KG24ZCD24C-500A CAN-Freesor-current Sensor New Energy Current Sensors
|
24Vsinglepowersupply Ratedcurrentmeasurement range±500A Workingtemperature range:-40°C∽+85°C Outputsignal:High speedCAN(500kbps) Acombinederrorof 0.5%overthetemperaturerange Thecombinederror of0.3%atroomtemperature25℃ Primarysecondarysideisolation measurement Connectortype:TE/AMP1473672-1 |
Current measurementforbatterymanagementsystems (SOC,SOH,SOF,etc.) |
parameter |
symbol |
unit |
value |
Testcondition |
|
Impulsevoltage |
Vc |
V |
32 |
400ms |
|
Overvoltage |
Vc |
V |
26.7 |
1min |
|
Negativepressure resistance |
Vc |
V |
-30 |
1min |
|
Creepagedistance |
dcp |
mm |
7.2 |
|
|
Electricalclearance |
dci |
mm |
6.95 |
|
parameter |
symbol |
unit |
Minimum value |
Typical value |
Maximum value |
Testcondition |
|
Ratedinputcurrent |
Ipn |
A |
-500 |
- |
500 |
- |
|
Measuringcurrent range |
Ipm |
A |
-530 |
- |
530 |
- |
Supplyvoltage |
Vc |
V |
22.8 |
24 |
25.2 |
- |
|
Powersupply consumptioncurrent |
Ic |
mA |
- |
35 |
50 |
@25℃,Vc=24V,IP=0A |
|
Powersupply consumptioncurrent |
Ic |
mA |
- |
65 |
80 |
@25℃,Vc=24V,IP=500A |
|
Linearityerror |
ε |
%FS |
-0.1 |
- |
0.1 |
@25℃ |
|
Noisecurrent |
Ioe |
mA |
-10 |
10 |
@Ip=0,TA=25℃ |
|
|
Temperaturedrift |
TC |
ppm/℃ |
70 |
TA=-40~85℃ |
||
Send Inquiry to This Supplier
You May Also Like
-
FS1000F Freesor-current SensorUS$ 10MOQ: 96 Units
-
FS500ATS Freesor-current SensorUS$ 18.6MOQ: 96 Units
-
FS2500AX Freesor-current SensorUS$ 18MOQ: 36 Units
-
FS5000KA Freesor-current SensorUS$ 33MOQ: 20 Units
-
FSM500LTB Freesor-current SensorUS$ 19.5MOQ: 96 Units
-
FSM1005LFS Freesor-current SensorUS$ 60MOQ: 24 Units
-
FSM2005LF Freesor-current SensorUS$ 95MOQ: 12 Units
-
FSM3005US$ 263MOQ: 5 Units
-
FSM4005 Freesor-current SensorUS$ 800MOQ: 1 Unit
-
FSM500LCF-Freesor-current SensorUS$ 72MOQ: 50 Units