Home > Products > Tempaerature Controller > 12v dc temperature controller
12v dc temperature controller
- 100000 Set / Sets per Month
- Shanghai
- Credit Card
Product Details
Place of Origin: | Jiangsu, China | Brand Name: | no | Model Number: | D10 |
Usage: | Industrial | Theory: | Temperature Sensor |
Product Description
Specifications
Temperature display, temperature controlling,compressor start delay protection, 2 defrost modes (electric heat, hot gas),
Main Function
Temperature display, temperature controlling, compressor start delay protection, 2 defrost modes (electric heat, hot gas), 2 defrost start mode (time alternation, accumulative compressor running time), 2 defrost end mode (timing, controlled by both temperature and time), dripping, manual defrost, sensor error alarm, one external alarm input, password, probation time.
Technique Index
1,Temperature display range: -50~150°C(The resolution is 0.1°C)
2,Power supply: AC 220V±10% or AC 380V±10% 50Hz (Refer to the wiring diagram)
3,Operating environment: temperature -20°C~50°C, humidity≤85%
4,Relay contact capability: 8A/250VAC (pure resistive load)
5,Temperature sensor: NTC R25=5kΩ, B (25/50) =3470K
Operating Guide
1, Meaning of the index lights on the panel
Index light | Name | Light | Flash |
| Upper Temp | In the state of setting | - |
| Bottom Temp | In the state of setting | - |
| Refrigeration | Refrigerating | Ready to refrigerate, in the state of compressor start delay protection |
| Defrost | Defrosting | Dripping or the state of compressor start delay protection |
2,Meaning of the LED display
The LED usually shows temperature, if it shows “SHr”, it means the temperature sensor is short, and “OPE” means the temperature sensor is open. The temperature and the alarm code (Axx) will show alternately when in the alarm state. The code is showing below:
Code | Meaning | Explanation |
A11 | External alarm | Alarm from external alarm signal, refer to the internal parameter code “F50” |
A21 | Temperature sensor error | Open or short(showing “OPE” or “SHr”) |
A22 | Evaporator sensor error | Open or short(showing “OPE” or “SHr” when press the key “6”). If you don’t need to use the evaporator sensor, you can use the F59 to close the alarm. |
A99 | Over probation time | If you have set the probation time F87, the alarm occurs when the accumulative running time is over probation time, and the controller can not work. |
3,The temperature of the evaporator sensor display
When displaying current temperature, press “6” key, the controller will display evaporator temperature. Loose “6” key, then return to current temperature. Notice that if you press the key and hold it for 5 seconds, the controller will enter or exit the defrosting state forcibly.
4,Set temperature
When displaying current temperature, press the key “5” “6” at the same time, then enter the state of upper temperature setting, the LED displays the upper temperature, then using “5” key or “6” key can change the parameter(the key “5” adds 0.1°C, the key “6” minuses 0.1°C, press and hold it over 0.5 seconds can add or minus rapidly). After setting, press the key “5” “6” at the same time, then enter the state of bottom temperature setting, using the same way set the bottom temperature, then exit the state of parameter setting.
Contact Us
- Suzhou Chuangtai Electronics Co., Ltd.
- Contact nameAndy Ting
- Phone86-512-53111981
- AddressNo. 38, Gugang Road, Taicang
Infrared Thermometer | New Products | NTC Senor | Protector |
Tempaerature Controller | Temperature controller | Temperature&Humidity Recorder | Water Heater Controller |
- Power IEC104 protocol server client master and slave protocol debugging software tool
- Intelligent temperature switch
- WARTSILA CABLE SET CABLE CONNECTOR AS and Temperature sennsor HT water and fuel oil
- TMB 5210 Rosemount Tank Radar AB Sweden
- Intelligent switch series
- temperature pressure transmitter
- Thermocouple WRNK2-332 power plant spare parts
- Impactor Monitoring Gauge RZQW-03A for power generation
- Armour Thermocouple WRNK2-231 for power station
- Fire prevention thermal imaging camera temperature measurement fire alarm forestry warehouse fire prevention
- USA original BENTLY 3500/44-01-00
- Carel refrigeration thermostat PJEZY0H000 cold storage controller
- Carel refrigeration thermostat PJEZS2P010 cold storage controller
- Carel refrigeration thermostat PJEZS0H000 cold storage controller
- Carel refrigeration thermostat PJEZS00000 cold storage controller
- Carel refrigeration thermostat PJEZC0P000 cold storage controller
- Carel refrigeration thermostat PJEZC0H000 cold storage controller
- Carel refrigeration thermostat PJEZC00000 cold storage controller
- Carel multi-parallel refrigerator controller MX30M25H00 temperature controller MPX PRO
- 698 photovoltaic protocol converter photovoltaic inverter power generation electricity consumption information collection
- New York Inspiration Temperature Sensor, Model 025W39721-302
- Repair of the exhaust temperature probe of the new York temperature sensor 639A0151H01 compressor condensing unit
- USA original bently nevada 330171-00-08-10-02-00 330173-00-05-10-12-00 330172-16-42-10-01-00
- USA original bently nevada 330130-040-00-00 330130-085-00-05
Popular Searches
- phone logger
- recorder
- thermometer hygrometer
- Bath Thermometer Strip
- data measurement
- recorders
- Temperature Data Logger
- digital thermostat
- fan thermostat
- control thermostat
- temperature recorder
- temperature humidity data logger
- data recorder
- Humidity Data Logger
- Usb Data Logger
- Thermometer Data Logger
Recommended Products
- ASTM D2602 Full Automatic CCS Cold Cranking Simulator Apparent Viscosity of Engine Oils Tester (16 test units)
- ASTM D1551 Sulfur Content of Petroleum Products Tester (Tubular Furnace Method)
- ASTM D5182 FZG Gear Oil Wear Testing Machine
- ASTM D1534 Auto Acid Number in Transformer and Turbine Oils in Service by BTB Method
- High Quality DIN Abrasion Tester Sole Rubber Abrasion Test Machine Sole Wear Testing Equipment
- DIN-53516 Shoes DIN Abrasion Tester Rubber Abrasion Resistance Test Machine DIN Wear Testing Equipment
- DOPPEL new arrival DPLLD series plug-in electromagnetic flowmeter DN10-DN3000 0.6MPa 1.0MPa 1.6MPa 4.0MPa
- ASTM D5264 Ink Rub Abrasion Tester Ink Rub Resistance Test Machine Paper Friction Testing Equipment
- JY-1035 Ink Rub Resistance Tester Ink Decolorizing Test Machine Ink Printing Abrasion Test Equipment
- Portable Textile Moisture Meter KMS680T
- High Precision Dichroic Optical Glass Prism, Right Angle Beam Splitter Lens
- Optical glass custom 90 degree silicon quartz right angle prism
Find Similar Products By Category
- Measurement & Analysis Instruments > Temperature Instruments
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy Ting
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-