
- Zhuhai City Snova Technology Co., LTD
- Main products: Earth Fault Indicator, Cable Fault Indicator, Overhead Line Ground Fault Indicator, Short Circuit and Earth Fault Indicator, Cable Temperature and Faults Sensor, Industrial Dehumidifier, Temperature and Humidity Controller, Fault Passage Indicator, Remote communication terminal, Smart grid system
Home > Products > Overhead Line Fault Indicator > what is fault indicator
what is fault indicator
- 5000 Set / Sets per Month
- Shenzhen
- T/T D/P D/A Other
- 7 days
You May Like
-
GSM and GPRS/GPS remote Communication Terminal system,IEC101
-
China factory supplier Power Accessories
-
Overhead Line fault indicator for Generator, Transformer, Cables, Loads
-
RTU for earth fault indicator
-
Remote Wireless Communication Terminal for overhead grounding and short circuit fault
-
Remote Wireless Communication Terminal for overhead grounding and short circuit fault
Product Details
Brand Name | SNOVA | Place of Origin | China | |
Model Number | SNV-308.1 |
Product Description
what is fault indicator
Description
SNV Indicators suitable for overhead lines with a 50KV below four remotes short circuit &Earth fault indicator, through measuring the current of a cable, to judge the fault on the power lines according to the change of current, grounding fault, and the fault state, real time current, battery voltage and other information is uploaded to the remote server, which provides reliable data for the various types of fault diagnosis and location of overhead lines
Character:
l real-time sampling of current per cycle;
l ultra low power real-time sampling;
* When line current value≧5A,CT can supply meet the indicator power requirement
*Sampling accuracy5-20A±1.5A,20-800A±3%
l Sensor factory automatic calibration, to ensure consistency;
l intelligent motor control flop;
l Support remote, telemetry, remote control, remote adjust;
Function character
a. real time measurement of three-phase on line current;
b. Detection and judgment of short circuit fault;
a) | support the determination of the set threshold, fault current, short circuit fault; |
b) | supports the determination of a set of mutated incremental currents for short-circuit faults; |
c) | supports the determination of the percentage of short circuit faults that can be set by the percentage of mutated currents; |
d) | support for reclosing identification; |
c. Detection and judgment of ground fault
d. Data Upload function;
a) | periodically upload real-time online current, zero sequence current, and battery voltage; |
b) | Upload the fault status, the fault elimination status and the fault current value in real time; |
e. Parameter setting
a) Available to change the parameter setting through Web server. |
b) Available to change and set the parameter though remote setting control PDA; |
c) Support RS232 port for parameter modification and maintenance |
f. Support setting controller (PDA)
a) | Available reading and change setting parameter; |
b) | PDA can read Indicator sensor state , Real time line current, battery voltage data. |
c) | PDA can simulate the online fault test through setting Indicator’s parameter. |
g. Intelligent motor control flop to red flag;
h. Six three-color fault indicating led;(red, green, blue)
i. One yellow state led light;
j. Support line CT power charge for battery;
k. Support timing reset, power on auto reset, remote reset;
l. can be efficiently mounted and unloaded;
m. The structure parts are made of antirust and anticorrosion material;
n. In waking up state(wireless setting model),During 7 minutes, without operate, there will be auto reset.(Tips: in waking up state, FI prohibited fault test)
Function display
Flag state
1) Normally, Flag is on blanket position. Every 3hour, Flag will reset one times for avoiding un fault turn to red flag. |
2) When short circuit fault happen, it will turn to red flag state; After reach reset time or when the line current restore, Fault indicator will turn back to blanket state; |
3) when the earth fault happen, it will turn to red flag state. It will be automatically turn back blanket state when line power off and current restore, or wait until reach reset time. |
