Home > Instruments & Meters > Analysis Instrument > pH Meter > Double Salt Bridge SZ 245 ORP Electrode for Wastewater Treatment Applications

Double Salt Bridge SZ 245 ORP Electrode for Wastewater Treatment Applications

Double Salt Bridge SZ 245 ORP Electrode for Wastewater Treatment Applications photo-1
Negotiable MOQ: 100 Pieces (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Business Type:
Agent
Year Established:
2015
Main Markets:
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days

As a specialized agent in environmental monitoring solutions since 2015, Shanghai CAMP Environmental Protection Technology proudly introduces our Double Salt Bridge ORP Electrode – engineered specifically for challenging wastewater treatment applications. With extensive experience serving global markets across North America, South America, Europe, Asia and beyond, we understand the critical need for reliable oxidation-reduction potential measurement in industrial water management systems. This electrode represents our commitment to providing robust instrumentation that delivers accurate process control while minimizing maintenance requirements.

Gold/reference combination for SZ 245ORP electrode. Ceramic core junction

Temperature: 0 - 60°C

Pressure: 7 bar

Cable: 9 meters

Dimensions: 110x12 mm

Core Technological Advantages:

  • Enhanced Contamination Resistance – The dual-chamber salt bridge design creates an additional barrier against sulfide and heavy metal poisoning, significantly extending service life in aggressive wastewater environments

  • Stable Reference Potential – Features saturated KCl electrolyte with Ag/AgCl reference system for drift-free measurements even during prolonged operation cycles

  • Rugged Construction – Chemical-resistant glass body withstands pH fluctuations and abrasive media commonly found in aeration tanks and clarifiers

  • Temperature Compensation Ready – Compatible with standard temperature probes for automatic correction across 0-80°C operating range


Operational Benefits for Wastewater Facilities: Municipal and industrial treatment plants achieve superior process control through continuous ORP monitoring during critical stages including anaerobic digestion, chemical oxidation, and disinfection. The electrode's contamination-resistant design reduces calibration frequency by up to 40% compared to single-bridge models, while the replaceable reference electrolyte system cuts long-term ownership costs. Installation flexibility allows deployment in diverse applications:

  • Oxidation Control – Precise chlorine dosing in disinfection stages

  • Reduction Monitoring – Optimization of dechlorination processes

  • Biological Treatment – Aeration control in activated sludge basins

  • Chemical Treatment – Real-time monitoring of cyanide destruction

Backed by Shanghai CAMP's decade-long expertise in environmental instrumentation and supported across 14 global markets, this electrode delivers uncompromised performance where measurement reliability matters most. Our technical support team provides application-specific guidance for integration with existing SCADA systems and process analyzers. Choose a solution engineered for wastewater's harshest conditions – contact us today for configuration options tailored to your plant's specific monitoring requirements.

Frequently Asked Questions:

Q1: How often should the electrolyte be replenished?
A: Under typical wastewater conditions, electrolyte refills are recommended every 2-3 months depending on temperature and contamination levels.

Q2: Is this electrode compatible with standard ORP meters?
A: Yes, it features universal BNC connection and works with most industrial ORP transmitters.

Q3: What makes double salt bridge superior for wastewater?
A: The secondary chamber prevents reference electrode poisoning from sulfides and heavy metals, common in sewage and industrial effluents.

Q4: Can it withstand high-pressure cleaning cycles?
A: The 5-bar pressure rating allows occasional CIP procedures, though prolonged high-pressure exposure should be avoided.

Q5: What maintenance procedures are required?
A: Routine maintenance includes monthly glass bulb cleaning, quarterly electrolyte renewal, and annual junction inspection.

Q6: Do you provide custom cable lengths?
A: Cable extensions from 1m to 20m are available upon request for specific installation needs.

Q7: How should the electrode be stored when not in use?
A: Store vertically in protective cap with storage solution (3M KCl) to prevent dehydration.

Q8: What is the typical lifespan in municipal wastewater?
A: With proper maintenance, expect 12-18 months service life in primary treatment applications.

Product Tags: Double Salt Bridge ORP Electrode , ORP Sensor for Wastewater , Industrial Oxidation-Reduction Electrode

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Platinum Verified Supplier
1Yr
Verified Business License
Business Type
Agent
Year Established
2015
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location
Shanghai, China

Recommended Categories

Explore top categories and find suppliers for your specific needs