- Acrel Electric Co., Ltd
- China Manufacturer with main products:Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement
Home > Products > AM Series Protection Relay > Acrel start control motor protector AM5SE-MD application high power asynchronou 4-20mA analog output remote control GPS FC block
Acrel start control motor protector AM5SE-MD application high power asynchronou 4-20mA analog output remote control GPS FC block
- 100 Piece / Pieces per Month
- T/T
- Acrel RS485 motor protector AM5SE-D3 application main power transformer protection three winding main power transformer r
- Acrel motor protection relay AM5SE-K application public measurement and control device remote measurement
- Acrel WHD20R-11/C with RS485 communication 35mm DIN Mount Intelligent temperature and humidity controller High precision
- Acrel WHD20R-22/J with alarm Intelligent temperature and humidity controller measure two channel temperature&humidity 35mm DIN Mount
- Acrel WHD46-22/C with RS485 communication Intelligent temperature and humidity controller Used in high and medium voltage switch cabinet, ring network cabinet, terminal box, etc
- Acrel WHD72-22/M with two analog output measure two channel temperature&humidity with sensors Intelligent temperature and humidity controller
Product Description
AM5 series microcomputer protection device are applicable to the user substation which the input voltage is 35kv or above. AM5 can be used to protect and control the user substation, and is be widely used to Power Industry, Water conservancy industry, Traffic Industry, Oil industry, Chemical industry,Coal Industry, Metallurgical Industry and so on.
AM5SE-F | Directional overcurrent, overcurrent IDMT, earth fault, earth fault IDMT, overload, trip and close circuit supervision, loss of voltage, PT supervision, three phase auto-reclose, under frequency, over frequency, Post-Accelerated overcurrent, overvoltage, residual overvoltage, directional power, FC block, RS485 (2 ports), modbus serial, IEC 60870-5-103,IEC 60870-5-101, 4-20mA analog output SOE, electric parameter (U,I, P, Q,PF, F, Ep, Eq, Es), remote control, GPS.fault recoeder numbers of circuit breaker trip and close trip and close circuit supervision | Line/Feeder |
AM5SE-M | Motor start overcurrent, motor run overcurrent, overcurrent IDMT.earth fault, overload, trip and close circuit supervision,undervoltage,overvoltage, residual overvoltage, PT supervision.non-electricity, blocking rotor, starting time-out, thermal overloadovervoltage average, incorrect phase sequence, voltage phaseloss protection, negative sequence overcurrent, FC blockRS485(2 ports), ethernet (2 ports), USB (1 port), modbus serial,modbus over ethernetIEC 60870-5-103,TCPIEC 60870-5-103IEC 60870-5-101,4-20mA analog output, electric parameter (U1 P Q, PF, F Ep, Eq, Es), fault recorder, numbers of circuitbreaker trip and close, SOE, trip and close circuit supervision.remote control, GPS. | Motor |
AM5SE-B | Directional overcurrent, overcurrent IDMT, bus Charging, trip andclose circuit supervision, PT supervision, bus tie protection andstandby power automatic switch, RS485 (2 ports), ethernet (2ports), USB(1 port), modbus serial, modbus over ethernet, IEC60870-5-103TCPIEC60870-5-103IEC60870-5-1014-20manalog output, electric parameter (U,I, PQ PF, F, Ep, Eq, Es).fault recorder, numbers of circuit breaker trip and close, SOE, tripand close circuit supervision, remote control, GPS | Bus tie |
AM5SE-C | Directional overcurrent, overcurrent IDMT, earth fault, trip andclose circuit supervision, overvoltage, capacitor undervoltage,residual overvoltage, unbalance voltage, unbalance current, PTsupervision,Post-Accelerated overcurrent, non-electricity, RS485(2 ports) Ethernet (2 ports), USB (1 port), modbus serial.modbus over ethernet,EC 60870-5-103,TCPIEC 60870-5-103IEC 60870-5-101,4-20mA analog output, electric parameter (U1, P Q, PF F, Ep, Eq, Es), fault recorder, numbers of circuitbreaker trip and close, SOE, trip and close circuit supervision.remote control,GPS Capacitor | Capacitor |
AM5SE-T | Overcurrent, overcurrent IDMT,earth fault, overload, trip andclose circuit supervision, PT supervision, non-electricity, FC blockRS485 (2 ports), ethernet (2 ports), USB (1 port), modbus serial.modbus over ethernet,IEC 60870-5-103TCPIEC 60870-5-103IEC 60870-5-101,4-20mA analog output, electric parameter (U,P,Q, PF, F, Ep, Eq, Es), fault recorder, numbers of circuit breakertrip and close, SOE, trip and close circuit supervision, remotecontrol, GPS | Transformer |
AM5SE-UB | Undervoltage alarm, PT supervision overvoltage, residual overvoltage, RS485 (2 ports), modbus serial, IEC 60870-5-103, IEC 60870-5-101, tripping context records, SOE, electric parameter (U,I, P, Q,PF, F, Ep, Eq, Es), remote control, GPS. | PT |
