Home > Electrical & Electronics > Optical Fiber, Cable & Wire > Electric Wire & Cable > Industrial Self-Regulating Heating Cable 120V, 10W/ft, for Roof & Gutter De-Icing

Industrial Self-Regulating Heating Cable 120V, 10W/ft, for Roof & Gutter De-Icing

Industrial Self-Regulating Heating Cable 120V, 10W/ft, for Roof & Gutter De-Icing photo-1
Industrial Self-Regulating Heating Cable 120V, 10W/ft, for Roof & Gutter De-Icing photo-2
Industrial Self-Regulating Heating Cable 120V, 10W/ft, for Roof & Gutter De-Icing photo-3
Industrial Self-Regulating Heating Cable 120V, 10W/ft, for Roof & Gutter De-Icing photo-4
Industrial Self-Regulating Heating Cable 120V, 10W/ft, for Roof & Gutter De-Icing photo-5
Negotiable MOQ: 100 Meters (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Application:
Other, Roof & Gutter De-icing
Certification:
Other, UL listed
Voltage Rating:
120V
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Application Other, Roof & Gutter De-icing
Certification Other, UL listed
Voltage Rating 120V
Power Output 10W/ft
Heating Technology Self-Regulating
Operating Temperature -40°C to 65°C
Jacket Material Fluoropolymer
Installation Method Cut-to-length

As a specialized manufacturer based in Jinan, Shandong, Shandong Huaning Electric Heating Technology Co.,Ltd delivers reliable industrial-grade heating solutions. Our Self-Regulating Heating Cable (120V, 10W/ft) is engineered to prevent costly ice dams and structural damage in commercial roofing and gutter systems. This advanced cable automatically adjusts heat output based on ambient temperatures, offering precise thermal management while optimizing energy efficiency. Trusted by facility managers across harsh winter climates, it ensures operational continuity and safety.

Core Technical Advantages:

  • Intelligent Self-Regulation: Polymer matrix technology allows the cable to increase/decrease wattage in response to temperature changes without external controls.
  • Energy-Efficient Operation: Draws only necessary power (e.g., higher output during freeze conditions, lower during mild periods), reducing electricity costs by up to 50% vs. constant-wattage cables.
  • Parallel Circuit Design: Enables on-site cutting to exact length requirements without compromising performance or creating hot spots.
  • Robust Fluoropolymer Jacket: Resists UV degradation, chemicals, and moisture penetration for extended outdoor service life.
  • Simple Installation: Compatible with standard clips, tapes, and mounting hardware for gutter downspouts, roof edges, and drain pipes.

Performance Specifications:

Parameter Value
Maximum Continuous Exposure 65°C (149°F)
Minimum Installation Temperature -40°C (-40°F)
Maximum Circuit Length 150 ft (45m) at 120V
Bend Radius (Min) 1 inch (25mm)
Cold-Lead Options Available upon request

Client Benefits: This system prevents ice accumulation that can cause:

  • Roof collapses from excessive weight
  • Gutter detachment due to ice expansion
  • Water infiltration damaging interiors
  • Safety hazards from falling icicles

Backed by Shandong Huaning's decade-long expertise in electric heating technology from Jinan, China, our cables undergo rigorous quality control testing. We support global projects requiring reliable cold-climate infrastructure protection. The UL certification ensures compliance with international electrical safety standards. Contact our engineering team today for custom system designs tailored to your building specifications and regional snowfall data.

Frequently Asked Questions (FAQ):

  1. Q: Can this cable be installed on all roof types?
    A: Yes, it is compatible with asphalt shingles, metal roofing, and PVC membranes when using appropriate mounting accessories.
  2. Q: How does the self-regulating feature save energy?
    A: It automatically reduces wattage when temperatures rise (e.g., during daylight or above-freezing conditions), consuming only essential power.
  3. Q: Is a thermostat required?
    A: While optional for basic operation, pairing with a moisture/temperature controller enhances efficiency further.
  4. Q: What maintenance is needed after installation?
    A: Visual inspections for physical damage before winter season are recommended. No routine servicing is required.
  5. Q: Can it be cut to any length?
    A: Yes, cut points are marked every foot. Minimum length per circuit is 1 ft.
  6. Q: Is the cable safe around standing water?
    A: The fluoropolymer jacket provides IP67 waterproof rating. Suitable for submerged gutter applications.
  7. Q: How long is the product warranty?
    A: Standard 3-year warranty against manufacturing defects. Extended terms optional.
  8. Q: Can it be used on plastic gutters?
    A: Yes, surface temperature remains below plastic deformation thresholds when properly installed.
Product Tags: Self-regulating heating cable , Roof de-icing cable , Gutter heat trace

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!