Home > Industrial Equipment & Components > Refrigeration Equipment > Industrial Chiller > Laboratory Use Recirculating Water Chiller

Laboratory Use Recirculating Water Chiller

Laboratory Use Recirculating Water Chiller photo-1
Laboratory Use Recirculating Water Chiller photo-2
Laboratory Use Recirculating Water Chiller photo-3
Laboratory Use Recirculating Water Chiller photo-4
Laboratory Use Recirculating Water Chiller photo-5
Laboratory Use Recirculating Water Chiller photo-6
US$ 100 - 766 MOQ: 1 Set
Key Specifications
Get Latest Price
Condition:
compression cooling
Type:
Water-Cooled
Place of Origin:
Henan, China
Payment & Shipping
Payment Methods:
Port of Shipment:
Qingdao Dalian Tianjin Shanghai
Delivery Detail:
Delivery time depends on order quantity.
Condition compression cooling
Type Water-Cooled
Place of Origin Henan, China
Brand Name ZZKD
Model Number DLSB-5/10
Cooling Capability(kw) 8.42~142KW
Voltage 220V
Dimension(L*W*H) 500*400*800
Weight 40KG
Certification CE, Other, CE, ISO
Warranty one year
After-sales Service Provided Engineers available to service machinery overseas

Laboratory use Recirculating Water Chiller

Specifications

1.Recirculating water chiller

2.Corrosion-resisting materials 
3.Energy-saving 
4.different size different temperature 

Laboratory Use Recirculating Water ChillerLaboratory Use Recirculating Water Chiller

Laboratory Use Recirculating Water Chiller

 

Laboratory Use Recirculating Water ChillerLaboratory Use Recirculating Water Chiller  

Product Description

 

1.Brief introduction of recirculating water chiller

Low-temperature circulating pump also know as Low temperature cooling water 

liquid circulation pump. This device adopt mechanical refrigeration, the main function is provide low temperature liquid, low temperature water bath . It can also connect with rotary evaporator, vacuum freeze drying oven , cycle water vacuum pump , magnetic stirrer and so on , to achieve the chemical reaction or drug store under low temperature condition.

Large cryogenic cooling liquid circulating pump is constant flow, constant voltage. Used for purification of high purity metals, rare element, environment experiment and magnetron sputtering, vacuum coating and other large equipment, and also can meet the cooling demand of electron microscopy, electron probe, ultra high vacuum sputtering apparatus, X-ray machine, laser and accelerate the electric light 

those high value equipment. Cryogenic cooling liquid circulating pump is particularly suitable for the chemistry, biology, physics laboratory work under normal conditions or need to maintain a low temperature. It is a necessary lab equipment for medicine, chemical industry, food industry, metallurgical industry, universities, scientific research, genetic engineering, polymer engineering etc. (Can be customized large capacity according to user needs ).

Laboratory Use Recirculating Water Chiller

Laboratory Use Recirculating Water Chiller

 

2.Product features of recirculating water chiller

(1)Air-cooled and hermetically sealed compressor units (import) with dependable 

quality; 

(2)The dedicated and high-quality relays, protective devices and capacitors of 

the refrigerating units; 

(3)Digital Read Out of temperature and microprocessor controller for temperature, simple and easier to see; 

(4)It can be matched with a variety of instruments (rotary evaporators, fermentation tanks, chemical reactors, freeze-drying equipments, pharmaceutical reactors, etc.);

(5)Bigger cooling capacity and faster cooling speed, which have greatly improved the working efficiency;

(6)It can effectively ensure the normal use of all kinds of precision instruments under the working conditions such as lacking water, the poor quality,pressure and temperature of water, and high temperature;

(7)The flow of circulating pump can be either adjusted or customized, which has greatly met the actual needs of different customers;

(8) All models of this machine can be matched reasonably between the low temperature and the cooling capacity or capacity basing on the requirements of customers. 

Technical Parameters

Keda low-temperature pump types classification

According to the volume of cryogenic cooling bath circulation pump divided into : 5L,10L,20L,30L,40L,50L,60L,80L,100L.

Each volume according to the lowest temperature can divide into : -10℃,-20℃,-25℃ ,-30℃,-40℃,-60℃, -80℃,-120℃.

