Factory Price no Pollution Small Poultry Incinerators for Sales Quality Choice
Factory price no pollution small poultry incinerators for sales
Descriptions of incinerator for poultry:
The animal carcasses incinerator is a kind of machine with compact size, high burning efficiency, reasonable burning technology, high degree of non-harm etc. It is an ideal choice for waste treatment of hospital, hotels, various stations and industries.
This waste incinerator is a kind of machine that possess the own intellectual property, features unique and advanced merits with compact size, high burning efficiency, reasonable burning technology, high degree of non-harm etc, it is an ideal choice for waste treatment of hospital, hotels, various stations and industries.
Technical Specification
Model |
WFS-30 |
WFS-50 |
WFS-150 |
WFS-300 |
WFS-500 |
Burning Capacity |
20-30kg/time (3-6 times/day) |
30-50kg/time (3-6times/day) |
100-150kg/time (3-6times/day) |
200-300kg/time (3-6times/day) |
300-400kg/ time (3-6times/day) |
Incinerator Size (L×H×B) |
1.45×0.9×1.75m |
1.8×1.15×3m |
2×1.4×3.5m |
2.2×1.4×3.8m |
3×2×4.8m |
|
Imputing Mouth Width |
480×600mm |
620×800mm |
760×960mm |
900×1100mm |
1080×1280mm |
Chimney External Diameter |
280mm |
280mm |
300mm |
400mm |
460mm |
Draught Fan |
0.37kw |
0.37kw |
0.5kw |
1.1kw |
1.1kw/0.55kw |
Combustion Burner |
0.11kw oil consumption 4-6kg/h |
0.11kw oil consumption 4-10kg/h |
0.11kw oil consumption 4-10kg/h |
0.22kw oil consumption 7-14kg/h |
0.22kw oil consumption 7-14kg/h |
Re-Burner |
0.11 kw oil consumption 4-6 kg/h |
0.11kw oil consumption 4-10kg/h |
0.22kw oil consumption 7-14kg/h |
0.37kw oil consumption 10-20kg/h |
0.37kw oil consumption 15-26kg/h |
Voltage |
380v/220v |
380v/220v |
380v/220v |
380v/220v |
380v/220v |
features of incinerator for poultry:
1) Both gas-motivated and oil-motivated are all can be preferred according to customers’ needs.
2) Gasified incineration is used for burning syringe, paper waste, bandage, absorbent cotton and other medical wastes.
3) Daily waste can be burned once by gasified incineration.
4) Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust (lower than International standard).
5) Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution

1) Long lifetime
2) Totally enclosed operation
3) Suitable for treating infectious waste
4) Avoid secondary pollution
5) Simple operation
Technological process:
1.This medical garbage incinerator is provided with the currently most advanced incineration way, i.e., primary pyrolysis gasification, co-firing of surrounding wind, secondary incineration, burnout treatment.
2.The primary incineration chamber of this incinerator is provided with the gasification incineration technique, which makes the temperature inside the incinerator rise from 200℃ to 400℃. The problems such as clinker, residue and sintering will never happen in the process of garbage incineration.
3.The secondary incinerator and toroidal air supply device are set inside the secondary mixed incineration chamber. The combustible gas in the smoke will be burnt fully under high temperature, which can burn the gas generated by the gasifier and air fully and effectively by mixing them and prevent the overflow of the carbon substances in gas and late incineration. The smoke enters the high-temperature incineration chamber tangentially and the combustion-supporting air also enters it in a tangential manner, making the smoke incinerate fully again in the incineration chamber.
4.The flue gas dust removal is made by the swirling air flow. The retention time of incineration smoke in the incinerator is greater than 2s, so that the combustible gas in smoke and the combustibles in the flying ash burn fully. Dry tail gas purification device is set in the upper part of the incinerator so as to absorb the chlorine hydride and oxysulfide generated by incineration. The odor in smoke will be decomposed under the high temperature.
5.The smoke purification system is provided with calcium hydride filter brick which will be involved in neutralization reaction with the acid gas in order to absorb the acid gas and purify the tail gas. The harmful components of the smoke are decomposed below the value specified in the national standard “Pollution Control Standard for Hazardous Wastes Incineration (GB18484-2001)”.
Application:
Hospital medical wastes: Bandage, Paper/ Injection Syringe/ Drop Bottle, expired drugs, infectious viscera, etc; Infectious disease animal body/fur/hair, widely used in pets carcasses disposal: pig, dog, cat, fish, chicken, cattle, duck, etc; Domestic daily home wastes; Disposable plastic wastes; Some other industrial wastes
Send Inquiry to This Supplier
You May Also Like
-
200 kg Garden Rubbish Incinerator From China SupplierUS$ 1,000 - 30,000MOQ: 1 Unit
-
Medical Waste Incinerator Manufacturers for Hospital Garbage TreatmentUS$ 1,000 - 30,000MOQ: 1 Unit
-
Medical Incinerator Prices/electric IncineratorUS$ 1,000 - 30,000MOQ: 1 Unit
-
LDF Medical Solid Waste IncineratorUS$ 1,000 - 30,000MOQ: 1 Unit
-
50-80kg Cheap Medical Sanitary Napkin IncineratorUS$ 1,000 - 30,000MOQ: 1 Unit
-
Cheap Small Medical Incinerator PricesUS$ 1,000 - 30,000MOQ: 1 Unit
-
Smokeless Diesel Industrial Medical Waste Incinerator Price Quality ChoiceUS$ 1,000 - 30,000MOQ: 1 Unit
-
Smokeless Commercial Garbage IncineratorUS$ 1,000 - 30,000MOQ: 1 Unit
-
Factory Directly Medical IncineratorUS$ 1,000 - 30,000MOQ: 1 Unit
-
Good Quality Factory Directly Incinerator BurnerUS$ 1,000 - 30,000MOQ: 1 Unit