AM5SE-D2 | Differontiai protection wih ratio rostraining, instantaneous .bory usn totion. cT aupervion, nens portb) et necet (2Dorts), USB (1 port), modbus serial, modbus ovar athernG0870-5-103. TCPIEC 60870 5103 EC 608705-101,4-20m/analog oulpul, eloctric paramotr (U. 1 P O. P,F,Ep,Eq, Es), faulrocorder, numbors of circult brooker trip and ciose, SOE, trip andclose circult supervision, remote control,GPS | Transformer |
AM5SE-D3 | Three-winding main power transformer quick-break differentialProtection,Percentage biased differential protection. | main power transformer protection |
AM5SE-MD | Differential protection with ratio restraining, instantaneousdifferential protection, motor start overcurrent, motor runovercurrent, overcurrent IDMT, earth fault, overload, trip and closecircuit supervision, undervoltage, overvoltage, residual overvoltageunbalance voltage. unbalance current, PT supervision, CTsupervision, non-electricity, blocking rotor, starting time-out, thermaloverload, overvoltage average, incorrect phase sequence, voltagephase loss protection, negative sequence overcurrent. FC blockRS485 (2 ports), ethernet (2 ports), USB (1 port), modbus serial.modbus over ethernet,IEC 60870-5-103.TCPIEC 60870-5-103IEC 60870-5-101,4-20mA analog output, electric parameter (UIPQ, PF, F Ep, Eq, Es), fault recorder, numbers of circuit breaker tripand close, SOE trip and close circuit supervision, remote control.GPS. | high power asynchronous motor |
AM5SE-K | 20 channels of remote signals, 10 channels of switch outputremote measurement | public measurement and control device |
AM5SE-TB | Undervoltage alarm, PT supervision, overvoltage, RS485 (2 ports), modbus serial, IEC 60870-5-103,IEC 60870-5-101, tripping context records, SOE, electric parameter (U, I, P,Q,PF, F, Ep, Eq, Es), remote control, GPS. | PT |
Contact Us
- Acrel Electric Co., Ltd
- Contact nameShelly Zhang
- Phone86-21-18702111813
- Acrel WHD20R-11/J with alarm 35mm DIN Mount Intelligent temperature and humidity controller High precision
- Acrel WHD48-11/C with RS485communication digital temperature and humidity controller High precision and wide measuring range
- Acrel WHD72-22/J with alarm measure two channel temperature&humidity with sensors Intelligent temperature and humidity controller
- Acrel WHD72-22/C with RS485 communication measure two channel temperature&humidity with sensors Intelligent temperature and humidity controller
- Acrel analog signal isolator BM-AI/IS input AC0-1/5A output DC4-20mA powered by output
- Acrel current isolator BM-DIS/I input DC4-20mA output 4-20mA powered by input
- Acrel input DC0-5/0-10V output 4-20mA power DC24V current isolator BM-DV/I
- Acrel input PT100 output 4-20mA powered by output analog signal isolator BM-AI/IS
- Acrel DC Multi-function Energy Meter PZ72-DE Accuracy 0.5% Power Supply 85~265V AC/DC Communication RS485
- Multi Function 1-circuit DC kWh Rated Voltage 1000V DC Rated Current 10A DC 4 Tariff Rates LCD Display kwh Meter Digital
- PZ72L-DE Paired With Hall Sensor 10A DC Direct Connect PZ Series DC Power Analyzer Rated Voltage 1000V DCW
- Multi-function Power Meter PZ72L-DE Direct Current 4 Tariff Rates Power Supply 85~265V AC/DC PZ Series DC Power Analyzer
- Power Monitoring Controlling Power Monitoring Controlling 4 Tariff Rates CE Certificates Rated Voltage 1000V DC PZ72-DE
- Acrel input DC4-20mA output 4-20mA powered by DC24V analog signal isolator BM-DI/I
- Acrel analog signal isolator BM-DI/V input DC0-20/4-20mA output 0-5/0-10V power 24V
- Acrel current isolator BM-DI/IS input DC 0-1/0-20/4-20mA output 4-20mA powered by output
- ADW310-D16/4GHW IoT One Phase Wireless Smart Energy Meter 20(100)A AC via paired CT iot Smart Meter For House
- ADW310-D16/4GHW IoT One Phase Wireless Smart Power Meter 220~264V Wireless 4G-LTE Communication IOT 20(100)A AC
- Acrel 1Phase Multi Function Communication 20(100)A AC 1-phase Active Reactive Energy Active Pulse Output RS485 ADW310-D16/4GHW
- ADW310-D16/4GHW IoT One Phase Wireless Smart Power Meter 220~264V 2-way Cable Temperature Measurement Application in Building
- ADW310 IoT Single Phase Wireless Smart Energy Meter 20(100)A AC Current RS485 iot Based Electricity Energy Meter House Factory
- Acrel ADF400L-2S din rail Multi Circuit Electrical Instruments 2 channel 3 phase 3*10(80)A High installation flexibility
- Acrel din rail ADF400L-6D Multi Circuit Electrical Instruments 6 channel single phase 10(80)A High installation flexibility
- Acrel din rail ADF400L-6H Multi Circuit Electrical Instruments 6 channel three phase 3*1(6)A High installation flexibility
Popular Searches
Find Similar Products By Category
- Electrical Equipment & Supplies > Relays
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shelly Zhang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-