US$ 1 - 3 MOQ: 16 Meters
Key Specifications
Get Latest Price
Place of Origin:
Anhui, China
Brand Name:
Minco
Model Number:
Twin conductor heating cable
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai Nanjing
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Anhui, China
Brand Name Minco
Model Number Twin conductor heating cable
Insulation Material XLPE
Type Low Voltage
Application Construction
Conductor Material Copper
Jacket PVC

Wood Floor Heating System Underfloor Heating Cable

Product description:

 

Minco intelligent electric heating system is highly efficient, energy-saving, concealed low-temperature radiant soil warmming system. It is charcterized by green and environment-friendliness, energy conservation, low cost of installation and maintenance,etc.  The good reason to rate is as the best choice to bring you enjoying walking and safety when going outside!

 

Details:

 

Brand: Minco     Type:Low voltage twin conductor heating cable     Linear Power:18.5W/M    

 

Voltage:220V     Color:Blue     Warranty:10 years     Life span:50 years

 

Certification:CE,GOST,ROHS,FIRE RESISTANT

 

 

Structure:

 

single conductor heating cable:

 

 Wood Floor Heating System Underfloor Heating Cable

 

 

 

1.Heating alloy wire 

Series structure without  voltage drop;

the temperature of whole cable is even.  

2.Silane crosslinked polyethylene insulation

The long-term working temperature is 105°C

The instantaneous overload temperature is 205°C 

3.Ground wire 8 tin plated copper wires with a diameter of 0.4mm
4.Thickened metal electromagnetic shielding layer Thichened Aluminum composite membrane shielding layer can shield the electronmagnetic radiation effectively which already passed the American electronmagnetic radiation detection and the European U nion CE certification.
5.Flame-retardant PVC sleeves Safe and environmental
   

 

 

 

Specifications:

 

                   TXLP/2R series twin conductor Electric Heating Cable(220V 18.5W/M)

Power(W)

Cable model Voltage(V) Standard length(M) Power per meter(W/M) Total value of resistance(Ω)
     3150 TXLP/2R/18.5       220         170.3            18.5               15.4
     2800 TXLP/2R/18.5       220         151.4            18.5               17.3
     2600 TXLP/2R/18.5        220         140.5            18.5               18.6
     2400 TXLP/2R/18.5       220         129.7            18.5               20.2
     2200 TXLP/2R/18.5       220         118.9            18.5               22.0
     2000 TXLP/2R/18.5       220         108.1            18.5               24.2
     1800 TXLP/2R/18.5       220           97            18.5               26.9
     1600 TXLP/2R/18.5       220           86            18.5               30.2
     1370 TXLP/2R/18.5       220          74.1            18.5               35.3
     1250 TXLP/2R/18.5       220          67.6            18.5               38.7
     1000 TXLP/2R/18.5       220          54.1            18.5               48.4
      840 TXLP/2R/18.5       220          45.4            18.5               57.6
      700 TXLP/2R/18.5       220          37.8            18.5               69.1
      600 TXLP/2R/18.5       220          32.4            18.5               80.7
      500 TXLP/2R/18.5       220          27.0            18.5               96.8
      400 TXLP/2R/18.5       220          21.6            18.5              121.0
      300 TXLP/2R/18.5       220          16.2            18.5              161.3

 

 

 

Advantages: 
1.CE ROHS GOST and FIRE RESISTANT certificated.

 

2. 10 years warranty.

 

3. Almost 50 years lifespan.

 

4. A one-time investment, a lifetime of use. 

 

5. Eco-friendly, energy saving and no noice.

 

6. Controlled by MINCO programmable thermostat

 

7. Order cable, send thermostat  for free.

 

 

 

Application:

 

 

 

                                                    Floor heating

 

Wood Floor Heating System Underfloor Heating Cable

 

                                       Snow and ice melting

 

Wood Floor Heating System Underfloor Heating Cable

 

                                                Pipe insulation

 

Wood Floor Heating System Underfloor Heating Cable

 

 

 

NOTES:

 

1). Heating cable fix materials: Aluminum tape.
2). Cross tube materials: Use steel or PVC tube.

 

3). Don't damage cable. The bend radius should be more than 6 times of thickness of cable.

 

4). Heat insulation materials should be dry and the joint of cable should be sealed.
5). The junction box should be sealed.
6). Protective sleeve must not be damaged during installation, and the core wire 
can not bare.

 

7). The heating cable should be installed accurately according to the design graphics.

 

 

 

Certification:

 

Wood Floor Heating System Underfloor Heating CableWood Floor Heating System Underfloor Heating Cable

 

 

 

Methods of Payment:

 

Payment methods

Commission fee

Arriving days afer paying

             

No commission fee

3-5 working days

               

3.9%+0.3 usd

 

Instant

               

No commission fee

 

Instant

               

No commission fee

 

Instant

               

 

Alibaba calculate it

 

Instant

 

 

 

    More similar products, please visit: https://img13.fr-trading.com/

 

      We are the best in China!Welcome! My friends!

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Year Established
2013
Factory Size
Below 1,000 square meters
Total Employees
51 - 100 People