Home > Electrical & Electronics > Passive Components > Capacitor > Acrel 1 DC Voltage Signal is Isolated and Outputs 1 DC DC0/1-5V or 0/2-10V Signal Isolated Safety Barrier, BM200-DV/V-B11

Acrel 1 DC Voltage Signal is Isolated and Outputs 1 DC DC0/1-5V or 0/2-10V Signal Isolated Safety Barrier, BM200-DV/V-B11

Acrel 1 DC Voltage Signal is Isolated and Outputs 1 DC DC0/1-5V or 0/2-10V Signal Isolated Safety Barrier, BM200-DV/V-B11 photo-1
Acrel 1 DC Voltage Signal is Isolated and Outputs 1 DC DC0/1-5V or 0/2-10V Signal Isolated Safety Barrier, BM200-DV/V-B11 photo-2
Acrel 1 DC Voltage Signal is Isolated and Outputs 1 DC DC0/1-5V or 0/2-10V Signal Isolated Safety Barrier, BM200-DV/V-B11 photo-3
Acrel 1 DC Voltage Signal is Isolated and Outputs 1 DC DC0/1-5V or 0/2-10V Signal Isolated Safety Barrier, BM200-DV/V-B11 photo-4
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Business Type:
Manufacturer
Year Established:
2003
Factory Size:
3,000-5,000 square meters
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.

BM200 isolated safety barrier can transmit signals between the safe area and the dangerous area, and limit the energy transfer from the safe area to the dangerous area caused by the fault. The voltage, current, temperature, resistance signals generated by the equipment (transmitter) on the dangerous side are isolated and converted into corresponding linear voltage and current signals outputting to the safe area. The product requires independent power supply, and the input/output/power supply is isolated. It can be used in current source, two-wire, three-wire transmitter equipment. 

① DC voltage/current input

② Using magnetic isolation technology

③ Response time <400ms

④ TS35 rail installation

⑤ Plug-in terminal

⑥ Temperature drift coefficient: ≤200ppm/℃ at 0.5 level

Technical Parameter
Channel type
Single-way input and single-way output,
single-way input and double-way output,
double-way input and double-way output
Input type
Current/Voltage/Thermal resistance Pt100/Resistance/Thermocouple
Input signal
0~20mA /4~20mA
0~5V /0~10V /1~5V (Distribution voltage: 12V/20mA)
PT100 /0~10K/K、E、T、J、N、R、S、B
Output signal
0~20mA /4~20mA (Safe side input); Load resistance: ≤550Ω
0~5V /1~5V (Safe side input); Load resistance: ≥330K
0~10V (Safe side input); Load resistance: ≥500K
Transmission accuracy
0.20%
Temperature modulus
50ppm/℃ (The output signal is current)
Response time
5ms to reach 90% of final value
(RTD Pt100/resistance/thermocouple input: 1s to reach 90% of final value)
Power supply
20~35V DC
Work temperature
-20℃~+60℃
Fix mode
Rail installation
Dielectric strength
Intrinsically Safe and Non-Intrinsically Safe ≥2500V AC; Power supply and
Non-Intrinsically Safe ≥500V AC
Note:Intrinsically Safe is input, Non-Intrinsically is output
Dimension
Wiring
Solution Structure
Application
Payment & Delivery
Company Profile


Product Tags: Voltage input isolation safety barrier , Current input isolation safety barrier , Potentiometer Input Isolated Safety Barrier

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2003
Factory Size
3,000-5,000 square meters
Annual Export Value
US$10 Million - US$50 Million

Recommended Categories

Explore top categories and find suppliers for your specific needs