Home > Products > Marine Axial Fan > CZT110A Marine engine room ventilation fan
CZT110A Marine engine room ventilation fan
- 5000 Set / Sets per Month
- QINGDAO PORT/AIRPORT
- T/T L/C D/P D/A Credit Card PayPal
Product Details
Electric Current Type: | AC | Mounting: | Duct Fan | Blade Material: | Other, Aluminum |
Place of Origin: | Shandong, China | Brand Name: | YAOSEN | Model Number: | CZT series |
Voltage: | 220/230/380/400/415/420/440/480V etc. | Certification: | CCC, CSA, GS, ROHS, Other, CCC, CSA, GS, ROHS, CCS/ABS/RINA/RS/BV/DNV/LR/GL/VR etc | After-sales Service Provided: | Overseas service center available |
Product Description
CZT110A Marine engine room ventilation fan
CZT series Marine Ventilation Fan For Ship Use
1.Technical data:
Diameter:1100mm
Air flow:54000~60000M3/H
Pressure:740~680PA
Power:18.5KW
Frequency: 50/60HZ
Brand:Yaosen Marine
2.General
CZT series Marine ventilation fan for ship (simply the fans) are capable of blowing air, such as ocean air containing salt vapor and corrosive air containing a small quantity of oil vapor. They are suitable for cabin air ventilation and exchange on oceangoing vessels. They are also applicable in other places that suit.
The fan is designed and manufactured according to the standard of GB11864 marine or Navy Axial Flow Fans and The manufacture Rules of Sea-going Steel Ships.
3.Characteristics
CZT series Marine ventilation fan for ship Casing can be opened.
Reverse rotation possible.
Good anti-corrosiveness.
Strong performance in anti-swing, vibration-proof and impact resistant
4.Structure type
CZT series Marine ventilation fan for ship is manufactured with a built-in casing motor structure. The vane wheel is directly mounted on the motor shaft.
The vane wheel is made of anti-corrosive case aluminum alloy while the casing is made of welded common steel.
As desired, the casing can either be made into an integral one or an open type along the axial direction. In the later case, the vane wheel and the casing so as to bring convenience for on-the-spot repair and the replacement of its spare parts.
Viewed from the motor side, the vane wheel rotates clockwise while in service the ventilator is allowed to rotate reversely.
The ventilator can be matched with marine DC motor of 380V, 50HZ or 440V,60HZ.
Medium temperature: -25°C ~ +50°C
Max relative humidity: 95%
Periodical swing:±22.5°
Continued transversal incline:±15°
Continued longitudinal incline:±10°
Vibration: existent
Impact: existent
6.CZT Marine Axial Fan Drawings
We could Design and Produce the Marine fan,Industrial Fan,and Other Ventilation Equipment according to your detailed requirement !
7.Introduction for ordering
7.1 Please introduce the model, flow prate, pressure, speed and structure of fan,50HZ or 60HZ.
7.2 If the fan on the deck, according to relevant provisions of the chassis thickness.
7.3 Please offer insulation class and protection class for fan motor (if not, the insulation class is F, protection class is IP56).
7.4 Our factory can offer the fans of special specification and usage according to the user's demands.
7.5 We are responsible for the repair, exchange and return of the products Within 18 months.
8.Use and maintenance
8.1 Before installing the fans, should check whether each part is intact, whether the components are complete, whether the impeller and casing rotating direct are concordant.
8.2 When installing the duct of the inlet and outlet, should make the duct and fans be spontaneous identical, not join them forcing, not bring the weight of duct on the fans.
8.3After installed the fans, check whether there is friction of collide between the impeller and the fixed parts by rotating the impeller. If collision, friction, loud noise or strong vibration happened, the fan should be restart after checking. Avoid the fan being bumped and other substance or liquid entered the fans. Please clean the dust on blade of impeller in time, so as not to break the balance and strengthen the noise.
8.4 The fans should be started-up while the inlet is opening,
8.5After the fans wiring, the terminal box should be sealed, avoid the air or water in it.
8.6As the fans operating, the motor electric current should be control strictly, not exceed the rated electric current. Avoid the motor burning,
8.7The fans maintain must be done on stop working time. When burning, after check, should whether the every part of fans is normal.
8.8As some fault occurred in fans operating, should find out the reason in time and think a way of resolution.
9.Main products:
CBL series marine explosion-proof centrifugal fan
CBZ series marine explosion-proof axial flow fans
CGDL Series marine or navy high efficiency low noise centrifugal fans
CLZ series Marine high pressure axial-flow fans
CQ series Marine High pressure centrifugal ventilator
CSL series centrifugal water power fans for marine use
CSZ series water driven gas free axial flow fans for marine or navy use
CWL(CXL) series marine small-size Centrifugal fans
CWZ series marine or navy small-sized axial fans
CZF series marine axial-flow fans
JCL(CLQ)series marine centrifugal ventilator fan
CZ Series marine axial-flow ventilator fan
CDZ series Marine low noise axial fans for marine or navy use
CBGD series marine explosion-proof (non-sparking) centrifugal fan
CZT Series Marine axial flow fan for ship use
Contact Us
- Qingdao Yaosen Marine Industrial Equipment Co., Ltd.
- Contact nameSteven Jones
- Phone86-532-88078520
- AddressNO.8-18 Xitai Industrial Park,Qingdao,China Qingdao,Shandong
- CWZ-224D marine small-sized axial draft fan
- CWZ-200G marine small-sized axial fan
- CWZ-200D marinesmall-sized axial flow fan
- CLZ14-J marine high pressure axial draft fan
- CLZ13-J marine vertical axial exhaust fan
- CLZ12-J marine high pressure axial flow fan
- CLZ11-J marine vertical axial flow fan
- CLZ10-J vertical marine axial draft fan
- CLZ9-J high pressure marine axial supply fan
- CLZ8-J vertical marine axial supply blower
- CLZ6-J high pressure marine duct fan
- CLZ5-J marine duct fan for machine room
Popular Searches
Recommended Products
- 2NB3/1.5-2.2 mining mud pump is a vertical, double cylinder, single acting plunger pump
- 5 ton/10 ton/20 ton/30ton QDY Double girder ladle steel making foundry bridge crane
- YXS-05 8 Rows Seeding Machine (Grass Seed) for Dryland Sowing Fertilizing
- YXS-07 8/12 Rows Rice Direct Seeding Machine for Paddy Land Planting
- 12 Rows 600L Pneumatic Seeder for Seeds Fertilizer Sowing and Fertilizing
- 8 Rows 350L Pneumatic Seeder for Rice Wheat Soybean Seeding and Fertilizing
- 12 Rows 100L Pneumatic Seeder for Rice Wheat Sowing and Fertilizing
- 12 Rows 300L Pneumatic Seeder for Rice Wheat Sowing and Fertilizing
- 8 Rows 150L Pneumatic Seeder for Rice Wheat Soybean Sowing and Fertilizing
- Metal mesh weaving machine weft accumulator
- Metal wire mesh weaving machine Three roller take up without stop the machine
- High speed soft rapier metal wire mesh weaving machine metal wire cloth loom
Find Similar Products By Category
- Machinery > General Industrial Equipment > Ventilation Fans > Axial Flow Fans
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Steven Jones
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-