Home > Electrical & Electronics > Relay & Contactor > Relay > QD100/101/068 Time Delay on Make ( 3 or 5 Minutes Fixed, .03-10 Minutes Adjustable)

QD100/101/068 Time Delay on Make ( 3 or 5 Minutes Fixed, .03-10 Minutes Adjustable)

QD100/101/068 Time Delay on Make ( 3 or 5 Minutes Fixed, .03-10 Minutes Adjustable) photo-1
US$ 1 - 2 MOQ: 100 Pieces
Key Specifications
Get Latest Price
Place of Origin:
Jiangsu, China
Brand Name:
HC
Model Number:
QD100/101/068
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai port
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Jiangsu, China
Brand Name HC
Model Number QD100/101/068
Theory Time Relay
Usage General Purpose
Size Miniature
Protect Feature Other
Contact Load Other

Specifications

* Time delay on make
* 3 minutes time delay
* 5 minutes time delay
* Knob adjustable time delay from .03-10 minutes

Time delay & time relay

Works with anticipator thermostat

* Time delay on make
* QD-100 3 minutes time delay
* QD-101 5 minutes time delay
* QD-068 Knob adjustable time delay from .03-10 minutes

 

 

QD100/101/068 time delay on make ( 3 or 5 minutes fixed, .03-10 minutes adjustable) 

   QD100/101/068 time delay on make ( 3 or 5 minutes fixed, .03-10 minutes adjustable)

 

QD100/101/068 time delay on make ( 3 or 5 minutes fixed, .03-10 minutes adjustable)

 Installation

1. Disconnect power.
2. Connect terminals in series with the starting device as shown in the system diagram below.
3. For 24 VAC circuits, apply control as packaged. For 120/240 VAC circuits, cut the jumper wire.
4. Select the desired time delay.
5. Reapply power, check operation.
6. Trickle current bypass resistor T1 to T3 < 1k ohm.
 
Specification
Input:
Line Voltage: 18-240 VAC/VDC
Line Frequency: 50/60 HZ
Output:
Output Ratings:
Maximum: 1.5 amps
Minimum: 40 mA
Inrush: 15 amps
Time Delay: .03-10 mins. adjustable
                     3 or 5 minute fixed
 
Mode of Operation
When power is applied to the input, the time delay begins. After the time delay is complete, the load energizes and remains energized as long as power is applied. The control is reset by removing power during or after the time delay period.
 
The QD-068 provides thermostat interruption protection, even in the presence of a trickle current.
 
Timing Diagram
 
QD100/101/068 time delay on make ( 3 or 5 minutes fixed, .03-10 minutes adjustable)
 
 
System Diagram
 
 
 
QD100/101/068 time delay on make ( 3 or 5 minutes fixed, .03-10 minutes adjustable)
 
 
 
For replaces
 
QD100/101/068 time delay on make ( 3 or 5 minutes fixed, .03-10 minutes adjustable)
 
 