- Acrel Electric Co., Ltd
-
China Manufacturer with main products:Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement
Home > Products > AMC Series Data Center Monitor Module > Acrel 2 Way Incoming Lines AC Din Rail Multi Circuit Energy Meter AMC16Z-ZA For IDC Data Center Monitoring Power Distribution Monitoring Solution
Acrel 2 Way Incoming Lines AC Din Rail Multi Circuit Energy Meter AMC16Z-ZA For IDC Data Center Monitoring Power Distribution Monitoring Solution
- 1 Kilogram / Kilograms per Month
- T/T L/C Credit Card PayPal
- Acrel Multi Channel Din Rail AC Power Meter AMC16Z-ZA For Data Center Two Channel Incoming Line Monitoring 3 Phase Energy Meter With 485 Interface
- Acrel AMC100-ZA Multi channel din rail ac energy meter 8DI/4DO used in Data center etc
- AMC16Z-ZA RS485 Modbus-RTU 1(6)A AC Via CTs Dual-Circuit 3-Phase Energy Meter 2nd-63rd Harmonic Monitor for Data Center
- Acrel AMC100-ZD DC multi channels din rail energy meter 1channel temperature and humidity monitoring
- Acrel AMC100-FA30 panel AC energy monitoring device measure 30 channels AC outlet all electrical parameters
- Acrel AMC100-FA48 AC multi circuit energy meter measure 48 channels AC outlet all electrical parameters
Product Details
Brand Name: | Acrel | Place of Origin: | China | Model Number: | AMC16Z-ZA |
Operating Temperature: | -20℃~+55℃ | Dimensions: | 180*94.3*45mm |
Packaging Details
It is packed in a crash bag and then put into a cardboard box.
Product Description
AMC16Z-ZA Dual-circuit Data Center Energy Meter
● Monitoring: Dual Independent AC Incoming Circuits 3-phase (For Data Center)
● Measurement: Voltage, Current, Frequency, Active Power, Reactive Power, Power Factor and etc
● Power Quality: 2nd~63rd&Total Harmonic, Current&Voltage Unbalance and etc
● Communicaiton: RS485 (MODBUS-RTU)
● Rated Voltage: 220~264Vac L-N
● Rated Current: 1(6)A AC (via CTs)
● Standard&Certificate: CE; IEC; LVD
● Full Electrical Parameters Monitoring
● Power Quality Analyzing
● 2-channel DO (digital output)
● Temperature&Humidity Monitoring
● Leakage Current Monitoring
1. Function Overview
Function | Description |
Measurement(Common) | Three-phase AC kWh, kVarh, Active Power, Reactive Power, Current, Voltage, Power Factor, Apparant Power, Frequency, Zero ground voltage, neutral line current |
Measurement(Power Quality) | total harmonic content (THD), 2-63 harmonics, current and voltage unbalance degree, current K coefficient (KF), voltage crest coefficient (CF),telephone waveform factor (THFF), peak voltage, voltage and current sequence quantity |
Temp.&HumidityMonitoring | Tempeatrue Monitoring Range: -40℃~+99℃ Humidity Monitoring Range: 20%~90% |
Leakage Current | 2-channel Leakage Current Measurement |
Accuracy | Electrical Parameter Metering Accuracy: Voltage/current level 0.2, active power/electric energy level 0.5,reactive power/electric energy level 1
Temperature Metering Accuracy: ±1℃; Temperature Metering Accuracy: ±5% |
Communication | RS485 Interface (MODBUS-RTU protocol) |
DO(Swtich Output) | 2-channel DO (Digital Output); 3A 250VAC/3A 30VDC |
DI(Swtich Input) | 6-channel DI (Digital Input); dry contact |
2. Main Parameters
Parameter | Description&Value | |
Voltage Input | Rated Voltage | 3x220~264Vac L-N |
Reference Frequency | 45~65Hz | |
Current Input | Rated Current | 3x1(6)A AC (via CTs) |
Power Supply | Source from | Voltage Input (Voltage signal input for both measurement and power supply) |
Installation | DIN-rail | 35mm standard DIN-rail Installation |
Phase Wiring | 3P4W | 3-phase 4-wire |
Safety | Insulation | All terminals and the insulation resistance between the conductive pieces not less than 100MΩ |
Withstand voltage | A-way voltage and current signal, B-way voltage and current signal, switch output and other ports should meet AC2kV 1min in pairs, the switch input and other ports should meet ac0.5kv 1mim, leakage current should be less than 2mA, no breakdown or flashover |
3. Environment
Condition | Description&Value |
Temperature | Operating Temperature: -20℃~+55℃; Storage Temperature: -40°C ~+70°C |
Humidity | ≤95%RH,no condensation,without corrosive gas |
Altitude | ≤ 2000m |
PIN/Terminal Overview of AMC16Z-ZA
Main Power Wiring Diagram of AMC16Z-ZA
Application in Data Center
Company Profile
Acrel Electric Co., Ltd Ltd. [Stock Code : 300286. SZ] is a high-tech enterprise concentrating on research, production, sales and services. It mainly provides systemic solutions of energy efficiency management and electrical safety for users. ‘Acrel’ is equipped with the complete production lines from cloud platform software to sensors. Until now, it has more than 8000 sets systemic solutions used in China to help users to realize energy visual management ,supply energy data services and improve electrical efficiency and safety. ‘Acrel’ has maintained steady growth since its listing in 2012. The company will adhere to the concept of ‘innovation,high-efficiency,unity and honesty’ and it provides more high-quality solutions,products and service for power system users and micro-grid.
