Generating set spectrum chart of WP4/WP6 series marine emergency diesel generator set (Marathon generator)
| engine type | Rated power kW | Diesel engine model | Rated power of diesel enginekW | intake mode | Dimension mm | Weight kg | ||
| CCFJ30Y -WJ | 30 | TD226B -4CD1 | 60 | turbocharged | 1871 | 600 | 1546 | 925 |
| CCFJ40Y -WJ | 40 | TD226B -4CD1 | 60 | turbocharged | 1818 | 600 | 1546 | 915 |
| CCFJ50Y -WJ | 50 | TD226B -4CD1 | 60 | turbocharged | 1818 | 600 | 1546 | 915 |
| CCFJ64Y -WJ | 64 | WP90CD -15 | 90 | turbocharged | 2219 | 778 | 1575 | 1450 |
| CCFJ75Y -WJ | 75 | WP120CD -15 | 90 | turbocharged | 2219 | 778 | 1575 | 1450 |
| CCFJ90Y -WJ | 90 | WP120CD -15 | 120 | turbocharged and intercooled | 2480 | 798 | 1627 | 1550 |
| CCFJ100Y -WJ | 100 | WP120CD -15 | 120 | turbocharged and intercooled | 2480 | 798 | 1627 | 1550 |
| CCFJ120Y -WJ | 120 | WP180CD -15 | 132 | turbocharged and intercooled | 2480 | 798 | 1627 | 1600 |
Generating set spectrum chart of WP4/WP6 series marine emergency diesel generator set (Orchid electric generator)
| engine type | Rated power kW | Diesel engine model | Rated power of diesel enginekW | intake mode | Dimension mm | Weight kg | ||
| CCFJ30 Y-WF | 30 | TD226B -4CD1 | 60 | turbocharged | 1946 | 600 | 1546 | 975 |
| CCFJ40 Y-WF | 40 | TD226B -4CD1 | 60 | turbocharged | 1946 | 600 | 1546 | 975 |
| CCFJ50 Y-WF | 50 | TD226B -4CD1 | 60 | turbocharged | 1946 | 600 | 1546 | 975 |
| CCFJ64 Y-WF | 64 | WP90CD -15 | 90 | turbocharged | 2359 | 778 | 1575 | 1500 |
| CCFJ75Y-WF | 75 | WP120CD-15 | 90 | turbocharged | 2359 | 778 | 1575 | 1500 |
| CCFJ90Y-WF | 90 | WP120CD-15 | 120 | turbocharged and intercooled | 2480 | 798 | 1627 | 1600 |
| CCFJ100Y-WF | 100 | WP120CD-15 | 120 | turbocharged and intercooled | 2480 | 798 | 1627 | 1600 |
| CCFJ120Y-WF | 120 | WP180CD-15 | 132 | turbocharged and intercooled | 2567 | 798 | 1627 | 1680 |
Generating set spectrum chart of WP4/WP6 series marine emergency diesel generator set (Stanford generator)
| engine type | Rated power kW | Diesel engine model | Rated power of diesel enginekW | intake mode | Dimension mm | Weight kg | ||
| CCFJ30Y -WV | 30 | TD226B -4CD1 | 60 | turbocharged | 1947 | 600 | 1546 | 961 |
| CCFJ40Y -WV | 40 | TD226B -4CD1 | 60 | turbocharged | 1947 | 600 | 1546 | 920 |
| CCFJ50Y -WV | 50 | TD226B -4CD1 | 60 | turbocharged | 1947 | 600 | 1546 | 920 |
| CCFJ64Y -WV | 64 | WP90CD -15 | 90 | turbocharged | 2354 | 798 | 1575 | 1500 |
| CCFJ75Y -WV | 75 | WP120CD -15 | 90 | turbocharged | 2354 | 798 | 1575 | 1500 |
| CCFJ90Y -WV | 90 | WP120CD -15 | 120 | turbocharged and intercooled | 2580 | 798 | 1627 | 1580 |
