07CR41 07DC91C ABB Controller Spot Warranty
Our Email: 2235954483@qq.com
contact number:13313705507
contacts:HE
In general, the technical system data listed under "System data and system configuration" in chapter 1 of volume 2 of
the "Advant Controller 31" system description are valid. Additional data or data which are different from the system data
are listed as follows.
Technical data for the complete unit
Permissible temperature range during operation 0...55 °C
Rated supply voltage 24 V DC
Max. current consumption 0.2 A
Max. power dissipation 5 W
Protection against reversed polarity of power connection yes
Number of binary inputs 1 as enabling input for the analog outputs
Number of analog input channels 8 or 16, depending on the operating mode
Number of analog output channels 8 or 16, depending on the operating mode
Electrical isolation CS31 system bus interface from the rest of the unit,
1 binary input from the rest of the unit
Address setting and configuration Coding switch under the cover located on the
right side of the housing
Diagnosis see chapter "Diagnosis and displays"
Operation and error displays a total of 17 LEDs,
see chapter "Diagnosis and displays"
Method of connections removable screw-type terminal blocks
supply terminals, CS31 system bus max. 1 x 2.5 mm2 or max. 2 x 1.5 mm2
all other terminals max. 1 x 1.5 mm2
Max. length of the analog cables,
two-core shielded and cross section > 0.5 mm2 100 m
Conversion error of the analog values
(non-linearity, factory calibration and resolution) typ. 0.5 %, max. 1 %
Max. permissible potential difference between
terminal M (minus of the supply voltage) and
terminals AGND (minus of analog inputs and outputs) ± 1 V
Common reference potential for all analog signals AGND (minus terminal of analog inputs and outputs)
Electrical isolation of analog signals none (see also Fig. 5.4-2).
Technical data of the binary input (enabling input for analog outputs)
The analog outputs must be enabled by a binary 1 signal (24V) at terminals 25 (+) and 26 (-).
Signal level 0 signal (-30...+5 V) voltage outputs are at 0 V,
current outputs are at 0 mA
1 signal (+13...+30 V) analog outputs are active
Electrical isolation yes, i.e. the reference potential and the
control signal must be connected
Send Inquiry to This Supplier
You May Also Like
-
216AB61 HESG324013R0100 HESG435572P1 ABB Spot WarrantyUS$ 10 - 166MOQ: 1 Pound
-
216EA61b 216EA62 ABB Spot WarrantyUS$ 10 - 90MOQ: 1 Pound
-
216GD61a HESG324436R3/A ABB Advantageous SupplyUS$ 165 - 166MOQ: 1 Pound
-
216NG63A HESG441635R1 HESG216877K ABB Module Card StockUS$ 113 - 260MOQ: 1 Pound
-
ABB 5SHX2645L0006 3BHB012961R0002 Thyristor IGCTUS$ 100 - 260MOQ: 1 Pound
-
5SHY3545L0001 5SHY3545L0002 ABB Spot WarrantyUS$ 113 - 260MOQ: 1 Pound
-
5SHY3545L0003 ABB 3BHB004692R0001 Spot WarrantyUS$ 100 - 200MOQ: 1 Pound
-
5SHY3545L0009 3BHB013085R0001 ABB PLC ThyristorUS$ 190 - 260MOQ: 1 Pound
-
5SHY3545L0010 3BHB013088R0001 ABB IGCT ModuleUS$ 100 - 200MOQ: 1 Pound
-
5SHY3545L0014 IGCT ABB Thyristor ModuleUS$ 100 - 200MOQ: 1 Pound