Home > Electrical & Electronics > Passive Components > Capacitor > Outdoor Tank-Type Circuit Breaker, SF6 Gas Pressure Monitoring & Self-Contained Design

Outdoor Tank-Type Circuit Breaker, SF6 Gas Pressure Monitoring & Self-Contained Design

Outdoor Tank-Type Circuit Breaker, SF6 Gas Pressure Monitoring & Self-Contained Design photo-1
Outdoor Tank-Type Circuit Breaker, SF6 Gas Pressure Monitoring & Self-Contained Design photo-2
Outdoor Tank-Type Circuit Breaker, SF6 Gas Pressure Monitoring & Self-Contained Design photo-3
Outdoor Tank-Type Circuit Breaker, SF6 Gas Pressure Monitoring & Self-Contained Design photo-4
Outdoor Tank-Type Circuit Breaker, SF6 Gas Pressure Monitoring & Self-Contained Design photo-5

Product Spotlights

Outdoor tank-type SF6 circuit breaker with integrated gas pressure monitoring for reliable fault protection. Self-contained design ensures easy installation and reduced maintenance. Suitable for harsh environments, it offers superior insulation and arc quenching. Features remote monitoring capability for smart grid integration. Built for durability and long-term performance in global power networks.
US$ 2000 - 5000 MOQ: 1 Piece
Key Specifications
Get Latest Price
Type:
Other, Outdoor Tank-Type SF6 Circuit Breaker
Application:
Other, Transmission & Distribution Substations
Rated Voltage:
Up to 72.5kV or higher (Customizable)
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Type Other, Outdoor Tank-Type SF6 Circuit Breaker
Application Other, Transmission & Distribution Substations
Rated Voltage Up to 72.5kV or higher (Customizable)
Rated Current 1250A, 2000A, 3150A (Available)
Interrupting Medium SF6 Gas Insulation & Arc Quenching
Operating Mechanism Spring or Hydraulic (Optional)
Control System Self-Contained with Local/Remote Monitoring
Gas Pressure Monitoring Integrated Digital or Analog Gauge
Installation Pole-Mounted or Ground-Based
Design Standard IEC 62271-100, ANSI C37.04 (Compliant)

As a dedicated manufacturer with ISO9001-certified processes, Jinhua Dika Electrical is committed to delivering robust and reliable high-voltage solutions for the global power industry. Our Outdoor Tank-Type SF6 Circuit Breaker, featuring integrated gas pressure monitoring and a self-contained design, represents a significant advancement in substation equipment. Engineered for demanding environments, this breaker ensures uninterrupted power distribution by providing superior fault protection and operational stability. We understand the critical need for safety and longevity in electrical networks, which is why our product is built to withstand harsh outdoor conditions while maintaining precise control and monitoring capabilities. With a focus on innovation and quality, we support utilities and industrial clients in enhancing grid resilience and operational efficiency.

This circuit breaker is designed as a complete, ready-to-install unit, significantly reducing on-site assembly time and complexity. Its tank-type construction houses all critical components, including the interrupter unit, operating mechanism, and control circuitry, within a sealed, weatherproof enclosure filled with SF6 gas. This design offers several key advantages:

  • Enhanced Reliability: The sealed system minimizes exposure to environmental contaminants like moisture, dust, and salt spray, which are common causes of insulation degradation and failure in outdoor applications.
  • Superior Dielectric Strength: SF6 gas provides excellent insulation properties, allowing for a more compact design compared to air-insulated breakers while maintaining high voltage withstand levels.
  • Efficient Arc Quenching: SF6 rapidly deionizes and cools the arc during circuit interruption, enabling fast fault clearing times and minimizing contact erosion.
  • Integrated Intelligence: The self-contained design includes local control, protection relays, and the crucial gas pressure monitoring system, offering a high degree of automation and remote management potential.

The core of its operational integrity lies in the SF6 Gas Pressure Monitoring System. Continuous monitoring of gas density and pressure is vital for several reasons:

  • It ensures the dielectric insulation remains at optimal levels for safe operation.
  • It verifies the gas volume is sufficient for effective arc quenching during a fault interruption.
  • It provides early warning of potential leaks through alarms or lockout signals, allowing for proactive maintenance before a critical failure occurs.

Our breakers are available in various configurations to match specific project requirements. Key technical specifications often include:

Parameter Typical Specification Range Notes
Rated Voltage (Ur) 36kV, 72.5kV, 145kV Higher ratings available upon request
Rated Normal Current (Ir) 1250A, 2000A, 3150A Standard values; custom ratings possible
Rated Short-Circuit Breaking Current (Isc) 25kA, 31.5kA, 40kA Meets most grid fault level requirements
SF6 Gas Pressure (at 20°C) 0.4 - 0.6 MPa (Nominal) Monitored continuously; alarm thresholds configurable
Mechanical Endurance 10,000 operations (M2 Class) Designed for long service life
Operating Mechanism Spring-operated or Hydraulic Choice based on speed and control preferences
Ambient Temperature Range -30°C to +40°C Suitable for diverse climatic conditions

For clients, the benefits translate into tangible operational and financial gains. Reduced maintenance costs are achieved through the sealed, low-wear design and proactive alerts from the monitoring system. The self-contained nature simplifies installation and commissioning, leading to faster project completion. Furthermore, the high reliability directly contributes to improved grid availability and reduced outage times, protecting revenue and service quality. The design's adaptability makes it suitable for a wide range of applications, from utility transmission lines and distribution substations to large industrial plants and renewable energy integration points.

Backed by our ISO9001 quality management system and an annual export volume demonstrating global trust, Jinhua Dika stands as a reliable partner in power infrastructure. Our products reach key markets across North America, Europe, Asia, and beyond, supported by efficient logistics from major ports like Shanghai and Tianjin. With a dedicated team of 11-50 professionals, we focus on engineering excellence and customer support. Choosing our Outdoor Tank-Type SF6 Circuit Breaker means investing in a product built for durability, equipped with intelligent monitoring for peace of mind, and designed to deliver secure and stable power distribution for years to come. We invite you to contact us for detailed technical consultations and to discuss how this solution can meet your specific project needs.

Frequently Asked Questions (FAQ)

  1. Q: What is the primary advantage of the tank-type design over other outdoor breaker types?
    A: The tank-type design encapsulates all live parts and the interrupting mechanism in a sealed, SF6-filled enclosure. This provides superior protection against weather, pollution, and physical damage, leading to higher reliability and lower maintenance in harsh outdoor environments compared to open or air-insulated designs.
  2. Q: How does the SF6 gas pressure monitoring work, and what happens if pressure drops?
    A: The breaker is equipped with a density gauge or pressure sensors that continuously monitor the SF6 gas. If the pressure drops below a pre-set warning level (indicating a potential leak), an alarm is triggered. If it falls to a critical lockout level, the system can prevent the breaker from operating to ensure safety, prompting maintenance.
  3. Q: Is special training required to operate or maintain this breaker?
    A: While the self-contained design simplifies operation via standard control interfaces, handling SF6 gas and performing internal maintenance require trained, certified personnel following specific safety and environmental procedures due to the gas's properties.
  4. Q: Can this breaker be integrated into a SCADA or smart grid system?
    A: Yes, absolutely. The self-contained design typically includes provisions for remote communication. Status signals (position, alarms, pressure) and control commands can be interfaced with substation automation systems using standard protocols like IEC 61850 or Modbus, facilitating smart grid integration.
  5. Q: What is the typical delivery lead time for a standard model?
    A: Lead times vary based on specifications and order volume. For standard ratings, it typically ranges from 8 to 12 weeks. We recommend discussing your project timeline with our sales team for an accurate schedule.
  6. Q: Are spare parts and technical support readily available?
    A: As the manufacturer, we maintain an inventory of critical spare parts like contacts, seals, and control modules. We provide comprehensive technical documentation and support to ensure the long-term performance of your equipment.
  7. Q: What environmental considerations are associated with SF6 gas?
    A: SF6 is a potent greenhouse gas. Our breakers are designed for maximum sealing integrity to minimize leakage. We advocate for proper handling, recycling, and eventual disposal/reclamation of the gas at the end of the equipment's life, in accordance with environmental regulations.
  8. Q: Can you provide customized solutions, such as different rated currents or special control voltages?
    A: Yes, customization is a key part of our service. We can adjust parameters like rated current, control voltage (DC or AC), communication interfaces, and even certain mechanical dimensions to better fit your specific substation layout and requirements.
Product Tags: Outdoor SF6 Circuit Breaker , Tank-Type High Voltage Breaker , Self-Contained Gas Circuit Breaker

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Manufacturer
Annual Export Value
US$1 Million - US$1.5 Million
Total Employees
11 - 50 People
Product Certifications
HACCP, TL900, QS9000, SA8000, ISO9001, ISO9004, ISO17799, ISO9000, ISO14000, ISO10441, ISO16949, TS16969, ISO19011:2000, OHSAS18001, Others

Recommended Categories

Explore top categories and find suppliers for your specific needs