Home > Products > XLPE insulated Power Cable > Copper or Aluminum Conductor XLPE PVC Insulated Power Cable 400 mm2 Power Cable for Construction
Copper or Aluminum Conductor XLPE PVC Insulated Power Cable 400 mm2 Power Cable for Construction
- 250000 Meter / Meters per Month
- Shanghai Tianjin Qingdao
- T/T L/C D/P D/A Credit Card PayPal
- Mooring rope cable
- Manufacturer of waterproof gas electric composite cable for air ducts, specialized cable for underwater divers
- The difference between different types of automotive cables and selection advice
- China manufacturer Communicate cable RVVP 4*0.3mm2 for power generation
- IEC62196-2 mode 3 16A single-phase electric vehicle charging process
- Automotive high-voltage cables with protection class IP67 characteristics
Product Details
Place of Origin: | Henan, China | Brand Name: | BEI HOU | Model Number: | YJV |
Insulation Material: | XLPE | Type: | Low Voltage | Application: | Construction |
Conductor Material: | Copper | Jacket: | PVC |
Product Description
Copper or Aluminum Conductor XLPE PVC Insulated Power Cable 400 mm2 Power Cable for Construction
Details:
1.Uo/U: 0.6/1kV
2.Standard: IEC60502, BS7889, GB/T12706
3.Max. working temperature: 90 °C , can be 110 °C as requirement
4.Conductor: Class 1/2 annealed bare copper solid or strands
5.Insulation: XLPE
6.Sheath: PVC
7. Cross section area: 1.5~630mm2
8. Cores: 1~5 cores,3+1,4+1,3+2
9. Packing:Wooden drum or as requirement
10.Certification : ISO9001/ISO14001/OHSAS18001/CCC/CE/CB
11.Remark: Flame retardant,fire resistance,low smoking and Halogen free,or other property can be avaliable
Application:
Power cable is used to transmit and distribute electric power and often used to underground distribution network of cities, outlet line of power station, internal power supply for industrial and mining enterprises and underwater transmission line across rivers or seas.
Characteristics:
1. Rated power-frequency voltage: 0.6/1KV.
2. The permissible highest of long-time working temperature of cable conductors is 90oC.
3. The highest temperature of cable conductors should not beyond 250oC in short circuit condition( the longest duration of time do not exceed 5 seconds).
4. The environmental temperature for cable laying is not below 0oC.
5. The carve radius of cables should not less than 20 times of cable outer diameter.
Technical data:
Nominal Cross sectional area of Conductor (mm2)
| Insulation Thickness (mm) | Sheath Thickness (mm) | Approx. Overall Diameter of cable (mm) | Approx. Weight of Cable (Kg/km)
| D.C resistance of Conductor (ohm/km) | Testing Voltage A.C. | Current rating | |||||
In air(A) | Direct in Soil(A) | |||||||||||
Cu | Al | Cu | Al | (Kv/5min) | Cu | Al | A | Al | ||||
1x1.5 | 0.7 | 1.5 | 6 | 53 | - | ≤12.1 | - | 3.5 | 25 | - | 35 | - |
1x1.5 | 07 | 1.5 | 6 | 68 | 53 | ≤7.41 | ≤12.1 | 3.5 | 30 | 25 | 45 | 35 |
1x4 | 0.7 | 1.5 | 7 | 87 | 64 | ≤4.61 | ≤7.41 | 3.5 | 45 | 35 | 60 | 50 |
1x6 | 0.7 | 1.5 | 7 | 110 | 73 | ≤3.08 | ≤4.61 | 3.5 | 55 | 45 | 70 | 55 |
1x10 | 0.7 | 1.5 | 8 | 155 | 95 | ≤1.83 | ≤3.08 | 3.5 | 140 | 115 | 160 | 130 |
1x16 | 0.7 | 1.5 | 9 | 220 | 120 | ≤1.15 | ≤1.91 | 3.5 | 100 | 80 | 125 | 100 |
1x25 | 0.9 | 1.5 | 10 | 345 | 190 | ≤0.727 | ≤1.20 | 3.5 | 140 | 115 | 160 | 130 |
1x35 | 0.9 | 1.5 | 12 | 424 | 207 | ≤0.524 | ≤0.868 | 3.5 | 175 | 140 | 190 | 150 |
1x50 | 1.0 | 1.5 | 13 | 555 | 245 | ≤0.387 | ≤0.641 | 3.5 | 210 | 170 | 225 | 180 |
1x70 | 1.1 | 1.5 | 14 | 770 | 336 | ≤0.268 | ≤0.443 | 3.5 | 270 | 215 | 280 | 225 |
1x95 | 1.1 | 1.5 | 16 | 1040 | 455 | ≤0.193 | ≤0.320 | 3.5 | 340 | 275 | 335 | 270 |
1x120 | 1.2 | 1.5 | 18 | 1290 | 550 | ≤0.153 | ≤0.253 | 3.5 | 400 | 320 | 380 | 203 |
1x150 | 1.4 | 2.0 | 21 | 1590 | 650 | ≤0.124 | ≤0.206 | 3.5 | 460 | 370 | 425 | 340 |
1x185 | 1.6 | 2.0 | 23 | 1944 | 804 | ≤0.0991 | ≤0.164 | 3.5 | 530 | 415 | 480 | 375 |
1x240 | 1.7 | 2.0 | 25 | 2510 | 1021 | ≤0.0754 | ≤0.125 | 3.5 | 625 | 490 | 555 | 435 |
1x300 | 1.8 | 2.0 | 34 | 3042 | 1160 | ≤0.0601 | ≤0.100 | 3.5 | 795 | 615 | 910 | 710 |
1x400 | 2.0 | 2.1 | 37 | 3869 | 1469 | ≤0.0470 | ≤0.0778 | 3.5 | 930 | 730 | 1050 | 820 |
1x500 | 2.2 | 2.2 | 41 | 4910 | 1829 | ≤0.0366 | ≤0.0605 | 3.5 | 1080 | 850 | 1190 | 940 |
1x630 | 2.4 | 2.3 | 45 | 6220 | 2305 | ≤0.0283 | ≤0.0469 | 3.5 | 1250 | 1000 | 1350 | 1080 |
1x800 | 2.6 | 2.4 | 46 | 7870 | 2910 | ≤0.0221 | ≤0.0367 | 3.5 | 1400 | 1160 | 1520 | 1220 |
1x1000 | 2.8 | 2.6 | 51 | 9804 | 3604 | ≤0.0176 | ≤0.0291 | 3.5 | 1630 | 1330 | 1690 | 1380 |
Package and shipping:
1).Wrapped in rolls/coils/rings with plastic film for small diameter cables such as building wires.
