Merck0.1%standard Water Sample 1.88051.0010 Karl Fischer Reagent From Germany
Product Spotlights
German Merck/Merck Standard Water Sample, Article Number: 1.88051.0010, Coulometric Determination
Concentration: 1 g ≙ 1 mg H₂O
Technique: Coulometric Determination
Density: 1.19 g/cm3 at 20 °C
Storage Temperature: 15 - 25°C
The concentration (efficiency) of Karl Fischer titrant decreases over time. Therefore, the titer, as a correction factor to offset this effect and the variations in equipment, personal operation, and laboratory conditions, must be determined immediately after opening a new bottle and should be verified regularly.
Product Name
Water Standard 0.1%, for Coulometric Determination, Certified Reference Material for coulometric Karl Fischer Titration 1 g ≙ 1 mg H₂O Aquastar®
Grade
certified reference material
Quality Level
300
Agency
ISO 17025, 17034
Product Line
Aquastar®
Form
liquid
Autoignition Temperature
287 °C (Information refers to the main component.)
expl. lim.
1.7 - 11.5 % (v/v) Information refers to the main component.)
Reaction Suitability
reaction type: water standard for Karl Fischer titration
Packaging
ampule of 10 × 8 mL
Technique
Karl-Fischer titration: suitable
titration: suitable
Boiling point
119 °C/1013 hPa
Transition temperature
flash point 31 °C (Information refers to the main component.)
Density
0.92 g/cm3 at 20 °C
Packaging form
single component solution
Storage temperature
15-25°C
General description
The 0.1% water standard is prepared by gravimetry using high-purity water and reagents. It is characterized by a DIN EN ISO/IEC 17025 accredited quality control (QC) laboratory. The moisture content of the standard is determined by direct coulometric Karl-Fischer titration according to ISO 760.
Please browse the ISO certificate and on-site quality self-assessment to view the current certification of analysis.
Download the certificate at to view the certified values, including uncertainty and expiration date.
Applications
This product can be used as a certified reference material (CRM) to verify the accuracy of Karl-Fischer coulometric titrators in accordance with the requirements of ISO 9001 7.1.5 "Monitoring and measuring resources". It can also be used to check the accuracy of the measurement results according to the European Pharmacopoeia 2.5.32 "Determination of water (micro determination)". Although it is more suitable for coulometric methods, it can also be used to verify low water content determined by volumetric methods.
Features and advantages
Convenient 8 mL glass ampoule packaging, with 10 disposable ampoules per box
Provides a batch-specific certificate of analysis (CoA), with accurately determined batch water content data, analysis method, NIST batch, and minimum shelf life
Tested and verified by ISO/IEC 17025 and ISO 17034 certified laboratories
It can be directly traced back to the SI unit (kg) and verified by NIST SRM 2890
Packaging
If the last digit of the product packaging code (SKU-pack size number) is "3", such as xxxxxx1003 or xxxxxxx 4003, it represents a SmartChemical product. Data can be seamlessly transmitted to the instrument via the RFID tag on the product label. For details, please refer to /SmartChemicals.
Analysis Instructions
Content determination (H₂O): 0.970 - 1.030 mg/g
|
Order N.O Order Number |
PACK Packaging |
Product Name |
Product Name |
||||
1.88005.0500 |
500ML |
apura-CombiTitrant 5 , 1ml--5mg H2O |
Single-component titrant 1ml--5mg H2O |
||||
1.88005.1000 |
1L |
apura-CombiTitrant 5 , 1ml--5mg H2O |
Single-component titrant 1ml--5mg H2O |
||||
1.88002.0500 |
500ML |
apura-CombiTitrant 2 single , 1ml--2mg H2O |
Single-component titrant 1ml--2mg H3O |
||||
1.88002.1000 |
1L |
apura-CombiTitrant 2 single , 1ml--2mg H2O |
Single-component titrant 1ml--2mg H3O |
||||
1.88001.0500 |
500ML |
apura-CombiTitrant 2 single , 1ml--2mg H2O |
Single-component titrant 1ml--1mg H4O |
||||
1.88001.1000 |
1L |
apura-CombiTitrant 2 single , 1ml--2mg H2O |
Single-component titrant 1ml--1mg H4O |
||||
1.09248.1000 |
1L |
Karl Fischer reagent 5 single component reagent w |
Single-component titrant 1ml--5mg H5O containing pyridine |
||||
1.88008.1000* |
1L |
apura-CombiSolvent methanol-free |
Single-component solvent, methanol-free |
||||
