High Voltage Fuse for Transformer Protection
Applications
H.V current-limiting fuses type S is mainly used in AC50Hz,rated voltage 3.6~40.5KV,rated current up to 200A circuit for protection transformers and power equipments from overload and short-circuit.It can also be used with load switch,vacuum contact. It conforms to IEC282-1,GB15166.2 and DIN standard.
Design Features
S type H.V HRC current-limiting fuses is insert installation.The striker parallers to the fuse element made from pure silver. They are sealed in the fuse tube filled with chemically treated high-purity quartz sand. The fuse tube is made from heat resistance,high duty ceramic or expoxy glass.
When fault circuit happens, the fuse link melts, the high-resistant metal wire paralleling to fuse links melts immediately at the appearance of the arc, and the striker jumps out to push the chained equipment contact, signaling the melting automatically cuttig the circuit.
The striker has spring type striker jumps out to push ethe chained equipment contact, signaling the melting automatically cutting the circuit. The striker has spring type striker use high pressure caused by the lighting powder to push the striker.
S type H.V.HRC current-limiting fuses has many merits as high current-limiting ablilty, high breaking capacity, quick and punctual in action, reliable in performance.
DIN HRC "S" type high voltage fuse for transformer protection:
1. According to bussmann DIN "S" type high performance back-up fuse
2. Comply with IEC282-1, DIN, BS
3. This fuse is intended to protect distribution networks and transformer, for indoor as well as outdoor use.
4. Any other specifications can be designed specially.
| model | Rated voltage (KV) | rated current of the fuse links (A) | Rated breaking current (KA) | dimensions (mm) | ||
| Foreign | Department | |||||
| SDO.J | XRNT1 | 3.6 see figure 1 | 6.3/10/16/20/25/31.5/40 | 50 | 51 | 192 |
| SDL.J | XRNT1 | 7.2 see figure 1 | 6.3/10/16/20/25/31.5/40/50/63 | 50 | 51 | 292 |
| SFL.J | XRNT1 | 7.2 see figure 1 | 80/100/125/160 | 50 | 76 | 292 |
| SDL.J | XRNT1 | 12 see figure 1 | 6.3/10/16/20/25/31.5/40 | 50 | 51 | 292 |
| SFL.J | XRNT1 | 12 see figure 1 | 50/63/71/80/100 | 50 | 76 | 292 |
| SKL.J | XRNT1 | 12 see figure 1 | 125 | 50 | 76 | 292 |
| SXL.J | XRNT1 | 12 see figure 1 | 160/200 | 50 | 88 | 292 |
| SDM.J | XRNT1 | 24 see figure 2 | 6.3/10/16/20/25/31.5/40 | 40 | 51 | 442 |
| SFM.J | XRNT1 | 24 see figure 1 | 50/63/71/80/100 | 40 | 76 | 442 |
| SKM.J | XRNT1 | 24 see figure 1 | 125 | 40 | 76 | 442 |
| SXM.J | XRNT1 | 24 see figure 1 | 160 | 40 | 88 | 442 |
| SDQ.J | XRNT1 | 40.5 see figure 3 | 3.15/6.3/10/16/20/25 | 31.5 | 51 | 537 |
| SFQ.J | XRNT1 | 40.5 see figure 3 | 31.5/40 | 31.5 | 76 | 537 |
