Home > Consumer Electronics > Water Heater & Components > Heat Pump Water Heater > EVI DC Inverter Heat Pump Air to Water Water Heater With EN14511 for Low Temperature Area

EVI DC Inverter Heat Pump Air to Water Water Heater With EN14511 for Low Temperature Area

EVI DC Inverter Heat Pump Air to Water Water Heater With EN14511 for Low Temperature Area photo-1
US$ 2,700 - 6,400 MOQ: 1 Set
Key Specifications
Get Latest Price
Type:
Air Source Heat Pump
Installation:
Freestanding
Storage / Tankless:
Storage
Payment & Shipping
Payment Methods:
Port of Shipment:
Shunde or Guangzhou
Delivery Detail:
Delivery time depends on order quantity.
Type Air Source Heat Pump
Installation Freestanding
Storage / Tankless Storage
Housing Material Stainless Steel
Use Other, cooling ,heating and domestic hot water
Certification CE, Other, CE, RoHS, CCC,ISO9001
Place of Origin Guangdong, China
Brand Name Macon
Model Number MACHRW40W/(BE01)

 EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

 

New design EVI DC Inverter low temp. heat pump water heater/chiller 

 

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

  

 

 

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

 

 

 

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

 

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

 

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

INDOOR UNIT MACHRW 040W/(BE01) 050W/(BE01) 040W/S(BE01) 050W/S(BE01) 060W/S(BE01)
OUTDOOR UNIT MAFP 040A 050A 040A 050A 060A
Rated Cooling Capacity kW 10.0 12.5 10.0 12.5 15.0
BTU/h 34200 42700 34200 42700 51200
Rated Input Power(Cooling) kW 3.13 3.91 3.13 3.91 4.69
Rated Input Current(Cooling) A 14.2 17.8 8.2 10.3 7.1
Rated Heating Capacity(A7/W35) kW 12.0 15.0 12.0 15.0 18.0
BTU/h 41000 51200 41000 51200 61500
COP(A7/W35)   4.35 4.30 4.25 4.25 4.20
Rated Input Power(Heating)(A7/W35) kW 2.76 3.49 2.82 3.53 4.29
Rated Input Current(Heating)(A7/W35) A 12.5 15.9 7.4 9.3 6.5
Rated Heating Capacity(A2/W35) kW 12.0 15.0 12.0 15.0 18.0
BTU/h 41000 51200 41000 51200 61500
COP(A2/W35)   3.45 3.40 3.45 3.40 3.35
Rated Input Power(Heating)(A2/W35) kW 3.48 4.41 3.48 4.41 5.37
Rated Input Current(Heating)(A2/W35) A 15.8 20.1 9.1 11.6 8.2
Rated Heating Capacity(A-7/W35) kW 12.0 15.0 12.0 15.0 18.0
BTU/h 41000 51200 41000 51200 61500
COP(A-7/W35)   2.80 2.75 2.80 2.70 2.65
Rated Input Power(Heating)(A-7/W35) kW 4.29 5.45 4.29 5.56 6.79
Rated Input Current(Heating)(A-7/W35) A 19.5 24.8 11.2 14.6 10.3
Rated Heating Capacity(A7/W45) kW 12.0 15.0 12.0 15.0 18.0
BTU/h 41000 51200 41000 51200 61500
COP(A7/W45)   3.60 3.60 3.60 3.60 3.60
Rated Input Power(Heating)(A7/W45) kW 3.33 4.17 3.33 4.17 5.00
Rated Input Current(Heating)(A7/W45) A 15.2 18.9 8.7 10.9 7.6
Rated Heating Capacity(A-7/W45) kW 12.0 15.0 12.0 15.0 18.0
BTU/h 41000 51200 41000 51200 61500
COP(A-7/W45)   2.50 2.40 2.50 2.50 2.40
Rated Input Power(Heating)(A-7/W45) kW 4.80 6.25 4.80 6.00 7.50
Rated Input Current(Heating)(A-7/W45) A 21.8 28.4 12.6 15.7 11.4
Power Supply V/PH/Hz 200V-50Hz/200~220V-60Hz 380~415V-50Hz
Compressor   EVI DC Inverter EVI DC Inverter EVI DC Inverter EVI DC Inverter EVI DC Inverter
Compressor Qty   1 1 1 1 1
indoor unit Noise dB(A) 38 38 38 38 38
outdoor unit Noise dB(A) 52 52 52 52 52
Water outlet/water inlet inch 1" 1" 1" 1" 1"
Water Flow Volume m3/h 2.06 2.58 2.06 2.58 3.10
Refrigerant Gas Type          
Indoor unit Net Dimensions(L/M/H) mm 600/600/760 600/600/760 600/600/760 600/600/760 600/600/760
Indoor unit Shipping Dimensions(L/M/H) mm 650/730/810 650/730/810 650/730/810 650/730/810 650/730/810
outdoor unit Net Dimensions(L/M/H) mm 880/360/800 930/390/1270 880/360/800 930/390/1270 930/390/1270
outdoor unit Shipping Dimensions(L/M/H) mm 1020/450/830 1080/480/1310 1020/450/830 1080/480/1310 1080/480/1310
Indoor unit Net Weight kg 93 95 93 95 115
Indoor unit Shipping Weight kg 108 110 108 110 130
Outdoor unit Net Weight kg 50 70 50 70 70
Outdoor unit Shipping Weight kg 55 75 55 75 75
 Note:(1)Cooling:Outdoor air temp:35℃/24℃,Outlet water temp:7℃,Inlet water temp:12 ℃;
      (2)Using in ambient temperature:-25℃~43℃.

 EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

EVI DC inverter heat pump fertures:

1.Compressor

Super heating EVI DC inverter scroll compressor.

2.High speed heating start up

The performance of heating start up is improved.

3.High heating capacity

Industry-first injection circuit is equipped,which enable to keep the equal capacity with the even when outside temperature is -15 °C.but, The traditional heat pump can only reach 60% of the rated heating capacity output.

4.Evaporator

Evaporator is larger 30% than usual size to keep its high efficiency.

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

 

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

Our Service
1) MACON can supply OEM service for customers.
2) Produce heat pump according to customer's special demands.
3) Supply spare parts according to order quantity.
4) Warranty: 1% free spare parts
Certificate
Obtain certificates CE, ROHS, SAA, Water mark, Standard mark, C- tick, ETL, CCC, and pass ISO9001:2000

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

 

EVI DC Inverter heat pump air to water water heater with EN14511 for low temperature area

 

FAQ Frequently Asked Questions

1. Can I use our own brand logo on the products?
Yes. We provide OEM/ODM service to our customers.
2. Can you do special product for us?
Yes. We have professional engineers having rich experience in heat pump design and manufacturing. Just tell us your ideas or provide the drawing, we can help to carry out your ideas into real products.
3. What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.
4. What is your terms of delivery?
We accept EXW, FOB, CIF, etc. You can choose the one which is the most convenient or cost effective for you.
5. What is your payment terms?
-For sample order: T/T 100% 
-For container order: T/T 30% deposit, T/T 70% before shipment or L/C
6. What about warranty?
We usually provide 1% free spare parts according to your order quantity.

 

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2007
Factory Size
10,000-30,000 square meters
Total Employees
101 - 200 People

Recommended Categories

Explore top categories and find suppliers for your specific needs