NSS ACSS CASS Accelerated Corrosion Salt Spray Test Chamber
NSS ACSS CASS Accelerated Corrosion Salt Spray Test Chamber
Equipment summary:
NSS ACSS CASS Accelerated Corrosion Salt Spray Test Chamber used to test the corrosive resistance of products whose the surface was treated with paint, electroplating, inorganic and organic film, anode handling, anti-rust oil,etc.
Technical parameters :
Model | ZT-60 | ZT-90 | ZT-120 |
Inside box size(cm) | 60x45x40 | 90x60x50 | 120x80x50 |
Outside box size(cm) | 107x60x118 | 141x88x128 | 190x110x140 |
Testing room temperature | Salt test (NSS ACSS)35℃±1℃/ Corrosion Test (CASS)50℃±1℃ | ||
Pressure barrel temperature | Salt test (NSS ACSS)47℃±1℃/ Corrosion Test (CASS)63℃±1℃ | ||
Brine temperature | 35℃±1℃ 50℃±1℃ | ||
Testing room Capacity | 108L | 270L | 480L |
Brine tank capacity | 15L | 25L | 40L |
Salt concentration | The concentration of sodium chloride 5% or the 5% concentration of sodium chloride add 0.26g per liter of copper chloride (CuCl2 2H2O) | ||
Air pressure | 1.00±0.01kgf/cm2 | ||
Spray volume | 1.0~2.0ml/80cm2/h (working at least 16 hours, and then take the average) | ||
Testing room relative humidity | 85% above | ||
PH | 6.5~7.2 3.0~3.2 | ||
Spray form | Programmable spray (Including continuous and intermittent spray) | ||
Power | AC220V1Φ10A | AC220V1Φ15A | AC220V1Φ20A |
Corresponding standard :
1.GB/T 2423.17-1993 salt spray test
2.GB/T 2423.18-2000 salt spray test
3.GB/T 10125-1997 salt spray test
4.ASTM.B117-97 salt spray test
5.JIS H8502 salt spray test
6.IEC68-2-11 salt spray test
7.IEC68-2-52 1996 salt spray test
8.GB.10587-89 salt spray test
9.CNS.4158 salt spray test
10.CNS.4159 CASS Accelerated acetic acid copper salt spray test
11.GB/T 12967.3-91 CASS Accelerated acetic acid copper salt spray test
2. According to CNS JIS ASTM GB2423.19 specifications, can be set constant temperature to control
(A) Salt spray test: NSS, ACSS
1. testing room : 35 ℃ ± 1 ℃
2. saturated air barrels : 47 ℃ ± 1 ℃
(B) anti-corrosion test: CASS
1. testing room: 50 ℃ ± 1 ℃
2. saturated air barrels: 63 ℃ ± 1 ℃
3. Aair supply system: air pressure 1Kg/cm2 Two-stage adjustments (coarse / fine-tuning).
(A) the first paragraph for the rough adjustment 2-2.5Kg/cm2, the second paragraph to fine-tune 1Kg/cm2.
(B) Testing configuration is switch connector designed for SO2.
4. Spray form:
(A) Using Bo Nute principle to draw brine and then saline spray, atomization uniform, non-blocking and crystallization, so that ensure continuous spraying.
(B) Nozzle: The nozzle is made of special glass, adjust spray volume and spray angle.
(C) spray volume: Adjustable 1 ~ 2ml (80cm2/hr) (average of 16-hour volume).
5. Heating devices:
By direct heating, warming up faster and reduction of standby time, when the temperature arrives automatically switch ON / OFF, make temperature accuracy, low power consumption (heating tube is made of titanium alloy).
6.The control system:
(A) testing room temperature controller is the digital micro-computer products 0-99.9 ℃, liquid crystal digital display with PID automatic calculation, the control error is ± 0.3 ℃ (YANG MING6802) 1 pcs.
(B) saturated air barrels controller 0 ~ 99.9 ℃, liquid crystal digital display with PID automatic calculation, the control error is ± 0.3 ℃ (YANG MING6802) 1 pcs.
(C) safe temperature controller of heat expansion of the liquid tank 30 ~ 110 ℃ (Italy) 1 pcs.
(D) safe temperature controller of expansion of the saturated air barrel : 30 ~ 110 ℃ (Italy) 1 pcs.
(E) digital time controller 9.9s ~ 9990hr (Taiwan) 1 pcs.
(F) timer 0 ~ 9999hr (Taiwan Anliang) 1 pcs.
(G) buckle switch, continuous buckling 20000 times.
(H) 60 type, 90 type for manual flip, 120, 160, 200 type for the pneumatic cylinde automatic opening and closing.
(J) pressure gauge, (Taiwan B card).
(K) fixture bleaker (YANG MING).
(L) electromagnetic valve; (KSD).
(M) regulating valve (YIHUA).
(N) bleaker (Omron).
7.Add water systems:
Using automatic water replenishment system, automatic replenishment when the water level is too low.
8.Safe protective device:
(A) low water level, automatically cut off power supply.
(B) over-temperature, automatic cut off the power supply.
(C) attached to the safe warning light device.
Send Inquiry to This Supplier
You May Also Like
-
Xenon Arc Lamp Testing Machine Weatherometer Accelerated Weathering TesterUS$ 8000 - 12000MOQ: 1 Set
-
2 Box Hot and Cold Extreme Temperature Impact TesterUS$ 15000 - 18000MOQ: 1 Set
-
3-slot High and Low Temperature Impact Testing MachineUS$ 14500 - 16500MOQ: 1 Set
-
Ultraviolet Radiation Sterilization Chamber UV Light SterilizerUS$ 1800 - 4000MOQ: 1 Set
-
IP X3 X4 Metal Fittings Waterproof Rain Spray Test MachineUS$ 3000 - 5000MOQ: 1 Set
-
IPX5 IPX6 High Pressure Water Spray Resistance TesterUS$ 3000 - 5000MOQ: 1 Set
-
ASTM Rubber Plastic Ozone Aging Test Resistance ChamberUS$ 4000 - 8000MOQ: 1 Set
-
IP5X/ IP6X Sand Dust Resistance Test EquipmentUS$ 2500 - 5000MOQ: 1 Set
-
Metal Building Material High and Low Temperature Testing MachineUS$ 2500 - 5000MOQ: 1 Set
-
Programmable Rapid Electronic Connector Temperature Change Test EquipmentUS$ 2500 - 5000MOQ: 1 Set