Module Spare Parts 07EA90-SI GJR5251200R0101
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| 07EA90-SI GJR5251200R0101 |
During SIMV PC mode, the ventilator delivers synchronized pressure-controlled breaths, the number of which is determined by the set respiratory rate (Rate). All other spontaneous efforts are delivered as pressure-supported breaths. Backup ventilation is available in SIMV PC mode. Set a Backup Mode on the Current Mode > Mode Settings menu. Tube Comp, Leak Comp, and Trigger Comp may be set if desired. The following settings are available in SIMV PC mode: Category Setting Main Parameters FiO2 Pinsp PEEP PS Breath Timing Rate Tinsp Patient Synchrony Insp Trigger Exp Trigger Bias Flow PS Rise Time Rise Time Safety Pmax AB.100.030 1 5 7 6 4 8 9 2 3 Figure 5-6 • SIMV PC waveforms Note Note CARESCAPE™ R860 5-20 2065490-001 1. Airway pressure (Paw) waveform 2. Inspiratory time (Tinsp) 3. Spontaneous breathing time 4. Pressure-supported breath 5. Inspiratory pressure (Pinsp) 6. Flow waveform 7. Trigger window 8. PEEP 9. Tidal Volume (VT) 5 Ventilation modes 2065490-001 5-21 Synchronized intermittent mandatory ventilation pressure regulated volume control (SIMV PRVC) SIMV PRVC mode is a purchasable option. During SIMV PRVC mode, the ventilator delivers synchronized pressure regulated volume controlled breaths at the set respiratory rate (Rate). For each mechanical breath, the ventilator adjusts the inspiratory pressure to use the lowest pressure required to deliver the tidal volume. All other spontaneous efforts are delivered as pressure-supported breaths. To determine the patient’s lung compliance, the ventilator delivers volume controlled ventilation for 10 seconds or two inspiratory periods, whichever is longer when the mode is initiated. Based on the patient’s lung compliance, the inspiratory pressure is established and used for subsequent breaths. The ventilator uses the following pressure range when adjusting inspiratory pressure: • Low limit: PEEP + Pmin • High limit: Pmax - 5 cmH2O The difference in inspiratory pressure between breaths does not exceed ±3 cmH2O. If a high airway pressure alarm is active for the current breath, the next breath’s pressure target is 0.5 cmH2O lower. Backup ventilation is available in SIMV PRVC mode. To set a Backup Mode, select Current Mode > Mode Settings and select Backup Mode. Tube Comp, Leak Comp, and Trigger Comp modes may be set if desired. The following settings are available in SIMV PRVC mode
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts104X905BA603 G-95-149-H-9550US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts106M1081-01US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 10QT01 GJR2209300R0001 10QT01A-ER0001US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 216EA62 1MRB178066R1E 1MRB150083R1E 1MRB300162R0008US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 216NG63A HESG441635R1 HESG216877KUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 216VC62AUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 2364-SPM03AUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 3200-1214-03US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 320-1026CUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 3BHE024747R0101US$ 1 - 100000MOQ: 1 Piece