| SXQ.J | XRNT1 | 40.5 see figure 3 | 63 | 31.5 | 88 | 537 |
Note:under stipulated condition,min.breaking current of fuses could be as high as 2.5-3times than ratred current
Transformer capacity (KVA) | Transformer primary voltage | |||
| 7.2 (KV) | 10(KV) | 20(KV) | 30(KV) | |
Fuse model/ rated current (A) | Fuse model/ rated current (A) | Fuse model/ rated current (A) | Fuse model/ rated current (A) | |
| 50 | SDL.J-7.2KV/8A | SDL.J-12KV/6.3A | SDM.J-24KV/3.15A | SDQ.J-40.5KV/3.15A |
| 100 | SDL.J-7.2KV/16A | SDL.J-12KV/10A | SDM.J-24KV/6.3A | SDQ.J-40.5KV/6.3A |
| 125 | SDL.J-7.2KV/20A | SDL.J-12KV/12A | SDM.J-24KV/6.3A | SDQ.J-40.5KV/6.3A |
| 160 | SDL.J-7.2KV/25A | SDL.J-12KV/16A | SDM.J-24KV/8A | SDQ.J-40.5KV/6.3A |
| 200 | SDL.J-7.2KV/31.5A | SDL.J-12KV/20A | SDM.J-24KV/10A | SDQ.J-40.5KV/8A |
| 250 | SDL.J-7.2KV/40A | SDL.J-12KV/25A | SDM.J-24KV/12A | SDQ.J-40.5KV/10A |
| 300/315 | SDL.J-7.2KV/50A | SDL.J-12KV/31.5A | SDM.J-24KV/16A | SDQ.J-40.5KV/10A |
| 400 | SDL.J-7.2KV/63A | SDL.J-12KV/40A | SDM.J-24KV/20A | SDQ.J-40.5KV/16A |
| 500 | SDL.J-7.2KV/80A | SDL.J-12KV/50A | SDM.J-24KV/25A | SDQ.J-40.5KV/16A |
| 630 | SDL.J-7.2KV/100A | SDL.J-12KV/63A | SDM.J-24KV/31.5A | SDQ.J-40.5KV/20A |
| 750/800 | SDL.J-7.2KV/125A | SDL.J-12KV/80A | SDM.J-24KV/40A | SDQ.J-40.5KV/25A |
| 1000 | SDL.J-7.2KV/160A | SDL.J-12KV/100A | SDM.J-24KV/50A | SDQ.J-40.5KV/31.5A |
| 1250 | SDL.J-12KV/125A | SDM.J-24KV/63A | SDQ.J-40.5KV/40A | |
| 1600 | SDL.J-12KV/160A | SDM.J-24KV/80A | SDQ.J-40.5KV/50A | |
| 2000 | SDL.J-12KV/200A | SDM.J-24KV/100A | SDQ.J-40.5KV/63A | |
Welcome to contact us to more details. Some details could be ordered according to the requirement of customers.
Send Inquiry to This Supplier
You May Also Like
-
Fuse Clip for High Voltage Current Limiting FuseUS$ 4.75 - 6MOQ: 100 Pairs
-
HV HRC Fuses for Transformer ProtectionUS$ 7.8 - 28MOQ: 30 Pieces
-
24kv High Voltage Current Limiting Fuse for Transformer Protection / High Rupturing Capacity Fuse/porcelain Body Fuse/XRNP TypeUS$ 10.5 - 27.5MOQ: 30 Pieces
-
High-voltage Current-limiting Fuse is Used for Transformer Protection( XRNT-hrc Fuse) /3.6KV/7.2KV/12KV/24KV/40.5KVUS$ 60 - 180MOQ: 3 Pieces
-
High Voltage HRC Fuses for Transformer Protection Length=605mmUS$ 60 - 180MOQ: 3 Pieces
-
7.2KV High Voltage HRC Fuses for Transformer Protection(XRNT)/porcelain High Voltage FuseUS$ 60 - 180MOQ: 3 Pieces
-
High-voltage Fuse Types XRNT for Transformer Protection With 24KVUS$ 60 - 180MOQ: 3 Pieces
-
High Voltage HRC Fuses for Transformer Protection / 24kv Voltage/porcelain Body/UL,CE Cerficate)US$ 11.5 - 27.5MOQ: 3 Pieces
-
12kV H.V Fuses for Transformer ProtectionUS$ 7.2 - 8MOQ: 30 Pieces
-
Ceramic Tube Fuse for Transformer Protection 12kVUS$ 10.7 - 12.5MOQ: 30 Pieces