Home > Products > Millivoltmeter > TVT-322D Digital Millivoltmeter
TVT-322D Digital Millivoltmeter
- 200 Piece / Pieces per Month
- shenzhen
- Credit Card
- Acrel Insulation fault locator Accurately locate the circuit where the insulation fault is located AIL150-4
- Acrel Using CAN bus technology, insulation faults of 8 circuits can be located Insulation fault locator AIL150-8
- Acrel current transmitter input AC 0-1/5A output 4-20mA power AC/DC 85-270V BD-AI
- Acrel Active power transmitter AC/DC85-270V 1 Channel analog output BD-3P
- Acrel BD-4E Multi-power digital transmitter 2 channels energy impulse output Rs485 modbus-RTU
- Acrel BD-4EA transmitter 2 channels energy impulse output Rs485 modbus-RTU Multi-power digital
Product Details
Place of Origin: | Guangdong, China | Brand Name: | LW | Model Number: | TVT-322D |
Display Type: | Digital Only | Measuring Range: | 100uV--400V | Accuracy Class: | 5Hz to 2MHz±4%±8digit 50Hz to 100 KHz: ±2.5%±10digit 50Hz to 100 |
Supply Voltage: | 220v 110v | Operating Temperature: | 10oC to 40oC | Dimensions: | 30*39*18cm |
Weight: | 3.5kg |
Product Description
Specifications
convenient and precisiondigital display
Features:
100uV--400V measuring voltage
10Hz--2MHzmeasuring frequency, max up to 5MHz
Auto and manual mode of measuring
Measuring ranges: mV/V/dBm
CH1 and CH2 selectable
Power supply: AC 220V (110V optional)
Specifications
Measuring Range:Voltage: 30uV to 300V dB:-79TO +59dB
DbM:-77TO 52dBm (0dBm=1mV, 600Ω)
Frequency Range: 5Hz to 2MHz
Voltage Error: 5Hz to 2MHz±4%±8digit 50Hz to 100 KHz: ±2.5%±10digit 50Hz to 100 kHz: 1.5%20digit Readout at 1 KHz as reference
dB Error: Voltage error±1 digit
dBm Error: Voltage error±1 digit
Input Impedance: 10MΩ±10%, 30pF
Resolution: 1uV
Noise: less than 15 digits (30mV TO 300V)
Ambient: 10oC to 40oC/85%RH
Power Supply: 220V/110V±10%, 50Hz/60HZ
Weight: 3kg
Contact Us
- Dongguan Longwei Electronic Technology Co., Ltd.
- Contact nameEdison Huang
- Phone86-0769-82033998
- Address2/F, No.45, Duozai Ling,Lin Village,Tangxia Town, Dongguan Guangdong Dongguan,Guangdong
- Acrel transmitter AC/DC85-270V 1 Channel analog output 4-20mA BD-4P Active powe
- Acrel remote terminal unit collect 8 switch signals and convert them to digital for data excharge RS485 ARTU-K8
- Acrel ARTU-K16 remote terminal unit collect 16 switch signals and convert them to digital for data excharge RS485
- Acrel ARTU-KJ8 remote terminal unit collect 8 switch signals 8 relay output signals and convert them to digital signals RS485
- Acrel ARTU-K32 for data excharge RS485 remote terminal unit collect 32 switch signals and convert them to digital
- Acrel Accurately locate the circuit AIL150-4 Insulation fault locator where the insulation fault is located
- Acrel Using CAN bus technology, insulation faults of 8 circuits can be located Insulation fault locator AIL150-8
- Acrel AKH-0.66/L L-200*50II current sensor Dedicated to residual current signal collection This product can output 5(2)mA twice
- Acrel AKH-0.66/L L-180II current transformers Dedicated to residual current signal collection This product can output 5(2)mA twice
- Acrel AKH-0.66/L L-150*130II Residual current sensor Can be used in conjunction with electrical fire monitoring devices, motor protection devices, etc.
- Acrel Residual current transformer is specially used for residual current signal collection AKH-0.66/L L-100*50II
- Acrel DC Solar string monitoring device AGF-M4T Applied to intelligent photovoltaic bus box Accuracy 0.5 class
- Acrel 12 channels energy meter solar string monitoring 0-1000V voltage measurement AGF-M12T DC0-20A
- Acrel 8 channel DC Multi-Circuits Monitoring Device AGF-M8T for PV Combiner Box 3.5KV Hall isolation
- Acrel Accuracy 0.5 class RS485/Modbus-RTU protocol AGF-M16T Intelligent photovoltaic confluence collection device
- Acrel Applied to intelligent photovoltaic bus box AGF-M20T DC0-20A Solar string monitoring device Accuracy 0.5 class
- Acrel 24 channels energy meter AGF-M24T DC0-20A solar string monitoring 0-1000V voltage measurement
- IEC60884-1 Figure 8 Plug Compression Tester
- IEC60065 Plug Torque Test Device for Testing the Direct Plug-In Equipment
- EN30-1-1 Standard Aluminum Sauce Pans for Testing on Gas Burners
- IEC60350-2 Low Carbon Steel Test Saucepan
- IEC60335-2-6 Aluminum Hob Element with Diameter 120mm
- GB21456 Low Carbon Steel Standard Pans with Lid
- GB30720 Standard Aluminum Pans for Domestic Gas Cooking Appliance
Popular Searches
Recommended Products
- ASTM D97 Automatic Pour Point of Petroleum Products Tester
- Automatic Atomic Absorption Spectrometer Elements Analyser
- Gas Chromatography Analyzer
- DIN 51805 Lubricating Grease Flow Pressure Tester
- Rail Wear Gauge Rail Profile Gauge for Rail Head Wear and Side Cut Measuring
- Track Gauge Railway Measuring Tools for Rail Maintenance
- ZnSe Window, Zinc Selenide Co2 Laser Engraving Machine Optical Lenses, ZnSe Window
- K9, Corning, Schott Material Optical Glass Lenses, Factory Customized Wedge Prism Optical Lens
- Fruit Hardness Tester FHT-05 for Blueberry
- Zinc Selenide used in co2 laser engraving machine, ZnSe window
- Factory Customized K9 Material Large Aperture Plano lens, Customized XJ Measuring Lens
- Customized Schott Microcrystal Dielectric High Reflection Large Cubic Mirror
Find Similar Products By Category
- Measurement & Analysis Instruments > Electrical Instruments > Other Electrical Instruments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Edison Huang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-