2000A 126KV Outdoor SF6 Gas Circuit Breaker for Power Grid Applications
Product Spotlights
As a trusted manufacturer with ISO9001 certification, Jinhua Dika Electrical Equipment Co., Ltd. proudly presents its 2000A 126KV Outdoor SF6 Gas Circuit Breaker. Engineered for demanding power grid applications, this breaker ensures reliable operation in diverse environmental conditions. With over US$1 Million in annual exports and a presence across five continents, our solutions are proven in global infrastructure projects.
Core Technical Specifications:
- Designed for high-voltage transmission networks requiring robust interruption capabilities.
- SF6 gas insulation provides superior dielectric strength and arc-quenching performance.
- Weatherproof construction withstands extreme temperatures (-30°C to +40°C operational range).
Key Parameters Table:
| Parameter | Value |
| Rated Short-Circuit Breaking Current | 40 kA |
| Mechanical Life | 10,000 operations |
| Control Voltage | DC 110V/220V (Standard) |
Operational Advantages:
- Modular design simplifies maintenance and reduces downtime
- Integrated pressure monitoring ensures gas integrity
- Anti-condensation heaters prevent moisture-related failures
Our 11-50 employee team provides responsive support from design to delivery. With shipments routed through Shanghai, Tianjin, Guangzhou, and Ningbo ports, we efficiently serve clients in North America, Europe, Asia, and beyond. This breaker’s field-proven durability in Eastern European winters and Southeast Asian humidity makes it a strategic asset for grid operators.
FAQ Section:
Q: What maintenance intervals are recommended?
A: We recommend inspection every 5 years or 2,000 operations with remote monitoring options.
Q: Is anti-seismic capability included?
A: Standard models meet IEC 62271-300 seismic requirements; enhanced designs are customizable.
Q: Can this integrate with existing SCADA systems?
A: Yes, it supports IEC 61850 communication protocols upon request.
Q: What is the lead time for delivery?
A: Standard units ship in 8-10 weeks; expedited production is available.
Q: Are installation services provided?
A: We offer global commissioning support through certified partners.
Q: How does SF6 gas handling comply with environmental regulations?
A: Our sealed-for-life design minimizes leakage below 0.5% per year, exceeding IEC standards.
Send Inquiry to This Supplier
You May Also Like
-
40.5kV SF6 Circuit Breaker LW8 Series With 5-Year Mechanical WarrantyUS$ 3000 - 9000MOQ: 1 Unit
-
LW8A-40.5/1600 Outdoor High Voltage SF6 Circuit Breaker 1600A 40.5kV Three-PhaseUS$ 3000 - 9000MOQ: 1 Unit
-
Three-Phase Outdoor Circuit Breaker LW8A/LW8 Compliant With IEC 62271 StandardsUS$ 3000 - 9000MOQ: 1 Unit
-
LW8A-40.5/1600 Circuit Breaker for Power Transmission Grids 40.5kV 1600AUS$ 3000 - 9000MOQ: 1 Unit
-
Three-Phase Outdoor SF6 Circuit Breaker LW8 Series 40.5kV 1600A-2000A RatingUS$ 3000 - 9000MOQ: 1 Unit
-
LW8-40.5/2000 High Voltage Breaker for Wind Farm Substations 2000A RatingUS$ 3000 - 9000MOQ: 1 Unit
-
40.5kV High Voltage Circuit Breaker LW8A-1600A & LW8-2000A With SF6 InsulationUS$ 3000 - 9000MOQ: 1 Unit
-
LW8-40.5/2000 Three-Phase SF6 Circuit Breaker 2000A 40.5kV for SubstationsUS$ 3000 - 9000MOQ: 1 Unit
-
LW36-40.5/126 Outdoor High-voltage 110KV SF6 Circuit Breaker for Power Transmission LinesUS$ 3500MOQ: 1 Unit
-
LW36-40.5/126 SF6 Outdoor High-voltage 110KV Circuit Breaker With 5-Year WarrantyUS$ 3500MOQ: 1 Unit



