Home > Instruments & Meters > Meter for Electricity > Energy Meter & Power Meter > Electricity Three Phase Eletronic Prepaid Energy Meter

Electricity Three Phase Eletronic Prepaid Energy Meter

Electricity Three Phase Eletronic Prepaid Energy Meter photo-1
US$ 2 - 55 MOQ: 500 Pieces
Key Specifications
Get Latest Price
Place of Origin:
Zhejiang, China
Brand Name:
Sirode or TFELE
Model Number:
Prepaid Energy Meter(TF22)
Payment & Shipping
Payment Methods:
Port of Shipment:
Ningbo Port
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Zhejiang, China
Brand Name Sirode or TFELE
Model Number Prepaid Energy Meter(TF22)
Display Type Analog and Digital
Phase Single Phase
Measuring Energy Range Muli current data
Accuracy Class Class 1 and Class 2, 1.0;2.0
Output Voltage 200-250V
Operating Temperature 70℃
Dimensions 112x164x60mm

Specifications

Prepaid Energy Meter
1)Good quality&best price
2)Simple structure,high reliability
3)Factory supply
4)Easy intallation

 

Introduction

 


DTSY794 Type Three-Phase Electronic Prepaid Energy Meter adopts microelectronic technology and comply with technical requirements for single phase electronic watt-hour meter stipulated in GB/T 17215.321-2008 and GB/T18460-2001. It apopts fully shielded, fully sealed structure and uses advance SCM processing systems for data collection, process and preservation...It also features good resistance to electromagnetic interference, low self-consumption of energy-saving, high accuracy, without calibration, burglar-proof electricity, high overload and long life etc...Meanwhile it provides fully functional managements software system of selling power.


Functions and features

1)Computer manage the system,users must purchase the electricity before use.
2)Active single-phase electric power metering,no subject to adjust in terms of long working
3)Function of transfer,cancel account,tempoary stop and rebate electricity bill(Especiall apply for comercial users)
4)Once the electric consumption available out,it should be cut off automatically.
5)Cut off power supply when over load
6)Fault self-diagnosis function,the diagnosis range from load switch,EEPROM TO THE IC CARD DATA
7)Support large capacity of reading meter,once card can read 160 users electricity consume data
8)Large screen LCD Display 
 


Feature and Benefit
Plug and play communication module
Build-in connect/disconnect latching relay
Remote/local firmware update
DLMS/COSEM compliance
Anti-tamper feature

Specification
Measurement
Class1.0/class B for active energy
Class 2.0/class A for reactive energy
With IEC 62052-11, IEC 62053-21, IEC 62053-23 and EN50470-1/3

Measured Value
Import and export energy (active and reactive)
Instantaneous voltage/current/active power/reactive power/frequency
Power factor (or phase anger)
Maximum demand (optional)

Current
Current range: 5/100A, 10/120A
Short time over current: 30 times Imax for 0.5 cycles
Burden: <0.02VA/phase @Ib

Voltage & Power Supply
Nominal voltage: 120V, 220V or 230V
Burden: <10VA/phase@ Un, 2W
Rated frequency range: 50Hz or 60Hz

Disconnection/Connection
Maximum switching voltage: 400 V Ac
Maximum switching current: 120 A
Maximum switching power: 48 kW

Environment
Operating temperature: -25° C to +70° C
Storage temperature: -40° C to +85° C
Relative humidity: ≤ 95%, non-condensing
Ingress protection: IP54 (without suction)


Security
Three-level security password protection
Cover open detection
Data encryption(optional)

Communication
Optical port according to IEC 62056-21 Mode C/E
RS485 and/or RS232
PLC(G3/PRIME), Zigbee and/or GPRS module

Protocol
IEC62056 - DLMS/COSEM

 

 

 

single phase energy meter

Feature and Benefit
Plug and play communication module
Build-in connect/disconnect latching relay
Remote/local firmware update
DLMS/COSEM compliance
Anti-tamper feature

Specification
Measurement
Class1.0/class B for active energy
Class 2.0/class A for reactive energy
With IEC 62052-11, IEC 62053-21, IEC 62053-23 and EN50470-1/3

Measured Value
Import and export energy (active and reactive)
Instantaneous voltage/current/active power/reactive power/frequency
Power factor (or phase anger)
Maximum demand (optional)

Current
Current range: 5/100A, 10/120A
Short time over current: 30 times Imax for 0.5 cycles
Burden: <0.02VA/phase @Ib

Voltage & Power Supply
Nominal voltage: 120V, 220V or 230V
Burden: <10VA/phase@ Un, 2W
Rated frequency range: 50Hz or 60Hz

Disconnection/Connection
Maximum switching voltage: 400 V Ac
Maximum switching current: 120 A
Maximum switching power: 48 kW

Environment
Operating temperature: -25° C to +70° C
Storage temperature: -40° C to +85° C
Relative humidity: ≤ 95%, non-condensing
Ingress protection: IP54 (without suction)


Security

Three-level security password protection
Cover open detection
Data encryption(optional)

Communication
Optical port according to IEC 62056-21 Mode C/E
RS485 and/or RS232
PLC(G3/PRIME), Zigbee and/or GPRS module

Protocol
IEC62056 - DLMS/COSEM

 

 

 

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2008
Factory Size
5,000-10,000 square meters
Total Employees
201 - 300 People

Recommended Categories

Explore top categories and find suppliers for your specific needs