Module Spare Parts 086318-002 086318-501
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| 086318-002 086318-501 |
APRV mode is a purchasable option. APRV mode is intended to be used on spontaneously breathing patients. During APRV mode, the ventilator alternates between a set high (Phigh) and low (Plow) pressure level. The ventilator will deliver the set (Phigh) pressure for the set (Thigh) duration of time. The ventilator will deliver the set (Plow) pressure for the set (Tlow) duration of time. The patient can initiate spontaneous breaths at either level. Backup ventilation is available in APRV mode. To set Backup Mode, select Current Mode > Mode Settings and select Backup Mode. Tube Comp, Leak Comp, and Trigger Comp may be set if desired. The following settings are available in APRV mode: Category Setting Main Parameters FiO2 Phigh Plow Breath Timing Thigh Tlow Patient Synchrony Insp Trigger Bias Flow Rise Time Safety Pmax AB.100.204 1 2 3 4 6 5 Figure 5-11 • APRV waveforms Note Note Note CARESCAPE™ R860 5-30 2065490-001 1. Airway pressure (Paw) waveform 2. Thigh 3. Tlow 4. Phigh 5. Plow 6. Flow waveform 5 Ventilation modes 2065490-001 5-31 Volume Support (VS) VS mode is a purchasable option. VS mode is intended to be used on spontaneously breathing patients. During VS, the patient initiates spontaneous breaths and determines respiratory rate and timing. The ventilator maintains a PEEP level and provides support to deliver the set tidal volume (VT). For each breath, the ventilator adjusts the inspiratory pressure to use the lowest pressure required to deliver the tidal volume. To determine the patient’s lung compliance, the ventilator delivers volume-controlled ventilation for 10 seconds or two inspiratory periods, whichever is longer when the mode is initiated. Based on the patient's lung compliance, the inspiratory pressure is established and used for subsequent breaths. The ventilator uses the following pressure range when adjusting inspiratory pressure: • Low limit: PEEP + Pmin • High limit: Pmax - 5 cmH2O The difference in inspiratory pressure between breaths does not exceed ±3 cmH2O. When the Minimum Rate is set during VS, the ventilator will deliver a mechanical breath if the patient's spontaneous respiratory rate is less than the Minimum Rate. The mechanical breath will be delivered at the Backup Pinsp pressure setting for the time duration of the Backup Tinsp setting. If a high airway pressure alarm is active for the current breath, the next breath’s pressure target is 0.5 cmH2O lower. Backup ventilation is available in VS mode. To set a Backup Mode, select Current Mode > Mode Settings and select Backup Mode. Tube Comp, Leak Comp, and Trigger Comp may be set if desired. The following settings are available in VS mode
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts 216EA62 1MRB178066R1E 1MRB150083R1E 1MRB300162R0008US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 216NG63A HESG441635R1 HESG216877KUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 216VC62AUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 2364-SPM03AUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 3200-1214-03US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 320-1026CUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 3BHE024747R0101US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 3BHE027632R0101US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 416NHM30030US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 416NHM30032AUS$ 1 - 100000MOQ: 1 Piece