Low Temperature Recirculating Chiller Lab

Low Temperature Recirculating Chiller Lab photo-1
Low Temperature Recirculating Chiller Lab photo-2
Low Temperature Recirculating Chiller Lab photo-3
Low Temperature Recirculating Chiller Lab photo-4
Low Temperature Recirculating Chiller Lab photo-5
Low Temperature Recirculating Chiller Lab photo-6
US$ 950 - 2,100 MOQ: 1 Set
Key Specifications
Get Latest Price
Condition:
compression cooling
Type:
Water-Cooled
Place of Origin:
Henan, China
Payment & Shipping
Payment Methods:
Port of Shipment:
Qingdao Dalian Tianjin Shanghai
Delivery Detail:
Delivery time depends on order quantity.
Condition compression cooling
Type Water-Cooled
Place of Origin Henan, China
Brand Name ZZKD
Model Number DLSB Series
Cooling Capability(kw) 3.75KW
Voltage 220V
Dimension(L*W*H) 900*750*1200
Weight 85KG
Certification CE
Warranty one year
After-sales Service Provided Engineers available to service machinery overseas

Low Temperature Recirculating Chiller Lab

Specifications

1.Recirculating chiller lab

2.Corrosion-resisting materials 
3.Energy-saving 
4.different size different temperature 

 

 Low Temperature Recirculating Chiller Lab

Low Temperature Recirculating Chiller Lab

Low Temperature Recirculating Chiller Lab

Low Temperature Recirculating Chiller Lab

 

Product Description

 

Brief introduction of recirculating chiller lab

Low-temperature circulating pump also know as Low temperature cooling water /

 liquid circulation pump. This device adopt mechanical refrigeration, the main function is provide low temperature liquid, low temperature water bath . It can also connect with rotary evaporator, vacuum freeze drying oven , cycle water vacuum pump , magnetic stirrer and so on , to achieve the chemical reaction or drug store under low temperature condition.

Large cryogenic cooling liquid circulating pump is constant flow, constant voltage. Used for purification of high purity metals, rare element, environment experiment and magnetron sputtering, vacuum coating and other large equipment, and also can meet the cooling demand of electron microscopy, electron probe, ultra high vacuum sputtering apparatus, X-ray machine, laser and accelerate the electric light those high value equipment. Cryogenic cooling liquid circulating pump is particularly suitable for the chemistry, biology, physics laboratory work under normal conditions or need to maintain a low temperature. It is a necessary lab equipment for medicine, chemical industry, food industry, metallurgical industry, universities, scientific research, genetic engineering, polymer engineering and so on . (Can be customized large capacity according to user needs ).

Low Temperature Recirculating Chiller Lab

Low Temperature Recirculating Chiller Lab

 

Product features of recirculating chiller lab

(1)Air-cooled and hermetically sealed compressor units (import) with dependable 

quality; 

(2)The dedicated and high-quality relays, protective devices and capacitors of 

the refrigerating units; 

(3)Digital Read Out of temperature and microprocessor controller for temperature, simple and easier to see; 

(4)It can be matched with a variety of instruments (rotary evaporators, fermentation tanks, chemical reactors, freeze-drying equipments, pharmaceutical reactors, etc.);

(5)Bigger cooling capacity and faster cooling speed, which have greatly improved the working efficiency;

(6)It can effectively ensure the normal use of all kinds of precision instruments under the working conditions such as lacking water, the poor quality,pressure and temperature of water, and high temperature;

(7)The flow of circulating pump can be either adjusted or customized, which has greatly met the actual needs of different customers;

(8) All models of this machine can be matched reasonably between the low temperature and the cooling capacity or capacity basing on the requirements of customers. 

Technical Parameters

Keda low-temperature pump types classification

According to the volume of cryogenic cooling bath circulation pump divided into : 5L,10L,20L,30L,40L,50L,60L,80L,100L.

Each volume according to the lowest temperature can divide into : -10℃,-20℃,-25℃ ,-30℃,-40℃,-60℃, -80℃,-120℃.

 

Technical Parameter of recirculating chiller lab

Low Temperature Recirculating Chiller Lab

Model

Bath volume

(L)

lowest temp    (°C)

Cooling capacity (W)

Flow  (L/min)

Lift

(m)

 coolant temp  (°C)

Temp fluctuation (°C)

Power Supply

(V/Hz)

Ambient temp

(°C)

Ambient humidity

(%)

DLSB-10/10

10

-14

1894-884

20

4-6

-10

±0.2

220

25

60-80  Ventilation

 

DLSB-10/20

-23

2733-813

-20

220

DLSB-10/25

-28

3256-990

-25

220

DLSB-10/30

-32

2036-1022

-30

220

DLSB-10/40

-42

2628-748

-40

220

DLSB-10/60

-62

3679-510

-60

220/380

DLSB-10/80

-82

3679-160

-80

220/380

DLSB-10/120

-122

4997-120

-120

380

 

Note of recirculating chiller lab

Please read it carefully before using the instrument. 

1, The machine's power standard is 220 v, should be equipped with reasonable grounding system and the safety of the standard three pole socket.

2, Before use, please put into the liquid medium (water, alcohol, antifreeze can also be), medium level should not lower than cold tube and 20 mm below the workbench is advisable. Don't let sand , acid-base class material or debris into the cooling system or the circulation pump, to prevent clogging or corrosion liner and coil.

3, Recurring observe the slot liquid level height, when the liquid level is too low, should be timely to add liquid medium.

4, When pump working temperature is lower, should pay attention not to open the cover. Never put your hand into the groove, to prevent frostbite. 

5, The Pump working environment, temperature <= 25 ° C , humidity <=  60 ℃, 

no obstacles in the instrument around 300 mm. Indoor open flame is strictly prohibited. 

6, When the liquid outer loop, the client shall pay special attention to the robustness of the out pipe joint, fight off, in order to avoid liquid leakage. 

7, After use, all switch should be closed and cut off power supply. 

8, The instrument should be regular cleaning, if the pump unused for a long time, you should put out the medium, and deep clean, maintain a clean and tidy work in mesa and the operation panel.

9, Don't try to open and repair equipment personal, any question, just make a call !

 

 

 