Digital Display Plastic Thermal Deformation Vicat Softening Point Tester For Plastic

Introduction:

1) Softening Point Testing Machine (VST) is mainly used for deformation temperature and Vicat softening point test for horniness pipes and tubes materials. It\'s suitable to measure the HDT and VICAT character of plastics, rubber, nylon, electrical insulation materials etc., widely used in production, research, 

inspection department and institute for educations. 

2) The tester is using PLC programmable controller for temperature control LCD display operation.This is

the product of simple operation, easy to use, stable performance, high precision products, and in the 

process of test can be real monitoring test temperature and deformation; At the end of the test system 

automatically stop heating, the machine can set the target temperature with temperature protection 

function.

3) With the sample holder lifting function so that the sample holder can be adjusted to the proper 

position at the beginning and the end of the test. Negative pressure induced air function without oil 

absorption, not smoke in the process of test, to ensure the test environment is clean.With rapid cooling 

device.

Conform with standard ISO075, ISO306, GB/T8802,GB/T1633,GB/T1634 etc..

Characteristic:

1, The tester is floor model, with beautiful appearance and stable performance, high accuracy, easy to use. 
2, Three-way displacement sensor to measure the deformation. 
3, Digital display temperature and displacement. 

Specifications:

1) temperature control range: environment temperature~300℃

2) Heating rate: (120±10) ℃/h (12±1) ℃/6min

                        (50±5) ℃/h (5±0.5) ℃/6min

3) Temperature display error: 0.1℃

4) Temperature control precision: ±0.5℃

5) Maximum deformation display error: ±0.01mm

6) Deformation measurement range: 0—1.5mm

7) Sample holder number: 3 

8) Heating medium: methyl silicone oil or transformer oil

9) cooling mode: nature cooling beyond 150, water cooling or nature cooling below 150

10) Heating power: 4 kw, 220V 50HZ

11) Instrument size: 540mm×520mm×970mm

12) Rod load and tray quality: 68 g

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Dongying, Shandong, China

Recommended Categories

Explore top categories and find suppliers for your specific needs