Allen-Bradley 2711P-B12C15D1 PanelView Plus 1250 HMI combines a 12.1-inch touchscreen with a 15-button keypad for flexible operation in harsh industrial settings. It offers robust connectivity (EtherNet/IP, serial), runs FactoryTalk View ME software, and provides clear process visualization. Ideal for seamless integration with Rockwell Automation systems, it enhances operator efficiency and system reliability.
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Application:
Other, Industrial Automation and Control
Brand:
Allen-Bradley (Rockwell Automation)
Model:
2711P-B12C15D1
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Application Other, Industrial Automation and Control
Brand Allen-Bradley (Rockwell Automation)
Model 2711P-B12C15D1
Series PanelView Plus 1250
Display Size 12.1 inches
Input Method Touchscreen and Keypad
Mounting Type Panel Mount
Display Type Color TFT LCD

As a trusted supplier with over a decade of industry experience, Rossonix Co., Limited is proud to offer the Allen-Bradley 2711P-B12C15D1 PanelView Plus 1250 operator interface. Operating from our strategic base in Shenzhen, we have successfully served a global clientele across North America, Europe, Asia, and beyond. This terminal represents a robust and versatile solution for demanding industrial environments, combining the intuitive operation of a touchscreen with the tactile reliability of a physical keypad. It is engineered to deliver clear visualization and reliable control for your critical automation processes.

The PanelView Plus 1250 series is designed for seamless integration into Rockwell Automation's control architecture, providing operators with a powerful window into machine and process data. Its dual-input capability ensures operational efficiency can be maintained even in challenging conditions where gloves are worn or precise touch input is difficult. We understand that uptime and operator confidence are paramount, which is why we supply this industrial-proven HMI.

Core Features and Technical Advantages:

  • Dual-Input Flexibility: Features a high-resolution 12.1-inch color touchscreen alongside a 15-button keypad. This hybrid design offers the best of both worlds: the speed and flexibility of touch navigation for complex screens and the positive, gloved-finger operation of physical keys for critical functions.
  • Rugged Industrial Design: Built to withstand harsh factory floor conditions, including vibration, electrical noise, and a wide operating temperature range. The panel-mount design ensures a secure and professional installation.
  • Enhanced Connectivity: Supports multiple communication protocols for direct connection to Allen-Bradley Logix controllers (via Ethernet/IP) and other industrial networks, simplifying system integration and reducing wiring complexity.
  • Powerful Runtime Software: Runs FactoryTalk View Machine Edition (ME) software, enabling the creation of dynamic, responsive graphical interfaces that display real-time data, alarms, trends, and diagnostics.
  • Superior Display Quality: The TFT LCD provides bright, clear graphics and text readability from wide viewing angles, even in well-lit environments, reducing operator eye strain.

Detailed Technical Specifications:

Parameter Specification
Product Model 2711P-B12C15D1
Display Size (Diagonal) 12.1 inches
Display Resolution 800 x 600 (SVGA)
Display Type Color Active Matrix TFT LCD
Input Methods Analog Resistive Touchscreen, 15-Function Keypad
Communication Ports Serial (RS-232), Ethernet (10/100 Mbps)
Primary Protocol EtherNet/IP
Memory 128 MB RAM (typical for runtime)
Mounting Panel Mount (NEMA 4/4X/12/13 rated when properly installed)
Power Supply 24V DC (standard for industrial applications)

Benefits for Your Operation:

  • Increased Operational Efficiency: The intuitive interface allows for faster machine setup, changeovers, and troubleshooting, minimizing downtime.
  • Improved Process Visibility: Real-time data display and historical trending help operators make informed decisions to optimize quality and throughput.
  • Enhanced Reliability: The combination of industrial-hardened hardware and proven Allen-Bradley software ensures stable, long-term performance in critical applications.
  • Reduced Training Time: User-friendly graphical screens are easier for new operators to learn and understand compared to text-based interfaces.
  • Future-Proof Investment: Part of the widely adopted PanelView Plus family, ensuring support, spare parts, and integration expertise are readily available.

Rossonix Co., Limited operates under ISO9001 quality management standards, ensuring consistent product sourcing and reliable service. With an annual export value in the multi-million dollar range and a presence in key global markets, we have the logistical capability to deliver this essential automation component to your facility, whether you are in North America, Europe, Oceania, or Asia. Our team leverages major ports like Shenzhen and Hong Kong for efficient worldwide shipment. Choosing the 2711P-B12C15D1 PanelView Plus 1250 is not just selecting an HMI; it's investing in a proven interface solution backed by global brand support and a supplier committed to quality. Contact us today to discuss your requirements, request a quotation, or learn more about our comprehensive range of industrial automation components.

Frequently Asked Questions (FAQ)

  • Q: What software is needed to create applications for this PanelView Plus 1250?
    A: Applications are developed using FactoryTalk View Studio software (Machine Edition). This software allows for the design, configuration, and testing of the graphical operator interface before downloading it to the terminal.
  • Q: Can this unit communicate with non-Allen-Bradley PLCs?
    A: While optimized for Rockwell Automation controllers via EtherNet/IP, its serial port supports other protocols like DF1 or Modbus RTU, enabling connectivity to some third-party devices, though additional configuration may be required.
  • Q: What is the difference between the 'P' model and other PanelView Plus models?
    A: The 'P' denotes a Panel-mount version. Other suffixes like 'C' may indicate a Console-mount version. The 1250 refers to the screen size category (in this case, 12.1-inch).
  • Q: Does it support remote access or diagnostics?
    A: Yes, via its Ethernet port. When integrated into a network, it can support remote viewing of screens (using VNC technology) and diagnostics, facilitating support from engineering or maintenance offices.
  • Q: What are the environmental ratings for this HMI?
    A: When properly installed with a sealed gasket, the terminal can achieve ratings such as NEMA 4/4X (water and dust ingress) and NEMA 12/13 (protection against oil and coolants), making it suitable for many industrial environments.
  • Q: Is the memory expandable?
    A: The runtime memory is fixed. For application storage, it typically uses non-volatile flash memory. The capacity is sufficient for most machine-level applications. Very large or complex projects should be evaluated during the design phase.
  • Q: Can I replace an older PanelView terminal with this newer Plus model?
    A: Often, yes. The PanelView Plus series is a modern successor to earlier PanelView Standard terminals. Migration involves recreating the application in FactoryTalk View ME software. Physical mounting cutouts and communication wiring may need verification.
  • Q: What power supply requirements does it have?
    A: It operates on a standard 24V DC industrial power supply. Ensuring a clean, stable power source within the specified voltage range is crucial for reliable operation.
Product Tags: Allen-Bradley PanelView Plus 1250 HMI , Rockwell Automation 12.1-inch Touchscreen Terminal , 2711P-B12C15D1 Operator Interface Panel

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Platinum Verified Supplier
1Yr
Verified Business License
Business Type
Trading Company
Year Established
2011
Overseas Office
Yes
Annual Export Value
US$5 Million - US$10 Million

Recommended Categories

Explore top categories and find suppliers for your specific needs