| CCFJ100Y -WV | 100 | WP120CD -15 | 120 | turbocharged and intercooled | 2580 | 798 | 1627 | 1600 |
| CCFJ120Y -WV | 120 | WP180CD -15 | 132 | turbocharged and intercooled | 2580 | 798 | 1627 | 1620 |
Generating set spectrum chart of WP4/WP6 series marine emergency diesel generator set (Siemens generator)
| engine type | Rated power kW | Diesel engine model | Rated power of diesel enginekW | intake mode | Dimension mm | Weight kg | ||
| CCFJ30Y -WZ | 30 | TD226B -4CD1 | 40 | turbocharged | 2250 | 600 | 1546 | 965 |
| CCFJ40Y -WZ | 40 | TD226B -4CD1 | 60 | turbocharged | 2250 | 600 | 1546 | 1000 |
| CCFJ50Y -WZ | 50 | TD226B -4CD1 | 60 | turbocharged | 2416 | 778 | 1575 | 1520 |
| CCFJ64Y -WZ | 64 | WP90CD -15 | 90 | turbocharged | 2416 | 778 | 1575 | 1560 |
| CCFJ75Y -WZ | 75 | WP120CD -15 | 90 | turbocharged | 2581 | 798 | 1627 | 1700 |
| CCFJ90Y -WZ | 90 | WP120CD -15 | 120 | turbocharged and intercooled | 2581 | 798 | 1627 | 1750 |
| CCFJ100Y -WZ | 100 | WP120CD -15 | 120 | turbocharged and intercooled | 2581 | 798 | 1627 | 1820 |
| CCFJ120Y -WZ | 120 | WP180CD -15 | 132 | turbocharged and intercooled | 2050 | 600 | 1546 | 930 |
Dimensions
Installation dimension of WP4/WP6 series marine emergency diesel generator set (Marathon generator)
| Model | A | A1 | B | L | L1 | W | H | R | D |
| CCFJ30Y-WJ | 700 | 247 | 550 | 1871 | 1832 | 600 | 1546 | 6 | 19 |
| CCFJ40Y-WJ | 700 | 300 | 550 | 1818 | 1818 | 600 | 1546 | 6 | 19 |
| CCFJ50Y-WJ | 700 | 300 | 550 | 1818 | 1818 | 600 | 1546 | 6 | 19 |
| CCFJ64Y-WJ | 600 | 240 | 722 | 2219 | 2219 | 778 | 1575 | 8 | 19 |
| CCFJ75Y-WJ | 600 | 240 | 722 | 2219 | 2219 | 778 | 1575 | 8 | 19 |
| CCFJ90Y-WJ | 600 | 300 | 742 | 2480 | 2480 | 798 | 1627 | 8 | 19 |
| CCFJ100Y-WJ | 600 | 300 | 742 | 2480 | 2480 | 798 | 1627 | 8 | 19 |
| CCFJ120Y-WJ | 600 | 300 | 742 | 2480 | 2194 | 798 | 1627 | 8 | 19 |
Installation dimension of WP4/WP6 series marine emergency diesel generator set (Orchid electric generator)
| Model | A | A1 | B | L | L1 | W | H | R | D |
| CCFJ30Y-WF | 700 | 246 | 550 | 1946 | 1946 | 600 | 1546 | 6 | 19 |
| CCFJ40Y-WF | 700 | 246 | 550 | 1946 | 1946 | 600 | 1546 | 6 | 19 |
| CCFJ50Y-WF | 700 | 246 | 550 | 1946 | 1946 | 600 | 1546 | 6 | 19 |
| CCFJ64Y-WF | 600 | 240 | 722 | 2359 | 2359 | 778 | 1575 | 8 | 19 |
| CCFJ75Y-WF | 600 | 240 | 722 | 2359 | 2359 | 778 | 1575 | 8 | 19 |
| CCFJ90Y-WF | 600 | 300 | 742 | 2480 | 2480 | 798 | 1627 | 8 | 19 |
| CCFJ100Y-WF | 600 | 300 | 742 | 2480 | 2480 | 798 | 1627 | 8 | 19 |
| CCFJ120Y-WF | 600 | 300 | 742 | 2567 | 2530 | 798 | 1627 | 8 | 19 |
Installation dimension of WP4/WP6 series marine emergency diesel generator set (Stanford generator)