Fault indicating Led light:
1) short circuit permanent fault indicating: Six 3-color led will shine red color, and four times, every 2 second,And turn to red flag at same time。 |
2) short circuit temporary fault indicating: Six 3-color led will shine green color, and four times, every 2 second,And turn to red flag at same time。 |
3) Earth Fault indicating:Six 3-color led will shine Blue color, and four times, every 2 second. And turn to red flag at same time. |
yellow state Led light:
Battery voltage too low: | Shine 1 time, every2second |
Battery voltage low: | shine 2 time, evey2second |
Wireless setting state: | shine 4 times, every 2 second |
Contact Us
- Zhuhai City Snova Technology Co., LTD
- Contact nameAndrewmao Chat Now
- Phone86-13570657698-8621065
- AddressXiangzhou district, Zhuhai, Guangdong
Product Categories
New Products
-
Underground indicators Earth fault indicator for smart grid SNV-EFI
-
Underground cables fault locator with big battery capacity 19000mHA EFIV2.0
-
Surface Mounted Type SNV-EFI Earth Fault Indicator
-
Grounding and short circuit fault indicator adjust alarm current by DIP
-
Hot Sell for DIstribution Network ,current power fault location SNV-EKL3.2
-
Underground indicators Earth fault indicator for smart grid SNV-EFI
-
SNV-EKL3.2 Earth fault and short circuit indicator
-
SNV-EKL4 V2.1 Earth Fault Indicator for MV Power Distribution Network
-
SNV-EFI Earth Fault Indicator
-
Control PDA for Fault Locator In Transmission Lines
-
Grounding Faul Indicator earth fault indicator
-
Electric Handcart and Ground Knife Integrated Protector
-
fault locator of Power distribution equipment
-
SNV-EKL4 V2.1 Earth Fault Indicator cable sensor
-
Grounding Fault Sensor and Current Short Circuit Indicator
-
12 Meters Hotstick Installation adapter of Overhead Line Fault Indicator
-
12 Meters Hotstick Installation adapter of Overhead Line Fault Indicator
-
SNV-EKL4 V2.1 short circuit fault sensor for distribution network
-
Industrial intelligent dehumidifier for distribution cabinet
-
Simulated Failure Remote Controller for Overhead Line Fault Indicator
-
Medium-voltage Distribution System Short-circuit and Ground Fault Device
-
How to install Cable type earth fault and short circuit indicator EKL4
-
How to install Cable type earth fault and short circuit indicator EKL4
-
Cable short circuit and grounding fault indicator SNV-EKL3.2
Popular Searches
- cable accessories
- Monitoring System
- fiber laser source
- inductor
- overhead
- ring main unit switchgear
- overhead cable
- cable fittings
- tools kit
- fault detector
- position indicator
- alarming apparatus
- electrical inductor
- short circuit indicator
- earth fault
- powerful system
- earth fault indicator
- short circuit fault indicator
Recommended Products
- Wholesales NSPV MLJ-01 connector Solar PV Panel Mini Junction Box
- 17.5 KV Full-enclosed Outdoor Epoxy Resin Casting and Double Pole Insulated Voltage Transformer
- JDZX10-10 Single Phase Indoor Fully Insulated Resin Integrated MV&HV Transformer 10kv High Voltage JDZ10-10A/B
- JDZ10 Sheep Angle Enclosed 10kV Indoor High-voltage Transformer
- JDZ10-10A B BE Indoor High-voltage Fully Enclosed Type Voltage Transfommer
- 33Kv Voltage Transformer Power Transformer 110V 220V Voltage Converter 10Kw High Voltage Transformer 15Kv
- Factory Directly Sells JDCF Single Phase Outdoor High Voltage Potential Transformer 110KV Oil Filled PT
- JSZV12-10R 2025 Fuse Voltage Transformer High Performance Transformers Product Genre
- JSZV12-10R Type High Voltage Voltage Transformer 10KV Indoor Dry Three-phase Built-in Fuse
- Chinese Supplier Step Down Cast Resin Dry Type Intermediate Frequency Transformer
- Transformer 75KVA 7.2KV/0.12KV Factory Price Energy-saving Oil-type Single-phase Transformer for Sale
- JLSZY-10 Outdoor Single-Phase Three-Wire High Voltage Measuring Box 10KV Dry Combined Transformer for Power Use
Find Similar Products By Category
- Electrical & Electronics > Power Supply & Distribution > Power Distribution Cabinet & Box
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andrewmao
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile