PH Detection Pen Water Quality Testing

PH Detection Pen Water Quality Testing photo-1
PH Detection Pen Water Quality Testing photo-2
PH Detection Pen Water Quality Testing photo-3
PH Detection Pen Water Quality Testing photo-4
PH Detection Pen Water Quality Testing photo-5
US$ 1.6 - 2 MOQ: 100 Pieces
Key Specifications
Get Latest Price
Business Type:
Trading Company
Annual Export Value:
US$1 Million - US$1.5 Million
Total Employees:
5 - 10 People
Payment & Shipping
Payment Methods:
Port of Shipment:
SHANGHAI
Delivery Detail:
5 days


PH detection pen

Model: PH-02

Display mode: digital display

Probe type: Glass probe

Color: Yellow/Blue

Test range: 0.1-14PH

Resolution: 0.01PH

Error: ± 0.1PH

Battery: 2 * 1.5V (LR44)

Temperature compensation: 0-50 ℃

Operating temperature: 0-80 ℃

Size: 155 * 31 * 18mm

Net weight: 50g

characteristic:

Accurate detection, large screen display, temperature compensation, CE certification, simple operation, easy to carry

Usage steps:

Step 1: Remove the protective cover, clean the electrode of the pH meter with distilled water, and use filter paper to absorb the moisture attached to and around the electrode.

Step 2: Tap "ON/OFF" to turn on the power, insert the instrument into the tested solution, immerse the tested electrode in the solution, gently shake the instrument to drive away bubbles, wait for the value to stabilize, read the displayed number, and after use, press "ON/OFF" to turn off the power, wash the electrode with clean water, and put on a protective cover.

-------------------------------------------------------------------------------------------------------------


Calibration steps:

1: Pour 6.86, 4.00, and 9.18 standard buffered saline and distilled water into different clean cups.

2: For precise calibration, each buffer solution is divided into two cups. One cup is filled with clean water to rinse the electrodes, and the other solution is used for calibration.

3: Tap the 'power button' to turn on the power.

4: Place the electrode in a pH 6.86 standard solution and gently shake until the value stabilizes.

5: Press and release the "CAL" button for about 5 seconds, and the instrument will enter automatic calibration mode until the displayed value is consistent with the pH value of the standard buffer solution at that temperature, completing the pH 6.86 point calibration.

6: Clean the electrode and wipe it dry. Place the electrode in a pH 4.00 standard buffer solution and gently shake until the value stabilizes.

7: The measurement methods for PH4.00 and PH9.18 are different from the standard buffer solvent for measuring PH6.86,


Reminder

1: After five minutes of inactivity, the instrument panel automatically shuts down, extending the battery life,

2: The height of the pen tip immersed in the solution should be less than 4CM to avoid affecting accurate readings.


Product Tags: PH , Water quality testing , water quality , detection

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
2Yrs
Business Type
Trading Company
Annual Export Value
US$1 Million - US$1.5 Million
Total Employees
5 - 10 People
Port of Shipment
Qingdao, Dalian, Ningbo, Shanghai

Recommended Categories

Explore top categories and find suppliers for your specific needs