BENTLY 3500/53 133388-01

BENTLY 3500/53 133388-01 photo-1
US$ 1115 - 2025 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
BENTLY 3500/53 133388-01
Place of Origin:
China
Model Number:
BENTLY 3500/53 133388-01
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
1 days
Brand Name BENTLY 3500/53 133388-01
Place of Origin China
Model Number BENTLY 3500/53 133388-01

Brand: BENTLY 

Type:3500/53 133388-01

Origin: the United States

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

The maximum total limit on CEX-Bus is the electrical one, there might be further limitations due to performance for a particular unit. (3) Only one port (CH1) is used in the interfaces CI868, CI871 and CI873. If redundant controllers (PM8XX) are used along with redundant communication interfaces, it ensures full redundancy and supports the online upgrade of firmware.It is recommended to make a practice of always starting an IPConfig session with a “Restore factory settings” command before assigning the intended IP addresses. This will erase previously stored alternative MAC and IP addresses if any

Single CPU Configurations The IP address of the CN1 port on the controller is set using the IPConfig tool (this tool is installed together with the 800xA system). See IPConfig online help. If network redundancy is used, make sure that the CN1 port is connected to the primary network, and the CN2 port is connected to the secondary network. In this case, you also have to set the IP address for the CN2 port. See IPConfig online help. Redundant CPU Configurations In configurations with redundant CPU, the IP address must be set as follows:Set the IP address of the CN1 port on the backup CPU. Use default settings (0.0.2.0 is added to the address of the primary CPU), unless your network administrator requires otherwise. See IPConfig online help.4. Start your 800xA Workplace. 5. Create a representation of the controller in the Project Explorer hardware tree. Make sure the PM861/PM864/PM865/PM891 processor unit is defined as redundant. See Control Builder online help. 6. In Project Explorer, set the IP address of the controller to the IP address of the primary CPU. See Control Builder online help. 7. Switch on the secondary CPU. Check that you have communication with the controller.There is no need to set IP address(es) for the backup CPU in Control Builder. The IP address of the backup CPU, CN1 and CN2 ports will only be used for internal communication between the primary and backup CPUs. 

When the backup CPU takes over, it also takes over the primary IP address that is defined in Control Builder. Other units on the control network will never notice the switchover.I/O Systems There are several methods of connecting I/O systems to the AC 800M Controller: • S100 I/O via CI856. • S800 I/O units via the ModuleBus. Support for hot configuration during run, redundancy on all levels, HART routing, and Sequence-of-Events (SOE). • S800 I/O units via CI854/CI854A and CI840/CI840A, PROFIBUS DP. Support for HART routing, redundancy on all levels, and hot configuration during run.


Product Tags: DCS module , The PLC card a , The controller

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs