Home > Chemicals > Fiberglass Products > Other Fiberglass Products > Quotation for Anti - Corrosion Construction of Acid - Containing Wastewater Pool in Xinjiang. Jizhou Yike Has 20 Years of Professional Construction Experience.

Quotation for Anti - Corrosion Construction of Acid - Containing Wastewater Pool in Xinjiang. Jizhou Yike Has 20 Years of Professional Construction Experience.

Quotation for Anti - Corrosion Construction of Acid - Containing Wastewater Pool in Xinjiang. Jizhou Yike Has 20 Years of Professional Construction Experience. photo-1
US$ 27.69 50 - 199 Square Meters
US$ 12.77 ≥200 Square Meters
Key Specifications
Get Latest Price
Business Type:
Other
Year Established:
2009
Annual Export Value:
US$1.5 Million - US$2.5 Million
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.

Scope of application for FRP wastewater tank anti-corrosion: Anti-corrosion construction for concrete treatment tanks, ditches, floors and walls that require protection against corrosion from strong acids and alkalis and other chemical solvents; various steel containers; the surface of various metal equipment foundations, etc. It is widely applicable to acid, alkali and salt-resistant workshops, warehouses, storage tanks, walls, floors, sewage treatment tanks and other facilities in industries such as medicine, chemical industry, machinery, light industry, electronics, power plants, battery factories, electroplating factories, aluminum factories, and metallurgical factories.

Anti-corrosion process: Epoxy resin, vinyl resin, unsaturated resin FRP anti-corrosion lining: The anti-corrosion and waterproof lining is made of resin and glass fiber cloth. Specific FRP anti-corrosion practices include one layer of cloth and three coats of paint (also known as one layer of cloth and three coatings, one layer of cloth and three glues), two layers of cloth and four coats of paint (coatings, glues), three layers of cloth and five coats of paint (coatings, glues), four layers of cloth and six coats of paint (coatings, glues), five layers of cloth and seven coats of paint (coatings, glues), six layers of cloth and eight coats of paint (coatings, glues), seven layers of cloth and nine coats of paint (coatings, glues), eight layers of cloth and ten coats of paint (coatings, glues), nine layers of cloth and eleven coats of paint (coatings, glues), ten layers of cloth and twelve coats of paint (coatings, glues), etc. (and so on, the number of coats of paint, coatings, and glues is two more than the number of layers of cloth).

FRP anti-corrosion manufacturer,Jizhou Yike FRP, as the most professional FRP anti-corrosion construction expert, has maintained good cooperative relationships with large enterprises such as Guangzhou Shipyard, Daya Bay Nuclear Power Station, Dongguan Nestle, Huizhou BYD, and Jiangmen Electroplating Base in recent years. It has achieved great results in the field of FRP anti-corrosion projects and has been well-received by customers.

 Sewage and wastewater treatment tanks (such as FRP anti-corrosion for regulating tanks, neutralization tanks, oxidation tanks FRP anti-corrosion, anaerobic tanks, sedimentation tanks, electrolytic tanks FRP anti-corrosion, oil separation tanks, etc.). In sewage and wastewater treatment tanks, since the sewage and wastewater contain a large amount of corrosive media, such as waste acids and oxidizing chemicals, the corrosion to the treatment tanks based on concrete is relatively large. For concrete treatment tanks without anti-corrosion treatment, generally, the surface of the tank will be damaged and the strength will decrease significantly within 2 - 3 months. Therefore, anti-corrosion treatment must be carried out on the treatment tanks with a concrete foundation.

The construction of FRP acid and alkali anti-corrosion projects should comply with the following regulations: 

Sealing layer: On the treated base surface, the sealing primer should be evenly painted, and there should be no defects such as missed coating or sagging. The natural curing time should not be less than 24 hours. 

Repair layer: For the uneven depressions on the base layer, resin mortar should be used for repair and leveling. The natural curing time should not be less than 24 hours. For phenolic fiberglass or furan fiberglass, the mortar of epoxy resin, vinyl ester resin, or unsaturated polyester resin can be used to repair and level the base layer. 

 In sewage and wastewater treatment tanks (such as adjustment tanks, neutralization tanks, oxidation tanks, anaerobic tanks, sedimentation tanks, electrolytic tanks, oil separation tanks, etc.), since the sewage and wastewater contain a large number of corrosive media, such as waste acids and oxidizing chemicals, the corrosion to the treatment tanks based on concrete is relatively large. For the concrete treatment tanks without anti - corrosion treatment, in general, the surface damage and significant strength reduction of the tanks will occur within 2 - 3 months. Therefore, anti - corrosion treatment must be carried out on the treatment tanks with a concrete foundation.

Fiberglass anti - corrosion lining This is the most common anti - corrosion treatment method. It uses the glass fiber reinforced plastic (commonly known as "fiberglass") structure to form a protective layer on the concrete foundation. The fiberglass anti - corrosion lining has the characteristics of integrity, good impermeability, and reasonable cost. At the same time, selecting appropriate anti - corrosion resin can achieve good anti - corrosion effects. In the fiberglass lining anti - corrosion construction method, a composite structure of glass fiber cloth plus glass fiber chopped strand mat or surface mat is generally used, with a thickness between 1 - 3 mm.

The fiberglass anti - corrosion lining has the advantages of long - term water immersion resistance, low water permeability, strong adhesion, high water pressure resistance, acid and alkali corrosion resistance, anti - corrosion and anti - mildew, non - toxic and harmless, long service life, simple construction, and no need for a protective layer.

 


Product Tags: Wastewater tank anti-corrosion , FRP anti-corrosion construction , FRP anti-corrosion manufacturer

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Platinum Verified Supplier
1Yr
Verified Business License
Business Type
Other
Year Established
2009
Annual Export Value
US$1.5 Million - US$2.5 Million
Product Certifications
Others

Recommended Categories

Explore top categories and find suppliers for your specific needs