1.88020.1000* |
1L |
apura-Solvent for the one component titration for |
Single-component solvent, specially for oils |
||||
1.88021.1000* |
1L |
apura-Solvent for the one component titration for |
Single-component solvent, specially for edible oils |
||||
1.88010.0500 |
500ML |
apura-Titrant 5 , 1ml--5mg H2O |
Two-component titrant, 1ml--5mg H2O |
||||
1.88010.1000 |
1L |
apura-Titrant 5 , 1ml--5mg H2O |
Two-component titrant, 1ml--5mg H2O |
||||
1.88011.0500 |
500ML |
apura-Titrant 2 , 1ml--2mg H2O |
Two-component titrant, 1ml--2mg H3O |
||||
1.88011.1000 |
1L |
apura-Titrant 2 , 1ml--2mg H2O |
Two-component titrant, 1ml--2mg H3O |
||||
1.88015.1000 |
1L |
apura-Solvent for the two component titration |
Two-component solvent |
||||
1.88016.1000 |
1L |
apura-Solvent for the onetwo component titrati |
Two-component solvent, specially for oils and fats |
||||
1.09257.0508 |
500ML |
apura-CombiCoulomat fritless for cells withw |
Coulometric reagent (specially for diaphragmless cells) |
||||
1.09255.0508 |
500ML |
Apura-CombiCoulomat frit |
Coulometric reagent (for diaphragm reaction cell) |
||||
1.88050.0010 |
10x8ml |
apura-Water Standard 0.01% |
Standard water sample 0.1% |
||||
1.88051.0010 |
10x8ml |
apura-Water Standard 0.1% |
Standard water sample 1% |
||||
1.88052.0010 |
10x8ml |
apura-Water Standard 1% |
Standard water sample 1% |
||||
1.09259.0250 |
250ml |
apura-Water standard (1 ml contains 5mg H2O) |
Standard water sample 0.06% |
||||
1.12939.0010 |
10g |
apura-Lactose standard 5% solid standard for C/V/O |
Standard water sample 0.07% |
||||
1.06664.0100 |
100g |
apura-Sodium tartrate dihydrate volumetric standar |
Sodium tartrate dihydrate |
1.05704.0250 |
250g |
Molecular sieve 0.3 nm beads about 2 mm LAB |
Molecular sieve 0.3nm |
Karl Fischer single-component reagent |
Product number |
Usage |
Advantages |
|
Apura-CombiTitrant5 5-equivalent single-component titrant |
1.88005.1000 |
The most widely used reagent 1ml titrates 5mgH2O |
1. Faster titration; 2. Clearer titration endpoint; 3. Unchanged commitment and consistent high quality; 4. Non-toxic mixed solution, safer; 5. The solvent can be adjusted according to different samples. |
|
Apura-CombiTitrant2 2-equivalent single-component titrant |
1.88002.1000 |
More suitable for titrating samples with less water content 1ml titrates 2mgH2O |
|
|
Apura-CombiTitrant1 1-equivalent single-component titrant |
1.88001.1000 |
Suitable for samples containing trace amounts of water 1ml titrates 1mgH2O |
|
|
Apura-CombiSolwent Single-component solvent |
1.88008.1000 |
Does not contain methanol, meeting the requirements of faster and more accurate single-component titration |
|
Single-component special solvent containing methanol |
1.88009.1000 |
Water content is not more than 0.01% |
|
|
CombiMethanol dried (max.0.0005%H2O), SeccoSolv Anhydrous Methanol (Water content less than 0.0005%) |
1.06012.0500 |
Water content no more than 0.01% |
1. Faster titration; 2. Does not contain harmful alcohols; 3. Inhibits side reactions and has no precipitation; 4. Improves accuracy and reproducibility; 5. Unchanged commitment and consistent high quality. |
Titrant for aldehydes and ketones |
1.88006.1000 |
Special type for aldehydes and ketones, can also be used for non - aldehyde and non - ketone products 1ml can titrate 5mgH2O |
|
Solvent for aldehydes and ketones |
1.88007.1000 |
Special solvent for aldehydes and ketones |
Send Inquiry to This Supplier
You May Also Like
-
Multi-parameter Water Quality Analyzer Multi3630NegotiableMOQ: 1 Combo
-
German WTW Portable Conductivity Meter Cond 3310NegotiableMOQ: 1 Combo
-
German WTW Portable Dissolved Oxygen Meter Oxi 3310, Measuring Range 0~90mg/LNegotiableMOQ: 1 Combo
-
German WTW Portable Multi-parameter Water Quality Analyzer Multi 3620NegotiableMOQ: 1 Combo
-
TetraCon 925 Conductivity Electrode, WTW, GermanyNegotiableMOQ: 1 Combo
-
German WTW Dissolved Oxygen Sensor, Product Number 201300, Model FDO 925NegotiableMOQ: 1 Box
-
WTW Multi 3620 IDS Multi-parameter Portable Water Quality AnalyzerNegotiableMOQ: 1 Combo
-
German WTW Online PH Electrode SensoLyt SEA is Resistant to High Temperature and High PressureNegotiableMOQ: 1 Box
-
PhotoLab 7600 UV-VIS UV Spectrophotometer, WTW, GermanyNegotiableMOQ: 1 Combo
-