Module spare parts 086318-002 086318-501
- 1 Piece / Pieces per Month
- xiamen
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
Product Details
Brand Name: | ABB | Model Number: | 086318-002 086318-501 |
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
086318-002 086318-501 |
APRV mode is a purchasable option. APRV mode is intended to be used on spontaneously breathing patients. During APRV mode, the ventilator alternates between a set high (Phigh) and low (Plow) pressure level. The ventilator will deliver the set (Phigh) pressure for the set (Thigh) duration of time. The ventilator will deliver the set (Plow) pressure for the set (Tlow) duration of time. The patient can initiate spontaneous breaths at either level. Backup ventilation is available in APRV mode. To set Backup Mode, select Current Mode > Mode Settings and select Backup Mode. Tube Comp, Leak Comp, and Trigger Comp may be set if desired. The following settings are available in APRV mode: Category Setting Main Parameters FiO2 Phigh Plow Breath Timing Thigh Tlow Patient Synchrony Insp Trigger Bias Flow Rise Time Safety Pmax AB.100.204 1 2 3 4 6 5 Figure 5-11 • APRV waveforms Note Note Note CARESCAPE™ R860 5-30 2065490-001 1. Airway pressure (Paw) waveform 2. Thigh 3. Tlow 4. Phigh 5. Plow 6. Flow waveform 5 Ventilation modes 2065490-001 5-31 Volume Support (VS) VS mode is a purchasable option. VS mode is intended to be used on spontaneously breathing patients. During VS, the patient initiates spontaneous breaths and determines respiratory rate and timing. The ventilator maintains a PEEP level and provides support to deliver the set tidal volume (VT). For each breath, the ventilator adjusts the inspiratory pressure to use the lowest pressure required to deliver the tidal volume. To determine the patient’s lung compliance, the ventilator delivers volume-controlled ventilation for 10 seconds or two inspiratory periods, whichever is longer when the mode is initiated. Based on the patient's lung compliance, the inspiratory pressure is established and used for subsequent breaths. The ventilator uses the following pressure range when adjusting inspiratory pressure: • Low limit: PEEP + Pmin • High limit: Pmax - 5 cmH2O The difference in inspiratory pressure between breaths does not exceed ±3 cmH2O. When the Minimum Rate is set during VS, the ventilator will deliver a mechanical breath if the patient's spontaneous respiratory rate is less than the Minimum Rate. The mechanical breath will be delivered at the Backup Pinsp pressure setting for the time duration of the Backup Tinsp setting. If a high airway pressure alarm is active for the current breath, the next breath’s pressure target is 0.5 cmH2O lower. Backup ventilation is available in VS mode. To set a Backup Mode, select Current Mode > Mode Settings and select Backup Mode. Tube Comp, Leak Comp, and Trigger Comp may be set if desired. The following settings are available in VS mode
Contact Us
- Xiamen xiongba e-commerce Co., Ltd
ABB | EPRO | PROSOFT | NI |
REXROTH | Schneider | Miscellaneous brand | EMERSON |
SEW | SIEMENS | GE | SST |
A-B | TRICONEX | WATLOW | WOODWARD |
YAMATAKE | YOKOGAWA | HONEYWEL | BENTLY |
FOXBORO | FSC | ENTERASYS | HIMA |
TRIPLEX |
- 216NG62A HESG441634R1/K Automation controller module
- 216DB61 HESG324063R100/J Excitation control system components Realize the connection between PLC and business application
- AUX111 Displacement sensor With high precision
- 6DD1683-0CC0 Fan extraction unit
- A06B-6114-H106 Servo amplifier Motion position control system
- BRC300 Bridge controller Accurate measurement ability
- BRC300 Bridge controller Accurate measurement ability
- PM3328B-6-1-3-E Process control system module
- FCP270 P0917YZ Control processor
- MPL-B540D-MJ24AA Industrial automation control system Responsible for receiving from sensors
- MPL-B540D-MJ24AA Industrial automation control system Responsible for receiving from sensors
- IOCN200-566-000-112 Key module Realize high-speed digital signal acquisition
- triconex 4101 controller Redundant design is adopted
- IC697CPM790-GD CPU processor module Ability to process large amounts of data quickly
- HCMCO3MC-1A coprocessor Support network
- ATCS-15 Thermostatic controller Maintain a constant temperature
- DS200DCFBG1BGB Power strip
- DS200TBQCG1AAA Analog terminal board With two terminals
Popular Searches
- lightning conductor
- Copper Lightning Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
- earthing material
- Clad Steel Ground Rod
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-