Home > Products > Pressure Composition Isotherm Analyzer > high pressure volumetric analyzer
high pressure volumetric analyzer
- 30 Set / Sets per Month
- T/T L/C D/P D/A
- 7 days
You May Like
-
high pressure gas sorption measurement
-
porosimetry measurement, porosimetry ppt, porosimetry BET
-
high pressure hydrogen adsorption apparatus
-
high pressure hydrogen adsorption in the zeolites
-
high pressure CH4 and CO2 sorption isotherms
-
high pressure methane adsorption, high pressure methane and carbon dioxide adsorption
Product Details
Brand Name | Gold APP Instruments | Place of Origin | China | |
Model Number | H-Sorb 2600 |
Product Description
H-Sorb 2600 high pressure gas adsorption volumetric principle analyzer introduction
Gas sorption analysis is important in many fields of materials, such as energy storage materials, improved catalysts for petrochemical processing, advanced pharmaceuticals and food industries. At present, there is tremendous interest in the development of innovative materials for the transition to renewable energy. The science of gas sorption has become particularly critical in the advancement of materials for storing fuel gases such as hydrogen or natural gas, as well as for sequestration of greenhouse gases.
The H-Sorb 2600 high pressure gas sorption analyzer adopts the volumetric technique principle which consists of dosing a known amount of gas adsorptive into measurement tubes where lying samples (such as zeolites, carbon nanotubes, rocks, catalysts, activated carbons, molecular sieve, hydrides etc. ) to be analyzed. When samples reach equilibrium with the adsorbate gas (such as hydrogen, methane, carbon dioxide, nitrogen, argon, krypton etc.), detailed and comprehensive final equilibrium pressures will be recorded automated by Gold APP Instruments company dedicated and patented software. These data are used to calculate the quantity of gas adsorbed by samples. This measurement procedure automatically repeated by software under given temperature and pressure intervals until finalized the maximum preselected pressure. Finally, each of the equilibrium points’ volume adsorbed, equilibrium pressure, absolute pressure etc. data are plotted to produce the isotherm. By using the isotherm data, operators can calculate further more information such as Langmuir fitting isotherm, the adsorption rate curve, PCT (pressure-composition-temperature) or PCI (pressure-composition-isotherm) curve etc.
Pressure-Composition Isotherms (PCI) and Pressure-Composition Temperature (PCT) is one of the most informative sorption measurements. The result is a plot of the equilibrium absorbed gas concentration in the material as a function of pressure and temperature.
Gold APP Instruments high pressure and high temperature gas sorption analyzer H-Sorb 2600 adopts static volumetric principle to determine adsorption and desorption isotherms under high pressure (atmospheric to 200Bar) and high temperature (atmospheric to 500℃) with a stainless steel VCR manifolds system, fully automated operation can control system and multi calculation methods, all these guarantee H-Sorb 2600 to produce a highly repeatibility and highly precision analysis data.
H-Sorb 2600 high pressure gas adsorption volumetric principle analyzer parameters
Analysis Method: static volumetric principle, high pressure gas sorption principle
Versatility: adsorption/desorption isotherms measurement (atmospheric to 500℃), Gibbs supercritical adsorption measurement
Data Reduction: Langmuir model regression isotherm, PCT(Pressure-Composition-Temperature) or PCI (Pressure-Composition-Isotherm) diagram/curve/isotherm measurement, Langmuir maximum adsorption constant L and adsorption pressure constant B measurement; Langmuir correction model loading-ratio correlation regression (LCR) isotherm; Ono-Kondo (OK) lattice model isotherm regression; adsorptive gas density and vapor-liquid equilibrium accuracy calculation under different pressures and temperatures
Measuring Ranges: continuous adsorption and desorption measurement from atmospheric to 200Bar pressure
Accuracy: repeatability errors <3%
Temperature Range: cryogenic to 500℃, accuracy±0.1℃
Sample Ports: two samples analyzing and two degassing, stainless-steel micro welding sample cells, software integrated temperature PID adjustment
Transducer Accuracy: imported high precision transmitter, accuracy can reach 0.05% of F.S. (full-scale), long-duration usage stability is 0.025% of F.S.
Ultimate Vacuum: 4x10-2 Pa (3x10-4 Torr), molecular pump system (1x10-6 Pa) is optional
Adsorbate Gas: high purity nitrogen, CO2 or others (Ar, Kr, H2, CH4 etc.)
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Contact Us
- Gold APP Instruments Corporation China
- Contact nameGoldAPP Instruments Chat Now
- Phone86-10-82132122
- AddressFloor 6th, Tianli Building, No. 56th, Zhichun Rd., Haidian Dist, Beijing 100098, Liaocheng, Shandong
Product Categories
New Products
-
high pressure methane adsorption in the metal-organic-frameworks
-
hydrogen and methane adsorption in metal-organic frameworks
-
High-Pressure Adsorption of Methane and Ethane in Activated Carbon and Carbon Fibers
-
adsorption in porous meterials at high pressure
-
high pressure adsorption equilibria of methane and carbon dioxide
-
high-throughput single point BET analyzer
-
Brunauer, Emmett and Teller (BET) Theory Apparatus
-
V-Sorb 2800S specific surface area analyser for zeolite test
-
multi point BET surface area analyzer
-
helium pycnometer density analyzer supplier
-
Gas Pycnometer true density analyzer
-
BET surface area analyzer
-
high pressure volumetric analyzer
-
surface area and pore size analyzer
-
static volumetric principle to determine surface area
-
BJH pore size distribution measurement apparatus
-
Langmuir surface area analyzer by static volumetric method
-
Langmuir surface area analyzer
-
BET specific surface area analyzer
-
high pressure gas sorption analyzer
-
gas pycnometer helium true density analyser by gas displacement principle
-
high pressure gas adsorption analyser by volumetric principle
-
surface area and volume measurement analyser for nanomaterials
-
helium pycnometry true density analyzer
Popular Searches
- Carbon Analyzers
- sulfur analyzer
- element analyzer
- infrared carbon sulfur analyzer
- Carbon Sulfur Analyzer
- Total Organic Carbon Analyzer
- Carbon Sulphur Analyzer
- Silicone Analyzer
- Carbon Silicone Analyzer
- Metal Analyzer
- bet surface area analyzer
- food safety testing equipment
- food safety tester
- fat analyzer
- carbon analyzer
- diffraction
- Infrared Analyzer
- Content Analyzer
- Soil Tester
- Soil Ph Analyzer
- Metal Element Analyzer
- protein analyzer
- plant leaf meter
- Oil Moisture Sensor
- steel analyzer
- Sulfur Content Analyzer
- soil nutrient tester
- Soil Fertilizer Nutrient Tester
- Npk Soil Nutrient Tester
- particle size analyzer
Recommended Products
- ANEMOMETER DB22-236C
- YS264 type sanitary napkin absorption rate tester
- WSB-3A type whiteness meter
- Fully Automated ELISA Analyzer Newton Series
- SEAZENE Auto Blood Grouping System
- Side Pressure Tensimeter DB25-204SPT-5KN-100KN
- Belt Tension Tester DB22-280S
- Optometer Illuminometer LX-1261R
- GB/T 11007 Automatic Electrolyte Conductivity Tester
- ASTM D4603 Viscosity of Polyethylene Terephthalate PET Tester Glass Capillary Viscometer Method
- ASTM D6594 Diesel Engine Oil Corrosion Performance Tester at 135℃
- ASTM D97 D2500 Two-Slot Four-Hole Multi-Function Pour Point and Cloud Point Tester Oil Bath
Find Similar Products By Category
- Instruments & Meters > Analysis Instrument > Other Analysis Instruments
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
GoldAPP Instruments
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile