Home > Electrical & Electronics > Optical Fiber, Cable & Wire > Electric Wire & Cable > Self-Regulating Heating Cable for Commercial and Residential Water Pipes

Self-Regulating Heating Cable for Commercial and Residential Water Pipes

Self-Regulating Heating Cable for Commercial and Residential Water Pipes photo-1
Self-Regulating Heating Cable for Commercial and Residential Water Pipes photo-2
Self-Regulating Heating Cable for Commercial and Residential Water Pipes photo-3
Self-Regulating Heating Cable for Commercial and Residential Water Pipes photo-4
Self-Regulating Heating Cable for Commercial and Residential Water Pipes photo-5
Negotiable MOQ: 100 Meters (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Material:
PTC conductive polymer core + fluoropolymer outer jacket
Voltage:
120V or 240V AC
Temperature Rating:
-40°C to 65°C ambient
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Material PTC conductive polymer core + fluoropolymer outer jacket
Voltage 120V or 240V AC
Temperature Rating -40°C to 65°C ambient
Maximum Exposure Temperature 85°C
Pipe Compatibility Metal and plastic water pipes
Applications Residential & commercial plumbing freeze protection
Installation Type Straight-line or spiral wrap installation
Certifications UL/cUL listed (confirm with manufacturer)
Cutting Length Customizable at job site (min. 0.3m)
Thermal Output 10W/m to 30W/m (temperature-dependent)

Shandong Huaning Electric Heating Technology Co., Ltd., a trusted manufacturer based in Jinan, China, presents its advanced Self-Regulating Heating Cable solution engineered for reliable freeze protection in both residential and commercial water pipes. Our innovative heating technology automatically adjusts heat output based on ambient conditions, providing precise temperature maintenance while minimizing energy consumption. Designed to prevent costly pipe bursts during freezing weather, this system offers hassle-free installation and maintenance-free operation for critical plumbing infrastructure.

Core Technology & Operation Principle:
The cable features a conductive polymer core that naturally increases electrical resistance as temperatures rise. This intrinsic self-regulating property means:

  • Automatic heat reduction in warmer areas (preventing overheating)
  • Increased heat output where temperatures drop below freezing
  • No external thermostats required for most applications
  • Energy savings of 15-30% compared to constant-wattage cables

Technical Specifications & Performance Data:

Parameter Value
Power Output at 10°C 20W/m (standard model)
Startup Current (per meter) < 0.5A
Minimum Bending Radius 25mm
Jacket Material Fluoropolymer (chemical/corrosion resistant)
Thermal Cycling Capability 10,000+ cycles

Installation Advantages:

  • Field-cuttable design allows customization to exact pipe lengths
  • Compatible with all common pipe materials including PVC, copper and steel
  • Simple attachment with aluminum tape or cable ties
  • Maintains effectiveness even when overlapped (no hot spots)

Application-Specific Solutions:
Our cables are specified for diverse scenarios including:

  • Residential: Exterior wall pipes, crawl spaces, attics
  • Commercial: Fire sprinkler systems, rooftop plumbing, parking garage lines
  • Industrial: Process water lines, outdoor tanks, valve protection

Backed by Shandong Huaning's decade of specialized experience in electric heating technologies, this product undergoes rigorous quality control at our Jinan manufacturing facility. Our engineering team provides technical support for system design and installation best practices. For critical infrastructure protection in temperatures as low as -40°C, this reliable solution delivers:

  • Reduced risk of property damage from frozen pipes
  • Lower insurance premiums through risk mitigation
  • Compliance with building codes in cold climates
  • 5-year limited warranty (terms apply)

FAQ Section:

Q1: Can this cable be used on plastic pipes?
A: Yes, the self-regulating technology prevents overheating, making it safe for PVC, CPVC and PEX pipes when properly installed.

Q2: How is power consumption calculated?
A: Consumption varies with temperature. At 0°C, standard cable uses approx. 20W/m. Actual usage depends on insulation quality and temperature differential.

Q3: Does it require professional installation?
A: While DIY installation is possible for simple runs, we recommend professional installation for complex systems and commercial applications.

Q4: What maintenance is needed?
A: The system is maintenance-free once installed. Periodic visual inspection of connections is recommended.

Q5: Can it be used in explosive environments?
A: Standard models are not explosion-proof. Consult us for hazardous location certifications.

Q6: How long does the cable last?
A: Typical service life exceeds 15 years when properly installed and not subjected to mechanical damage.

Q7: Is grounding required?
A: All commercial installations require grounding per electrical codes. Our cables include a grounding braid for this purpose.

Q8: Can it be installed on existing pipes?
A: Yes, retrofit installation is common. Ensure pipes are clean and dry before application.

Product Tags: Self-regulating heating cable , Pipe freeze protection system , Water pipe heating tape

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!