Acrel Energy Efficiency Management Systems include various cloud platforms for substation operation and maintenance, electrical safety, environmental equipment monitoring and prepaid management, and many systems and related products such as intelligent transformer and distribution monitoring system, power quality management system, building energy consumption management systems, industrial energy management and control platform, leakage fire monitoring system, fire power monitoring system, fire resistant door monitoring system, emergency lighting and evacuation instructions system, charge management system for charging piles, dynamic monitoring system for data center , intelligent lighting control system,IT distribution insulation monitoring system and so on.
In order to quickly respond to customers’ demands, the company set up branches and offices in major cities in China and provides users with high-quality product experience.
Through years of accumulation and development, the company has won wide praise in product quality and service from customers at home and abroad.
Contact Us
- Acrel Electric Co., Ltd
- Contact nameShelly Zhang
- Phone86-21-18702111813
- Acrel AMC100-FAK30 AC Branch circuit ac power meter measure 30 channels AC outlet all electrical parameters and switch value status
- Acrel AMC100-FAK48AC AC multi circuit energy meter measure 48 channels AC outlet all electrical parameters and switch value status
- Acrel AMC100-FDK30 DC multi channels din rail energy metermeasure 30 channels DC outlet all electrical parameters and switch value status
- Acrel AMC100-FDK48 DC multi channels din rail power meter measure 48 channels DC outlet all electrical parameters and switch value status
- Acrel ABAT100-S-02 Battery Cell Status Monitoring System for UPS system guarantee battery pack backup time
- Acrel ABAT100-S-12 Battery Cell Status Monitoring System for UPS system guarantee battery pack backup time
- Acrel ABAT100-HS Battery Cell Status Monitoring System for UPS system guarantee battery pack backup time
- AC/DC480V Insulation Monitoring Device For Unearthed DC Systems IT Systems Below DC 40~460Hz
- Acrel AIM-T300 0-480V AC/DC system Modbus-RTU Insulation Resistance Monitoring Meter for IT Systems Metallurgical Insulation
- AC/DC480V Ground Insulation Resistance Industrial Insulation Monitoring AIM-T300 With Modbus-Rtu Used In Mines Glass Factories
- Acrel AIM-T300 Insulation Monitoring Device System Voltage AC/DC0-480V Power Supply AC85-265V RS485 Industrial Insulation
- Industrial IT Systems Insulation Monitoring and Fault Locating Solution for AC/DC480V In Industrial Fields Metallurgical Plant
- Electrical Cabinet Temperature And Humidity Adjustment Control Equipment WHD72-11 RS485 Communication And Relay Control Output
- Electrical Smart Temperature And Humidity Adjustment Controller Equipment WHD72-11 RS485 Communication AC85~265V or DC100~350V
- One Channel Temperature And Humidity Controller WHD72-11 RS485 Modbus-RTU For Distribution Cabinet Industrial and Indoor
- Acrel Top Quality WHD72-11 Series Temperature and Humidity Controller Measure One Channel Panel Meter With CE Approval Sensors
- Acrel Temperature and Humidity Controller with Sensor RS485 Communication For Electrical Distribution Cabinet Power Monitoring
- Acrel BD-AI current transmitter input AC 0-1/5A output 4-20mA power AC/DC 85-270V
- Acrel BD-3P Active power transmitter AC/DC85-270V 1 Channel analog output
- Acrel BD-4E Multi-power digital transmitter 2 channels energy impulse output Rs485 modbus-RTU
- Acrel BD-4EA Multi-power digital transmitter 2 channels energy impulse output Rs485 modbus-RTU
- Acrel BD-4P Active power transmitter AC/DC85-270V 1 Channel analog output 4-20mA
- Acrel BD-4EA Multi-power digital transmitter 2 channels energy impulse output Rs485 modbus-RTU
- AMC 100 Series AMC100-ZA Precise Power Distribution Monitoring Device Measurement of A+B Independent 2 Channels For Data Center
Find Similar Products By Category
- Measurement & Analysis Instruments > Electrical Instruments > Multimeters
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shelly Zhang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-