2).Treated wooden/steel-wooden drums for big diameter cables.
3).Cables are normally supplied in lengths of 100 meters,500 meters and 1000 meters according to cable size.Other lengths could be supplied if agreements are reached by both side.
Packaging: In rolls/coils, wooden drums, steel drums or steel-wooden drums.
Shipping:
1. Sample will be mailed by DHL, UPS, FEDEX, TNT, EMS etc for your selection (Freight Charge normally will be on buyer’s account).
2. Large quantity will be shipped by sea.
Company introduction:
Established: 1996.
Factory area: 60,000 square meters, and 40,000 square meters for building area.
Fixed assets: USD 200 million.
No.of stuff : over 1,000.
Annual output: 100,000 tons.
Certificates: IEC, ISO 9001, ISO 14001, CCC, BV, JIS, UL, BS, OHSAS 18001, TUV, CE
CB and so on.
Workshops: rubber cable workshops, conductor workshop, XLPE cable workshop, electric cable workshop, special cable workshop, and workshops for telephone wire , TV lines and parvicostellae.
Zhengzhou Yuanda Cable Co. Ltd. located in the middle of China, and we can deliver qualified cable products in very short lead time.
Contact Us
- Zhengzhou Yuanda Cable Co., Ltd.
- Contact nameBecky Zhou
- Phone0086-371-55699718
- AddressNo. 2304, Floor 23, Bldg. 1, No. 157, Fuyuan Road, Jinshui Dist. Zhengzhou,Henan
- Application of high-voltage cables for locomotive equipment
- Manufacturing connection technology for automotive battery systems
- Vehicle High Voltage Cable Connection Test Results
- Automotive high voltage cable 35 square role
- Standard requirements for types of electric vehicle charging cables - Mode III
- Cables for automotive motor energy storage system applications
- Liquid-cooled charging systems applied to electric vehicle scenarios
- IEC 60502-2,GB/T 12706.2,GB/T 12706.3 IEC 60502-2 XLPE insulated,copper tape screened,unarmored power cable for voltages from 6kV up to 35kV
- IEC 60502-2,GB/T 12706.2,GB/T 12706.3 IEC 60502-2 XLPE insulated,copper tape screened,steel tape armored power cable for voltages from 6kV up to 35kV
- IEC 60502-2 IEC 60502-2 XLPE insulated,steel wire armored power cable for voltages from 6kV up to 35kV
- IEC 60502-1,GB/T 12706.1 0.6/1kV IE 60502-1 PVC insulated and sheathed power cable
- IEC 60502-1 0.6/1kV IEC 60502-1 XLPE insulated,PVC sheathed power cable
- EC 60502-1 0.6/1kV IEC 60502-1 XLPE insulated,PVC sheathed,steel tape armoured power cable
- IEC 60502-1 0.6/1kV IEC 60502-1 PVC insulated and sheathed,steel tape armoured power cable
- IEC 60502-1 0.6/1kV IEC 60502-1 XLPE insulated,PVC sheathed,steel wires armoured power cable
- IEC 60502-1 0.6/1kV IEC 60502-1 PVC insulated,PVC sheathed,steel wire armoured power cable
- AAC/XLPE,AAC/HDPE,AAAC/XLPE ,AAAC/HDPE Single-core aerial insulated cables for rated voltage of 10kV
- AAC/XLPE,AAAC/XLPE Aerial Single-core Insulated Cables with Rated Voltage 1kV or Lower
- Energy Storage Harness Technology
- Know the EV charging FAQs by understanding
- 95mm2 Vehicle Cable Applications for EVRP-125
- Introduction of material XLPE cable application characteristics
- Aerial Bundled Cable AAC/XLPE+AAC Duplex Service Drop Cables with Rated Voltage 600V to 1000V
- Introduction to cable production process
Popular Searches
Recommended Products
- BENTLY 1900/65A-00-04-01-00-00 Device monitor
- ABB XVC768101 3BHB007211R101 power interface Module
- ABB LD800HSE communication interface module
- ABB UAC389AE02 HIEE300888R0002 Excitation control module
- ABB UAC383AE01 HIEE300890R0001 Control board
- ABB PPC907BE101 3BHE024577R0101 frequency converter
- GE ESP10B Flow and pressure controller
- GE ESM10A Ethernet communication module
- ABB DSAO120A 3BSE018293R1 Excitation conditioning
- ABB KSD211B 3BHE022455R1101 Coupling device unit
- HONEYWELL 05701-A-0302 Single channel control card
- ABB XVC768115 3BHB007211R115 Remote IO devices
Find Similar Products By Category
- Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Becky Zhou
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-