 

3.Technical Parameter of recirculating water chiller

Model

Bath volume

(L)

Lowest temp    (°C)

Cooling capacity (W)

Flow  (L/min)

Lift

(m)

 Coolant temp  (°C)

Temp fluctuation (°C)

Power Supply

(V/Hz)

Ambient temp

(°C)

Ambient humidity

(%)

DLSB-5/10

5

-15

1328-319

20

4-6

-10

±0.2

220 50/60

25

   60-80  Ventilation

 

DLSB-5/20

-24

1328-319

-20

220 50/60

DLSB-5/25

-27

1894-447

-25

220 50/60

DLSB-5/30

-33

2733-627

-30

220 50/60

DLSB-5/40

-42

2036-602

-40

220 50/60

DLSB-5/60

-62

2036-330

-60

220/380

DLSB-5/80

-82

2036-180

-80

220/380

DLSB-5/120

-123

3888-160

-120

220/380

 

4.Note of recirculating water chiller

Please read it carefully before using the instrument. 

1, The machine's power standard is 220 v, should be equipped with reasonable grounding system and the safety of the standard three pole socket.

2, Before use, please put into the liquid medium (water, alcohol, antifreeze can also be), medium level should not lower than cold tube and 20 mm below the workbench is advisable. Don't let sand , acid-base class material or debris into the cooling system or the circulation pump, to prevent clogging or corrosion liner and coil.

3, Recurring observe the slot liquid level height, when the liquid level is too low, should be timely to add liquid medium.

4, When pump working temperature is lower, should pay attention not to open the cover. Never put your hand into the groove, to prevent frostbite. 

5, The Pump working environment, temperature <= 25 ° C , humidity <=  60 ℃, 

no obstacles in the instrument around 300 mm. Indoor open flame is strictly prohibited. 

6, When the liquid outer loop, the client shall pay special attention to the robustness of the out pipe joint, fight off, in order to avoid liquid leakage. 

7, After use, all switch should be closed and cut off power supply. 

8, The instrument should be regular cleaning, if the pump unused for a long time, you should put out the medium, and deep clean, maintain a clean and tidy work in mesa and the operation panel.

9, Don't try to open and repair equipment personal, any question, just make a call !

Packaging & Shipping

Packaging of recirculating water chiller
-Export wooden or carton packing
-Both neutral and customized packaging can be available

Shipping of recirculating water chiller
-We can ship the goods to you per the below shipping methods and you can choose the appropriate one
based on your timeline and budget. Also you can definitely choose to use your own shipping agent.

 

Our Services

Laboratory Use Recirculating Water Chiller

 

Company Information

Keda Machinery and Instrument Equipment Co.,Ltd.Our company sells recycled water vacuum pumps, rotary evaporators,thermostatic magnetic stirrers, glass reactors, low temperature cooling circulating pumps, oil baths, electric mixers, ovens, water baths, freeze-drying machines, electronic energy-saving temperature control devices, smart thermostats and electric experimental equipment sets.

With solid strength, reasonable prices and excellent services, our company has established long-term cooperative relationships with a number of enterprises.

Laboratory Use Recirculating Water Chiller

Laboratory Use Recirculating Water Chiller

FAQ

1 . How can I choose a reasonable model from so many models ?

We can supply temperature range from - 10 to -120 Celsius degree; Capacity from 5L-100L.

 

2. OEM is ok?

Yes, we can do artwork including printing, logo etc. for you, if you provide us the content and tell us where to put. 

 

3. My location voltage is 110V, how can we handle this ?

Don’t worry! you can equipped with a voltage regulator, or , we can customized 110V for you (quantity exceed 10 sets ).

 

4. What’s the transportation mode you can choose?

For small orders, we will send the goods by International Express like Fedex, DHL, TNT or UPS. Usually it takes 3-7 work days to arrive. If big quantity we will ship by Ocean transportation, it takes one month to arrive.Iff urgent, you can select shipping by Air, but freight charge will be more expensive than sea transporation.

 

 

Hot line:(86)0371-86126825(24h)
Mobile phone:13783441102
Website:

For more details about recirculating water chiller please contact us we will reply to you within 24 hours!

 Laboratory Use Recirculating Water ChillerLaboratory Use Recirculating Water Chiller

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2009
Factory Size
Below 1,000 square meters
Total Employees
11 - 50 People