Type Other

I. Introduction

SS-300-NH3 Extractive Laser Analysis System adopts TDLAS Tunable diode laser absorption spectroscope to measure HF concentration. It adopts special heated sampling probe which is able to work in high-temperature and high dust conditions, and hot & wet sampling system with little gas loss caused by gas condensing. Compare in-situ type gas analyzer, the extractive system has the advantages of no requirement of installation conditions, easy maintenance, little pollution to mirror, suitable for dirty sampling point with high dust.
 

II. Applications field

It is used to monitor NH3 after SNR or SCNR process in the waste incineration plant, power plant and so on.

 

III. Specifications

  Monitoring place

Gas component

Measurement range

SNR or SCNR stack outlet

NH3

0-20ppm(can be customize)

1. Measurement principleTDLAS

2. Sampling methodHot & Wet extractive sampling

3. Sampling pipe materialSUS316

4. Heated tube diameter: ø8×6

5. Power supplyAC220V±10% 50/60Hz

6. Power consumptionMax 2000W+50W*heated tube length

7. Calibration periodeach 6 months

8. Analogue output4 - 20mA

9. Max load4 - 20mA 550Ω

10. Alarm outputgas temperature alarm, gas low pressure, gas over pressure alarm.

                  

IV. Features

1. Extractive sampling method

2. Easy calibration and calibration

3. Adopts TLDAS principle, little cross-sensitivity,

4. Laser detector with long lifespan

5. Optional sampling probe calibration function.

6. IP 65 protection class.

7. Adopts hot and wet sampling and gas pretreatment with temperature 190, preventing HCL gas loss by condensation.

8. Sampling probe with purging function.

9. With lens blow up function, to prevent it dewing.


Product Tags: TDLAS , HF analysis system , gas monitoring system

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location
Changsha, Hunan, China

Recommended Categories

Explore top categories and find suppliers for your specific needs