| Model | A | A1 | B | L | L1 | W | H | R | D |
| CCFJ30Y-WV | 700 | 247 | 550 | 1947 | 1947 | 600 | 1546 | 6 | 19 |
| CCFJ40Y-WV | 700 | 247 | 550 | 1947 | 1947 | 600 | 1546 | 6 | 19 |
| CCFJ50Y-WV | 700 | 247 | 550 | 1947 | 1947 | 600 | 1546 | 6 | 19 |
| CCFJ64Y-WV | 600 | 280 | 742 | 2354 | 2354 | 798 | 1575 | 8 | 19 |
| CCFJ75Y-WV | 600 | 280 | 742 | 2354 | 2354 | 798 | 1575 | 8 | 19 |
| CCFJ90Y-WV | 600 | 300 | 742 | 2580 | 2580 | 798 | 1627 | 8 | 19 |
| CCFJ100Y-WV | 600 | 300 | 742 | 2580 | 2580 | 798 | 1627 | 8 | 19 |
| CCFJ120Y-WV | 600 | 300 | 742 | 2580 | 2580 | 798 | 1627 | 8 | 19 |
Installation dimension of WP4/WP6 series marine emergency diesel generator set (Siemens generator)
| Model | A | A1 | B | L | L1 | W | H | R | D |
| CCFJ30Y-WZ | 700 | 300 | 550 | 2050 | 2050 | 600 | 1546 | 6 | 19 |
| CCFJ40Y-WZ | 700 | 300 | 550 | 2250 | 2250 | 600 | 1546 | 6 | 19 |
| CCFJ50Y-WZ | 700 | 300 | 550 | 2250 | 2250 | 600 | 1546 | 6 | 19 |
| CCFJ64Y-WZ | 600 | 280 | 722 | 2416 | 2359 | 778 | 1575 | 8 | 19 |
| CCFJ75Y-WZ | 600 | 280 | 722 | 2416 | 2359 | 778 | 1575 | 8 | 19 |
| CCFJ90Y-WZ | 600 | 100 | 742 | 2581 | 2581 | 798 | 1627 | 10 | 19 |
| CCFJ100Y-WZ | 600 | 100 | 742 | 2581 | 2581 | 798 | 1627 | 10 | 19 |
| CCFJ120Y-WZ | 600 | 100 | 742 | 2581 | 2581 | 798 | 1627 | 10 | 19 |
Note: 226B/WP4/WP6 marine emergency diesel generator set silencer diameter of outlet: 30--50kWφ68, 64--75kWφ72, 90-120kWφ96. The table size is subject to 1500rpm/400V generator sets.
CONTACT:
Name: Elaine Zheng
Tel: 86-592-3686566
Mobile: +8618359108305
WhatsApp: +8618359108305
Skype: Homealine93
Wechat: Homelaine
Email: sales1@sitaiqi. com
Send Inquiry to This Supplier
You May Also Like
-
20KW 25KVA WP2.3D25E200 WEICHAI Open Type Generator SetUS$ 2300 - 2500MOQ: 1 Set
-
Hot Sell Diesel Welder Generator S7500D(E)W 6 Months,6months 3-5 Days HUBEI JULY 1pc Original / Neutral / Customized.NegotiableMOQ: 1
-
Diesel Twin Cylinder Generator SetUS$ 2300 - 4100MOQ: 1 Piece
-
Car Generator Alternator 31100-RFE-013 For 2005-Hon DaO DYS SEY RB1 2.4LNegotiableMOQ: 1
-
60kv VLF ac Hipot Tester Electric 30kv Ultra Low Frequency High Voltage Vlf GeneratorUS$ 2,500 - 9,000MOQ: 1 Piece
-
7.5; 6.5; 5.5 Horse Power Engine With Clutch 1/2C Forced Air-cooling Recoil Strart Single Cylinder Essence MoteurUS$ 9 - 15MOQ: 50 Sets
-
Turbocharged Electric Start Water Cooled Marine Diesel Generator SetUS$ 2,000 - 8,000MOQ: 1 Set
-
Aftermarket Kubota Alternator 15531-64017US$ 5 - 30MOQ: 1 Piece
-
Vlais KDE3500E 3kw Diesel Generator,Open Frame Diesel Generator With Electric StartNegotiableMOQ: 1 Piece
-
Diesel Engine Generator - QC490DNegotiableMOQ: 1 Set