BENTLY 3500/53 133388-01
Brand: BENTLY
Type:3500/53 133388-01
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
The maximum total limit on CEX-Bus is the electrical one, there might be further limitations due to performance for a particular unit. (3) Only one port (CH1) is used in the interfaces CI868, CI871 and CI873. If redundant controllers (PM8XX) are used along with redundant communication interfaces, it ensures full redundancy and supports the online upgrade of firmware.It is recommended to make a practice of always starting an IPConfig session with a “Restore factory settings” command before assigning the intended IP addresses. This will erase previously stored alternative MAC and IP addresses if any
Single CPU Configurations The IP address of the CN1 port on the controller is set using the IPConfig tool (this tool is installed together with the 800xA system). See IPConfig online help. If network redundancy is used, make sure that the CN1 port is connected to the primary network, and the CN2 port is connected to the secondary network. In this case, you also have to set the IP address for the CN2 port. See IPConfig online help. Redundant CPU Configurations In configurations with redundant CPU, the IP address must be set as follows:Set the IP address of the CN1 port on the backup CPU. Use default settings (0.0.2.0 is added to the address of the primary CPU), unless your network administrator requires otherwise. See IPConfig online help.4. Start your 800xA Workplace. 5. Create a representation of the controller in the Project Explorer hardware tree. Make sure the PM861/PM864/PM865/PM891 processor unit is defined as redundant. See Control Builder online help. 6. In Project Explorer, set the IP address of the controller to the IP address of the primary CPU. See Control Builder online help. 7. Switch on the secondary CPU. Check that you have communication with the controller.There is no need to set IP address(es) for the backup CPU in Control Builder. The IP address of the backup CPU, CN1 and CN2 ports will only be used for internal communication between the primary and backup CPUs.

Send Inquiry to This Supplier
You May Also Like
-
BENTLY 1900/65A-01-02-01-00-00US$ 1204 - 2213MOQ: 1 Piece
-
BENTLY 128229-01US$ 1045 - 2265MOQ: 1 Piece
-
BENTLY 3500/15 106M1079-01US$ 1045 - 2265MOQ: 1 Piece
-
BENTLY 3500/92 136180-01US$ 1072 - 2063MOQ: 1 Piece
-
BENTLY 125760-01US$ 1100 - 2010MOQ: 1 Piece
-
BENTLY 125768-01US$ 1100 - 2010MOQ: 1 Piece
-
BENTLY 136719-01US$ 1100 - 2010MOQ: 1 Piece
-
BENTLY 3500/20 125744-02US$ 1100 - 2010MOQ: 1 Piece
-
BENTLY 3500/32 125712-01US$ 1101 - 2011MOQ: 1 Piece
-
BENTLY 125720-01US$ 1101 - 2011MOQ: 1 Piece