DW-GC1290 LCD Touch Screen Cheap Gas Chromatograph
| Model# | DW-GC1290 | ||
| Description |
EPC(electronic pneumatic control) 7 inch touch screen display |
||
| Sample Introduction System | sample injector and evaporation chamber | ||
| Column Oven | Temperature range | Ambient temperature +7℃ ~ 420℃ (in 1℃ increment) | |
| Temperature accuracy | ± 0.02℃ | ||
| Cooling time | 350℃~100℃≤3min, 400℃~50℃ in 8-10 min at 25℃ ambient | ||
| Programmed temperature setting | 0.1℃~80℃/min (in 1℃ increment) | ||
| Program ramps | 20 ramps in total (99 ramps available with control workstation) | ||
| Size (L*W*H) | 284*280*241mm(inside) | 340*345*281mm(outside) | |
|
Flame Ionization Detector (FID) |
Detection limit | ≤8×10/12g/s (n-hexadecane) | |
| Drift | ≤1.5×1//13A/h | ||
| Noise | ≤3×10/14A | ||
| Linearity range | ≥106 | ||
|
Flame Photometric Detector (FPD) |
Detection limit | ≤8×10/13g/s(P) ; ≤8×10/11g/s(S) | |
| Drift | ≤2×10/11A/30min | ||
| Baseline noise | ≤5×10/12A | ||
|
Nitrogen-Phosphorus Detector (NPD) |
Detection limit |
≤5×10/12g/s(N) (Azobenzene) ≤5×10/13g/s(P) (Malathion) |
|
Features:
. Control system: designed for monitoring and controlling the instrument via the computer.
. Column Compartment/oven with superior thermal performance, multistage (20 ramps) programmed temperature control function. (supported by “control system”)
. Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
. Column oven supports quick heat-up and rapid cool-down with automated back-door opening.
. Flexible sample introduction system: 2 sample injectors could be installed and operated simultaneously with independent temperature control.
. High sensibility and stability detector.
. 2 independent and analog signals output.
. M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
Electronic pneumatics control system
Flow rate: 200ml/min (N2), 1000ml/min (He)
Flow rate accuracy: ±5%
Flow rate repeatability: ±0.35%
Split ratio: 0-5000(He), 0-1000(N2)
Inlet temperature: 0-420℃
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/ FPD/ NPD




Send Inquiry to This Supplier
You May Also Like
-
Honeywell SiF4 Gas Detector MIDAS-E-HFX MIDAS-K-HFX Original and NewNegotiableMOQ: 1 Piece
-
LD 200 Halogen Gas Freon CFCs HCFCs HFCS HFO Refrigerant Leak Detector LD-200NegotiableMOQ: 1
-
High Quality Gas Leak DetectorNegotiableMOQ: 1 Piece
-
Dual Digital Breath Alcohol TesterNegotiableMOQ: 2000 Pieces
-
Sulfur Hexafluoride SF6 Recycling Device With Function of SF6 FillingUS$ 2,000 - 50,000MOQ: 1 Set
-
Factory Offer NO Gas Detector OEM Gas DetectorUS$ 400 - 600MOQ: 10 Sets
-
BrACAudit Panther-3 (with Camera, Built-in Printer) Breath Alcohol AnalyzerUS$ 568.00 - 568.00MOQ: 3 Pieces
-
CALIBRE Ethylene Golycol Tester Antifreeze TesterNegotiableMOQ: 1020 Pieces
-
Industria Online Portable Gas TesterUS$ 250 - 300MOQ: 1 Unit
-
Professional Sophisticated Automotive Exhaust Gas Analyzer Supplier's ChoiceUS$ 1,830 - 2,100MOQ: 1 Unit