STAHL ET-436-AT-R2-HB-TX-100GB-V
- 149 Piece / Pieces per Month
- T/T
- 1 days
Product Details
Brand Name: | STAHL | Place of Origin: | China | Model Number: | ET-436-AT-R2-HB-TX-100GB-V |
Product Description
Brand:STAHL
Type:ET-436-AT-R2-HB-TX-100GB-V
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
In this operating mode the turbine’s HP and LP valve actions are fully decoupled. The HP valve can be positioned by the 505E’s Speed, Cascade, or Auxiliary PIDs. The LP valve can only be positioned by the 505E’s Extr/Adm PID. The decoupled configuration allows control of a turbine’s inlet pressure without interaction from exhaust flow changes. With this mode of operation, turbine exhaust pressure is controlled by only moving the LP valve. The turbine’s HP and LP valve actions are also decoupled to control turbine exhaust pressure/flow without interaction from turbine inlet pressure or flow changes. Turbine inlet pressure is controlled by only moving the HP valve, thus no change in exhaust pressure/flow is created. For a change in either process the respective valves are repositioned for a net effect of no pressure or flow change on the other process. With this mode of operation, turbine inlet pressure can be controlled through either the 505E’s Auxiliary or Cascade PIDs and turbine exhaust pressure is controlled through the Ext/Adm PID. Although turbine load is not controlled with this configuration, it is recommended to use the Auxiliary PID as a load limiter for unit protection. Block Diagram Description The block diagrams displayed below provide a detailed view of each Ratio/Limiter configuration and the relationship between the ratio/limiter’s input and output signals. The ‘S’ input signal originates from the Speed/auxiliary LSS buss and represents Speed, Load, Aux PID, or Casc PID demand. The ‘P’ input signal originates from the Ext/Adm PID or the E/A demand setpoint, depending on selected modes, and represents Ext/Adm flow demand. The ‘DC’ input signal is a discrete signal that originates from the control’s decoupling map logic and goes to a true state when ratio/limiter decoupling is selected. The ‘S’ and ‘P’ signals must pass through map limiters, depending on the priority selected, before they are used in the ratioing equations. Only one parameter (S or P) at a time can be limited, thus if speed priority is enabled, only the P signal is limited. If Ext/ Adm priority is selected, only the S signal is limited. These limiters allow the valves to be correctly positioned on each turbine operating limit. To simplify the limiter logic, the Min (HSS bus) and Max (LSS bus) limiters are displayed as one limiter bus. Each possible turbine operating limit is labeled and displayed graphically.
All Limiters are based on the entered steam map values and actual HP & LP valve positions (as derived from the control’s actuator driver signals). Once the ‘S’ and ‘P’ signals pass through their respective limiters, they are referred to as S’ (S-prime) and P’ (P-prime). When the turbine is not operating on a limit, the S’ value equals the S input signal and the P’ value equals the P input signal. If programmed for decoupled operation, digital ramps are used to transfer between Ratio/ Limiters. During normal enabling and disabling of the decoupled ratio/limiter mode, these ramps take 50 seconds to completely ramp from one ratio/limiter to the next. with generator applications, this transfer is made within 40 milliseconds when switching to frequency control (gen or tie breaker opens).
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Popular Searches
- lightning conductor
- Copper Lightning Rod
- Lightning Rod Clamp Earth Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- Air Blower Electrostatic Eliminator
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
Recommended Products
- phase loss protector Precision three-phase 380V water pump motor intelligent protector With fault code prompt
- 380V 3 phase intelligent digital display water pump/motor circuit breaker phase loss protector 40A 100A overload phase loss motor protector
- AB 1769-PB4 COMPACTLOGIX 4A POWER SUPPLY 24V DC
- AB 1769-PA2 COMPACTLOGIX 2A POWER SUPPLY 120/240V AC
- AB 1769-OW8I COMPACTLOGIX 8DO 5-265V AC/5-125V DC RELAY MODULE ISOLATED
- AB 1769-OW8 COMPACTLOGIX 8DO 5-265V AC/5-125V DC RELAY MODULE
- AB 1769-OA16 COMPACTLOGIX 16DO 85-265V AC MODULE
- AB 1769-L32E COMPACTLOGIX L3 PROCESSOR ENET 750KB
- AB 1769-L32C COMPACTLOGIX L3 PROCESSOR CNET 750KB
- AB 1769-L32C COMPACTLOGIX L3 PROCESSOR CNET 750KB
- AB 1769-L18ER-BB1B COMPACTLOGIX 5370-L1 PROCESSOR 16DI/16DO 512KB
- AB 1769-IA16 COMPACTLOGIX 16DI 79-132V AC MODULE
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile