Home > Health & Medicine > Medical Supply > Disposable Medical Supplies > Portable Patient ECG Monitor Medical Equipment 8.4 Inch TFT With 8 Channel Waves CE

Portable Patient ECG Monitor Medical Equipment 8.4 Inch TFT With 8 Channel Waves CE

Portable Patient ECG Monitor Medical Equipment 8.4 Inch TFT With 8 Channel Waves CE photo-1
Negotiable MOQ: 1 Kilogram (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Brand Name:
hb
Place of Origin:
China
Model Number:
PM001
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Brand Name hb
Place of Origin China
Model Number PM001
Delivery Time:7-15days
Certification:ISO

Portable Patient ECG Monitor medical equipment 8.4 inch TFT with 8 channel waves CE 1. Detailed Product Description: 1.8.4 inch color TFT display 2.Support 8 channel waves 3.Unique human voice alarm. 4.CE approved 5.18 months guarantee 2. Feature: 1 8” color TFT display, support 8 channel waves, 6 parameters. 2 Unique human voice alarm. 3 Rich screen layouts: Standard, big font, trend table, NIBP trend, ECG full lead, OxyCRG.. 4 Powerful storage: maximum 720 hour graphic and tabular trends of all parameters, up to 10000 NIBP review, 200 alarm event review, 2 hours of all waveforms. 5 System software can be upgraded through network. 6 Standard configuration: ECG, RESP, TEMP, NIBP, SpO2 7 Optional: Recorder, VGA. 3.Specification: Screen Size:8.4 inch ECG: Lead mode:I II III, AVR.VL.AVF.V GAIN:*0.25.*0.5.*1.*2(mm/mV) Hear rate:15-300 bpm(adult) 15-350bpm(pediatric) Resolution:1bpm Accuracy:+-1% Bandwidth: Diagnostic:0.05-130Hz Monitor:0.5-40Hz Surgery:1-20Hz Sweep speed:12.5mms, 25mm/s, 50mm/s Pacemaker rejection:Yes ST measurement Range:-2.0+-2.0mv Accuracy:+-0.02mv or +-10% which is greater Spo2: Measure range:0-100% Resolution:1% Accuracy:+-2% Resolution:1bpm Accuracy:+-3bpm NIBP: Work mode: manual, automatic, continuous Unit: mmHg, Kpa Measure range: adult: SYS:40-280mmhg DIA:10-220mmhg MEAN:20-240mmhg Pediatric:SYS:40-220mmhg DIA:10-160mmhg MEAN:20-170mmhg Neonatal:SYS:40-135mmhg DIA:10-100mmhg MEAN:20-100mmhg Resolution:1mmhg Accuracy: max mean error:+-5mmhg; max standard deviation:8mmhg Overpressure protection:0-300mmhg Degree of protection:BF.CF RESP: Measure range:Adult:0-120rpm pediatric.neonatal 0-150rpm Resolution:1 rpm Accuracy:+-2% TEMP: Channels:2 Measure range:0-50°c Resolution:0.1°c Accuracy:+-0.1°c(25-45c°) Recorder(optinal): Width:48mm Speed:25-50mm Channels:2
payment:TT, West Un
minimum order:

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Zaozhuang, Shandong, China

Recommended Categories

Explore top categories and find suppliers for your specific needs