Home > Electrical & Electronics > Relay & Contactor > Relay > Emerson KJ1501X1-BB1 DeltaV System Power Module – Stable Backplane Power for DeltaV M‑series Nodes

Emerson KJ1501X1-BB1 DeltaV System Power Module – Stable Backplane Power for DeltaV M‑series Nodes

Emerson KJ1501X1-BB1 DeltaV System Power Module – Stable Backplane Power for DeltaV M‑series Nodes photo-1
US$ 2216.00 ≥1 Blade
Key Specifications
Get Latest Price
I/O Number:
KJ1501X1-BB1
Place of Origin:
America
Communication Interface:
Modubus
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
I/O Number KJ1501X1-BB1
Place of Origin America
Communication Interface Modubus
Model Number Emerson KJ1501X1-BB1
Condition NEW
Warranty One Year
Package Original Packaging
HS Code 850440
Company’s Order Placement Process and Guarantees
  • Warranty: 365 days

  • Lead time: 1 week if in stock; no more than 1 month at the latest

  • Payment: 50% advance payment; full payment prior to delivery

  • Express options: FedEx, UPS, DHL

Key Features
  • Designed for DeltaV M‑series carriers – Plugs directly into standard M‑series horizontal or vertical carriers; no special adapters.

  • 24 VDC system distribution – Feeds regulated 24 VDC to the backplane to power controllers and I/O, keeping field hardware isolated from bulk supply variations.

  • Redundancy-ready – In many cases you can fit two power modules on the same carrier for automatic failover; replacement of one unit is typically possible without process interruption.

  • Front-panel status LEDs – Quick at-a-glance health and fault indication; useful when you’re troubleshooting in a crowded cabinet.

  • Robust mechanical design – Positive latching and keyed mechanical alignment help avoid mis-insertion and vibration issues over long service cycles.

  • Low-touch upkeep – No configuration software; just reliable backplane power with routine visual checks.

Technical Specifications
Brand / Model Emerson DeltaV / KJ1501X1-BB1 (System Power Module)
HS Code 8504.40 (Static converters – power supplies)
Power Requirements 24 VDC nominal input from external bulk supply; distributes 24 VDC onto the DeltaV backplane
Signal I/O Types Power distribution only (no analog/digital signal channels)
Communication Interfaces None (front status LEDs for diagnostics)
Installation Method Plug-in module for DeltaV M‑series carriers; supports redundant pairing where carrier supports dual supplies
Application Fields

This module is typically specified anywhere a DeltaV M‑series node is installed: refining and petrochemicals, specialty chemicals, power generation (including CCGT and CHP), pharmaceuticals, food & beverage, and water/wastewater. A maintenance lead at a mid‑size chemical plant summed it up well: “Once we paired the KJ1501X1 modules for redundancy, power alarms practically disappeared during switchovers.”

D1F2A77952A7729F5FB225D562FE4249

Advantages & Value
  • Reliability you can plan around – Stable 24 VDC backplane power reduces nuisance trips and intermittent faults tied to marginal supplies.

  • Compatibility baked in – Purpose-built for DeltaV M‑series carriers; no third-party adapters or rewiring tricks.

  • Redundancy without complexity – In many cases, two modules share load and provide seamless failover; that translates to fewer planned outages.

  • Lower lifecycle cost – Minimal maintenance, quick replacement, and long service life help trim OPEX over the system’s lifecycle.

  • Practical support – Straightforward diagnostics and established install practices speed up commissioning and troubleshooting.

Installation & Maintenance
  • Cabinet standards – Install in a clean, dry, ventilated control cabinet; follow DeltaV M‑series carrier spacing and mounting guidelines.

  • Power wiring – Supply from a regulated 24 VDC bulk source sized for full node load plus redundancy margin; use correctly rated conductors and protective devices.

  • Ventilation – Provide airflow to avoid heat buildup around the carrier; avoid bundling power with high-noise cabling.

  • Safety – De-energize the bulk 24 VDC feed before first installation; with redundant pairs, one unit can typically be replaced online, but follow site MOC and LOTO procedures.

  • Routine checks – Periodically inspect terminal tightness, look for discoloration or dust buildup, and verify status LEDs during PM rounds. Firmware updates are not applicable to this power module.

Quality & Certifications
  • Conformity: CE

  • Safety: UL recognized (typical for DeltaV M‑series modules)

  • Environmental: RoHS compliant

  • Manufacturing Quality: Produced under ISO 9001 quality systems

  • Warranty: 365 days

Product Tags: Emerson KJ1501X1-BB1 , KJ1501X1-BB1

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Trading Company
Year Established
2014
Annual Export Value
US$2.5 Million - US$5 Million
Total Employees
51 - 100 People