Home > Instruments & Meters > Meter for Liquid & Gas > Flow Meter > Cheap Industrial Water Electromagnetic Flowmeter

Cheap Industrial Water Electromagnetic Flowmeter

Cheap Industrial Water Electromagnetic Flowmeter photo-1
Cheap Industrial Water Electromagnetic Flowmeter photo-2
Cheap Industrial Water Electromagnetic Flowmeter photo-3
Cheap Industrial Water Electromagnetic Flowmeter photo-4
US$ 399 - 3,999 MOQ: 1 Set
Key Specifications
Get Latest Price
Place of Origin:
Henan, China
Brand Name:
kaide Water Electromagnetic Flowmeter
Model Number:
KDLD Water Electromagnetic Flowmeter
Payment & Shipping
Payment Methods:
Port of Shipment:
Qingdao Shanghai
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Henan, China
Brand Name kaide Water Electromagnetic Flowmeter
Model Number KDLD Water Electromagnetic Flowmeter

Specifications

Water Electromagnetic Flowmeter,
1.Medium:water,liquid,slurry,etc.
2.Diameter size:DN10~3000mm
3.Pulse,4~20mA output,RS485

 
Product Description

Product Name: Cheap Industrial Water Electromagnetic Flowmeter

 

Introduction-- Water Electromagnetic Flowmeter

 

KDLD water electromagnetic flowmeter measuring instrument / tool is manufactured with the modern technology of electromagnetic flow, the measuring principle of which is based on the electromagnetic induction law of Farady. It is mainly used to measure the volume flow of conducting liquid and slurry in closed pipeline, applicable to industries like chemical, power supply, metallurgical mine, oil, water supply and drainage, paper making, pharmaceutical, food, etc..

 

Specifications-- Water Electromagnetic Flowmeter

Item

Compact type

Remote type

 

Flange connection

Inserted type

Threaded connection

Flange connection

Inserted type

Threaded connection

Caliber(mm)

15~3000

125~3000

10~25

15~3000

125~3000

10~25

Pressure(MPa)

0.6,1.0,1.6,4.0

Accuracy

±0.5%, ±0.3%(±0.2% available for special order)

Applicable medium

Conductive liquid and slurry

Medium Temperature

≤150°C

Medium Conductivity

≥5μS/cm

Medium Velocity

≤15 m/s

Ambient

Temperature:-25°C~+60°C, Humidity: 5%~90%

Liner Material

DN10mm~32mm: Polytetrafluoroethylene(F4), Polyurethane;
DN40mm~1000mm: F4, Polyurethane, Polychloropree rubber;
DN1000mm~3000mm: Polychloropree rubber;
Others: Polyvinyl fluoride, Fluorinated ethylene-propylene(FEP), etc.

Electrode Material

Mo-containing stainless steel, Hastelloy B, Hastelloy C, Titanium alloy, Tantalum alloy, Platinum-iridium alloy, Stainless steel-coated tungsten carbide

Electrode Type

Fixed type(DN150~DN2600); Blade type(DN300~DN1600)

Flange Material

SS, CS

Communication

RS485, RS232, HART, Modbus, Profibus-DP

Signal Output

Analog 4-20mA, pulse, isolated, load resistor≤750Ω

Power Supply

AC 85-265V, 45-63Hz, power≤20W;
DC 11-40V; lithium battery(3.6V)

AC 85-265V, 45-63Hz, power≤20W;
DC 11-40V

Display

LCD display with back light.

Intelligent flow totalizer display.

Protection Grade

IP65

IP65, IP67, IP68

Explosion-
proof Grade

ExdmⅡCT4, mdⅡBT4

non

 

 
Company Information

 Company Information--Water Electromagnetic Flowmeter

 

  • We have been in this business for more than ten years.
  • Our customer satisfaction is 99. 5%.
  • We are located in Kaifeng, the most ancient and biggest base of flow instrument in China, which means we have full acc ess to the most advanced technologies in this field.
  • We are awarded ISO9001:2008.
  • Our belief is "Accuracy and Attitude, Access to Customer".
  • Our monthly output of electromagnetic flow meters is 3000 sets.
  • We are able to provide electromagnetic flow meters with international standards.
  • Our goal is to make world wide brand.
Our Services

 

Our Services--Water Electromagnetic Flowmeter

1. The measured fluid must be conductive

2. The measured fluid must be full of the pipeline

3. The medium temperature must be below 180°C.

4. There should be none electromagnetic interference(including center control room, frequency converter, high voltage, etc) nearby electromagnetic flow meter.

 If necessary, please note:

A: the parameters like upper limit value of flow range or the relevant flow rate that need to be set before the flowmeter ex-work;

B: whether there is a requirement of immersing usage;

C: whether there is a requirement of providing companion vice flange for installation;

D: please consult with us when you have any special needs.

 
FAQ

FAQ--  Water Electromagnetic Flowmeter

 

Selection of Nominal Diameter--Water Electromagnetic Flowmter

As electromagnetic flowmeter has a high rangeability of 1500:1, the selection of nominal diameter is the same as that of process pipe;

 

 

If there are solid particle in the measured medium, a flow rate range of 1~3m/s is recommended. If the practical flow rate is excessive yet inconvenient to adjust, the nominal diameter of the instrument is better larger than that of the process pipe, under which condition the flow rate in the measuring pipe of the flowmeter can be properly decreased and the abrasion of electrode and liner caused by the particle can be alleviated;

 

If there are sediment in the process pipe, a flow rate range of 1~3m/s is recommended. If the practical flow rate is too little, the nominal diameter of the instrument is better smaller than that of the process pipe in order to properly increase the flow rate of the fluid in the flowmeter to avoid the effect on the accuracy caused by the sediment.

 

If the flow rate is too little yet a high precision measurement is required, a sensor smaller than the nominal diameter can increase the flow rate to ensure high precision.

 

In the above 2,3,4 conditions, a reducing pipe should be jointed to both the upstream and downstream of the flowmeter. The center taper angle should be no more than 150 and there should be a straight pipe at least 5 times of the the process pipe jointed to the reducing pipe.

 
Packaging & Shipping

Packaging & Shipping--Water Electromagnetic Flowmeter

cheap industrial water electromagnetic flowmetercheap industrial water electromagnetic flowmeter

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2006
Factory Size
10,000-30,000 square meters
Total Employees
101 - 200 People

Recommended Categories