US$ 2,340 - 2,415 MOQ: 1 Unit
Key Specifications
Get Latest Price
Brand Name:
Lanphan
Place of Origin:
Henan, China
Type:
Water-Cooled
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai Tianjin Qingdao
Delivery Detail:
Delivery time depends on order quantity.
Brand Name Lanphan
Place of Origin Henan, China
Type Water-Cooled
Certification CE, ROHS
Warranty 1 Year
Voltage 220w
Condition New

Laboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump

The capacity of our refrigeration pump can be 5L-500L
Temperature ranges from room temperature to -120 degrees

Product Description

Laboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump

The application of Low temperature circulating pump:DLSB low temperature pump adopts mechanical refrigeration low temperature circulating equipment and provide constant current and constant voltage circulating liquid to meet the requirement of the decreasing instrument (electric microscope, electricity probe,x-ray machine,laser reactor and accelerator) so as to guarantee the required working temperature
The machine is an essential to make sure the normal working condition for the device adopting constant current and constant pressure to cool in the condition of lacking water place ,bad quality of water and higher temperature.It can provide low temperature liquid to have multiple function of chemical reaction and medicine storage collocated with rotary evaporator,vacuum drying oven,circulating water multiple pump,magnetic force stirrer.It is especially used for different kinds of chemical biology ,physical lab which needed low temperature.It is the essential lab instrument for pharmacy,food industry,metallurgical industry and college scientific research.

Laboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump

type DLSB 50L-30℃ DLSB 50L-30℃
Tank volume (L) 59.31 59.31
lowest no-load temperature(℃) -30
Using temperature range (℃) room temperature—-30
best temperature range(℃) ≤25
Environmental relative humidity (%) ≤70
Working power supply (V/HZ) single phase 220V 50HZ three phase 380/50
temperature display mode liquid crystal
temperature stability(℃) ±2
Sensor index Pt100
Instrument adjusting range (℃) ±150
set way Arbitrary adjustment of Settings in the range of use
safety protection delay,leakage,over current,over heat
  10℃ 4190 5475
Output refrigerating capacity(w) 0℃ 3354 4380
  -10℃ 2236 3285
  -20℃ 1397 1190
  -30℃ 559 1095
Total machine power (W) 2930 3850
Machine current (A) 13.8 5.4
refrigerant R404A R404A
  Power(W) 100 100
circulating pump Flow rate(L/min) 25 25
  lift(M) 7 7
Opening size(mm) 360×360 360×360
 tank shape    
internal diameter and height of liquid storage tank(mm) 390×390×390 390×390×390
overall appearance size(mm) 760×615×1130 760×615×1130
machine weight(kg) 97 97

 

Laboratory Low Temp Cooling Liquid 50L Circulation Coolant PumpLaboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump

 

Turn on and off:
The right turn to turn on the machine: Add the appropriate refrigerating medium—connect the power with the special power supply—turn off the circulation switch—press the power button—open the circulation switch—open the refrigerator switch—open the cooling equipment
The right turn to turn off the machine.Turn off the cooling equipment—turn off the refrigerator switch—turn off the circulation switch(stirring switch)—turn off the outlet valve(or discharge the cooling medium)—turn off the power supply —disconnect circuit breaker—disconnect the power line from the power supply—clean the equipment.
Corollary Equipment

Laboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump

Related Products

Laboratory Low Temp Cooling Liquid 50L Circulation Coolant PumpLaboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump

The capacity of our refrigeration pump can be 5L-500L
Temperature ranges  from room temperature to -120 degrees

Company Information
Laboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump

Laboratory Low Temp Cooling Liquid 50L Circulation Coolant PumpLaboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump

Laboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump

Laboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump

Laboratory Low Temp Cooling Liquid 50L Circulation Coolant Pump Contact us For more details about price, packing, shipping and discount. Tel: 86-371-67447999
Web:
Address: Jianshe Road, Zhongyuan District, Zhengzhou, Henan, China

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Distributor/Wholesaler
Year Established
2000
Annual Export Value
US$5 Million - US$10 Million
Main Markets
Southern Europe, Northern Europe, Central America, Western Europe, Eastern Asia, Mid East, Oceania, Africa, Southeast Asia, Eastern Europe, South America, North America