed of common contacts and reinforced contacts. There are two sets of positioning and reverse conversion common contacts, and two sets of positioning and reverse conversion reinforced contacts with arc-extinguishing magnets. The strengthened contact of the relay is specially designed for turning on the high current of the switch point machine.
4. The rated voltage of the relay is DC 24V.
Applicable environment
a) Ambient temperature: -40℃~+60℃;
b) Relative humidity: not more than 90% (temperature +25℃);
c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m);
d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm;
e) Working position: horizontal;
f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
Dimensions
Relay: 165mm×49mm×163mm (length×width×height)
Socket: 157mm×48mm×22mm (length×width×height)
Installation method
The relay socket is installed on the combination frame (cabinet) with bolts, and the relay is inserted into the socket horizontally and clamped with a hanging spring.
Relay identification pin numbers 15, 54.
Applicable characteristics Mechanical characteristics
Number of contact groups: 2DF, 2DFJ;
Identification pin number: 15, 54;
Contact gap: ordinary contact is not less than 4.5mm; reinforced contact is not less than 7mm;
Pallet gap: ordinary contact point is not less than 0.35mm; strengthened contact point 0.1mm~0.3mm;
Ordinary contact pressure: the positioning contact is not less than 150mN; the reverse contact is not less than 150mN;
Strengthen the contact pressure: the positioning contact is not less than 400mN; the reverse contact is not less than 400mN;
Contact uniformity error: no more than 0.2mm between ordinary contacts and ordinary contacts and between ordinary contacts and reinforced contacts, and no greater than between reinforced contacts and reinforced contacts 0.1mm.
Positioning or reverse position retention force is not less than 2N;
Electrical characteristics (at +20℃)
Coil resistance: 220/220Q
Use the coil alone, use 1, 23, 4;
Rated value: 24V;
Magnetizing value: 64V/64V;
Rotation extreme value: forward 10V~16V, reverse 10V~16V;
Contact resistance: ordinary contact is not more than 0.05Q; strengthened contact is not more than 0.1Q.
maintenance
Daily maintenance and maintenance items are as follows:
a) Keep the relay and socket clean;
b) Observe whether the relay operation status is normal;
Send Inquiry to This Supplier
You May Also Like
-
JJJC1 AC Enhanced Contact RelayNegotiableMOQ: 99 Short Tons
-
JJJC5 AC Enhanced Contact RelayNegotiableMOQ: 99 Short Tons
-
JSBXC1-870 Programmable Time RelayNegotiableMOQ: 99 Short Tons
-
JSBXC-780 Programmable Time RelayNegotiableMOQ: 99 Short Tons
-
JSBXC1-850 Programmable Time RelayNegotiableMOQ: 99 Short Tons
-
JMS2-110 Pulse RelayNegotiableMOQ: 99 Short Tons
-
JZSJC2 AC Filament Conversion RelayNegotiableMOQ: 99 Short Tons
-
JMS2-110 Pulse RelayNegotiableMOQ: 99 Short Tons
-
JZSJC2 AC Filament Conversion RelayNegotiableMOQ: 99 Short Tons
-
JMS2-110 Pulse RelayNegotiableMOQ: 1 Bag