Home > Consumer Electronics > Water Heater & Components > Heat Pump Water Heater > Dc Inverter Split Type Heat Pump,15kw,

Dc Inverter Split Type Heat Pump,15kw,

Dc Inverter Split Type Heat Pump,15kw, photo-1
Dc Inverter Split Type Heat Pump,15kw, photo-2
Dc Inverter Split Type Heat Pump,15kw, photo-3
Negotiable MOQ: 1 Set (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
China
Type:
Water Source Heat Pump
Use:
Swimming Pool Heater
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin China
Type Water Source Heat Pump
Use Swimming Pool Heater
Installation Freestanding
Housing Material Other
Storage / Tankless Other
Rated heating: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
-Nominal heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
-Low temperature heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
-Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
-Internal and external machine connection copper pipe are 5m. If need for exceeds 7.5m, you need to contact the manufacturer to change the amount of refrigerant.
Product Description
Air Source Heat Pump Air To Water Specification


Model RF8I/bdm RF12I/bdm RF13I/bdm HF20I/bdm
Rated Heating
Heating capacity kW 9 15 18 20
Power input kW 2.59 4.31 5.14 5.81
COP W/W 3.47 3.48 3.5 3.44
Nominal Heating Heating capacity kW 5.53 10.5 12.1 14.5
Power input kW 2.34 4.43 5.13 6.01
COP W/W 2.36 2.37 2.36 2.41
Low Temp. Heating IPLV(H) W/W 2.8 2.85 2.85 2.86
Heating capacity kW 4.5 8.9 10.1 12.5
Power input kW 2.34 4.56 5.1 5.95
COP W/W 1.92 1.95 1.98 2.1
Rated Cooling Cooling capacity kW 8 11.5 12
Power input kW 3.2 4.6 4.8
EER W/W 2.5 2.5 2.5
Power Supply V/Ph/Hz 220/1/50
Max. Power Input (With E-Heater) kW 4.4(+3) 5.2(+3) 6.6(+3) 7.1(+3)
Max. Current Input A 20(+13.6) 23.7(+13.6) 30(+13.6) 32.5(+13.6A)
(With E-Heater)
Max. Water Temp. 58
(Without E-Heater)
Working Range -30 to 43 -35 to 43
(Ambient temp.)
Refrigeration Circulation Refrigerant Type R410A
Qty./Kg 1.7 3.15 3.15 3.15
Compressor Qty. 1
Type DC INVERTER DOUBLE ROTOR EVIDCINVERTER
DOUBLEROTOR
Evaporator Type High efficiency hydrophilic aluminum foil fin heat exchanger
EEV Type Electronic Expansion Valve
Fan Motor Qty. 1 2
Power 140 2*150
Input(W)
Fan Blades Size mm Φ560*139 Φ525*135
Liquid valve size inch(mm) 3/8"(9.52)
Gas valve size inch(mm) 5/8"(15.88)
Water System Condenser Type Tube in tube heat exchanger
Water Pump Type Shielded pump
Water Flow m³/h 1.38 1.98 2.06 2.5
Water Drop kpa 35 35 38 48
Air Vent Valve Type Standard
Pressure Release Valve Type Standard
Pressure 3kgs
value
E-Heater kW 3
Buffer Tank L 5
Water Inlet/Outlet inch(mm) 5/4" male
Pipe Size
Net Dimensions indoor Unit mm 760x510x330
(L*W*H)
Outdoor Unit mm 947x403x813 940x393x1373
(L*W*H)
Package Size indoor Unit mm 795x562x373
(L*W*H)
Outdoor Unit mm 1050x468x847 1060x490x1395
(L*W*H)
N.W. Indoor Unit kg 43
Outdoor Unit kg 63 110 115
G.W. Indoor Unit kg 48
Outdoor Unit kg 70 125 130
Noise
Level
Indoor Unit dB(A) ≤35
Outdoor Unit dB(A) ≤59.5 ≤61.5 ≤62

Air energy heat pump is to use the heat in the air to generate heat energy, can 24 hours a day, high water pressure, constant temperature to provide the whole family with different hot water, heating and cooling needs, and at the same time to consume the least energy to complete the above requirements.

The principle

Air energy heat pumps operate on the "reverse Carnot" principle, the reverse Carnot cycle principle. Operating through a compressor system, it absorbs heat from the air to produce hot water. The specific process is: the compressor compresses the refrigerant, the temperature rises after compression, and the refrigerant passes through the condenser in the tank to produce hot water. The refrigerant after heat exchange returns to the compressor for the next cycle. In this process, the air heat is absorbed into the refrigerant through the evaporator, and the refrigerant is introduced into the water to produce hot water. Air heat pump water heater is a new generation of water heater which is heated by compressor air. Metaphorically speaking, the "outdoor machine" compresses the air like a pump, raising the temperature of the air, and then conducts heat to the indoor water storage tank through a liquid that will boil at -17 ° C, and then releases heat to the water.

The heat pump works on the principle of heating, as opposed to air conditioning refrigeration - the national refrigeration standard is 1000 watts, and electric refrigeration is 2800 watts. According to the principle of heat balance, at least 2800 watts of heat is generated at the same time, plus the input of 1000 watts of electricity, the actual heat generated in 3000- 4000 watts, the heat is transported to the insulated water tank, its power consumption is only a quarter of the electric water heater (even if the thermal efficiency is 100%, the input of 1000 electricity is only 1000 watts of heat).

Air-powered water heaters do not require sunlight, so they can be placed at home or outside. Therefore, most of the manufacturers of the machine have a separate machine and a machine, solar water heater storage after the water is used up, it is difficult to immediately produce hot water. If the electric heating takes a long time, and the air heater as long as there is air, the temperature is above zero degrees Celsius, it can operate 24 hours a day under pressure. In this way, once a tank of water is used, another tank of hot water will be produced in an hour or so. At the same time, it can fundamentally eliminate the electric water heater leakage, dry burning and gas water heater when the use of harmful gas and other safety hazards, overcome the solar water heater overcast and rainy days can not be used and installation inconvenience and other shortcomings, with high safety, high energy saving, long life, no gas emissions and many other advantages. Air energy water heaters generally have a life span of 10 to 15 years.

The installation

Air energy heat pump is usually installed in the kitchen balcony, the outlet is linked to the kitchen through the air duct, so that the cold air blown out can directly enter the kitchen, to achieve the effect of refrigeration. When installing, only the cold and hot water mouth and the house reserved cold and hot water link, can be used, the installation is very simple, but the effect is not too good.


Product Tags: Air Heat Pump , Heat Pump , Air Conditioning Appliances , Air energy heat pump , monoblock-type-heat-pump

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
8Yrs
Verified Business License
Business Type
Trading Company
Year Established
2015
Overseas Office
Yes
Factory Size
Below 1,000 square meters

Recommended Categories

Explore top categories and find suppliers for your specific needs