19/3.18 Mulberry Aaac Conductor All Aluminum Alloy Concentric Cable Factory Direct Price


AAAC-Aluminum Alloy Overhead Bare Conductor is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical teatures exist.

Duplex service drop |
||||||||||||||||||
Code Name |
Phase conductor |
Bare Neutral Message |
Nominal Weight ( kg/km ) |
Allowable Ampacity |
||||||||||||||
Size & No.of wires |
Insulation Thick(mm) |
Nominal Diameter (mm) |
Size & No.of wires |
Rated Strength (kg) |
XLPE |
Aluminum |
( A ) |
|||||||||||
Bare |
OD |
|||||||||||||||||
AAC |
||||||||||||||||||
Pekingese |
6-Solid |
1.14 |
4.1 |
6.4 |
6-7 |
255 |
20.8 |
72.9 |
78 |
|||||||||
Collie |
6-7 |
1.14 |
4.6 |
6.9 |
6-7 |
255 |
23.8 |
72.9 |
78 |
|||||||||
Cocker |
6-7 |
1.52 |
4.6 |
7.7 |
6-7 |
255 |
32.7 |
72.9 |
78 |
|||||||||
Dachshund |
4-Solid |
1.14 |
5.2 |
7.5 |
6-7 |
400 |
26.8 |
114.6 |
103 |
|||||||||
Spaniel |
4-7 |
1.14 |
5.9 |
8.2 |
6-7 |
400 |
29.8 |
116.1 |
103 |
|||||||||
Cairn |
4-7 |
1.52 |
5.9 |
8.9 |
6-7 |
400 |
40.2 |
116.1 |
103 |
|||||||||
Doberman |
2-7 |
1.14 |
7.4 |
9.7 |
2-7 |
612 |
38.7 |
184.5 |
136 |
|||||||||
Airedale |
1-19 |
1.52 |
8.4 |
11.5 |
1-7 |
- |
56.5 |
233.6 |
158 |
|||||||||
Basset |
1/0-7 |
1.52 |
9.3 |
12.4 |
1/0-7 |
903 |
64 |
294.7 |
182 |
|||||||||
Malemure |
1/0-19 |
1.52 |
9.4 |
12.5 |
1/0-7 |
903 |
64 |
294.7 |
182 |
|||||||||
AAAC |
||||||||||||||||||
Chihuahua |
6-Solid |
1.14 |
4.1 |
6.4 |
6-7 |
499 |
20.8 |
72.9 |
78 |
|||||||||
VIzsla |
6-7 |
1.14 |
4.6 |
6.9 |
6-7 |
499 |
23.8 |
72.9 |
78 |
|||||||||
Harrier |
4-Solid |
1.14 |
5.2 |
7.5 |
4-7 |
798 |
26.8 |
116.1 |
103 |
|||||||||
Whippet |
4-7 |
1.14 |
5.9 |
8.2 |
4-7 |
798 |
29.8 |
116.1 |
103 |
|||||||||
Schnauzer |
2-7 |
1.14 |
7.4 |
9.7 |
2-7 |
1270 |
38.7 |
184.5 |
136 |
|||||||||
Afghan |
1/0-7 |
1.52 |
9.3 |
12.4 |
1/0-7 |
2023 |
64 |
296.1 |
182 |
|||||||||
Hocler |
1/0-19 |
1.52 |
9.4 |
12.5 |
1/0-7 |
2023 |
64 |
296.1 |
182 |
|||||||||
ACSR |
||||||||||||||||||
Setter |
6-Solid |
1.14 |
4.1 |
6.4 |
6/6/01 |
540 |
20.8 |
72.9 |
78 |
|||||||||
Shepherd |
6-7 |
1.14 |
4.6 |
6.9 |
6/6/01 |
540 |
23.8 |
72.9 |
78 |
|||||||||
Retriever |
6-7 |
1.52 |
4.6 |
7.7 |
6/6/01 |
540 |
32.7 |
72.9 |
78 |
|||||||||
Eskimo |
4-Solid |
1.14 |
5.2 |
7.5 |
4/6/01 |
844 |
26.8 |
114.6 |
103 |
|||||||||
Terrier |
4-7 |
1.14 |
5.9 |
8.2 |
4/6/01 |
844 |
29.8 |
116.1 |
103 |
|||||||||
Yorkshirc |
4-7 |
1.52 |
5.9 |
8.9 |
4/6/01 |
844 |
40.2 |
116.1 |
103 |
|||||||||
Chow |
2-7 |
1.14 |
7.4 |
9.7 |
2/6/01 |
1293 |
38.7 |
184.5 |
136 |
|||||||||
Labrador |
1-19 |
1.52 |
8.4 |
11.5 |
1/6/01 |
1610 |
56.5 |
233.6 |
158 |
|||||||||
Bloodhound |
1/0-7 |
1.52 |
9.3 |
12.4 |
1/0-6/1 |
1987 |
64 |
294.7 |
182 |
|||||||||
Bull |
1/0-19 |
1.52 |
9.4 |
12.5 |
1/0-6/1 |
1987 |
64 |
294.7 |
182 |
|||||||||
Applications of Duplex ABC cable |
To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum. |
|||||||||||||||||
Applications of Triplex ABC cable |
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. |
|||||||||||||||||
Applications of Quadruplex ABC cable |
Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors |
|||||||||||||||||
IEC 61089 |
||||||||||||
Code Name |
Nominal |
No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
||||||
mm2 |
No./mm |
mm |
kg/km |
KN |
ohm/km |
|||||||
10 |
10 |
7/1.35 |
4.05 |
27.4 |
2 |
2.8633 |
||||||
16 |
16 |
7/1.71 |
5.13 |
43.8 |
3 |
1.7896 |
||||||
25 |
25 |
7/2.13 |
6.39 |
68.4 |
4.5 |
1.1453 |
||||||
40 |
40 |
7/2.70 |
8.1 |
109.4 |
6.8 |
0.7158 |
||||||
63 |
63 |
7/3.39 |
10.17 |
172.3 |
10.4 |
0.4545 |
||||||
100 |
100 |
19/2.59 |
12.95 |
274.8 |
17 |
0.2877 |
||||||
125 |
125 |
19/2.89 |
14.45 |
343.6 |
21.3 |
0.2302 |
||||||
160 |
160 |
19/3.27 |
16.35 |
439.8 |
26.4 |
0.1798 |
||||||
200 |
200 |
19/3.66 |
18.3 |
549.7 |
32 |
0.1439 |
||||||
250 |
250 |
19/4.09 |
20.45 |
687.1 |
40 |
0.1151 |
||||||
315 |
315 |
37/3.29 |
23.03 |
867.9 |
52 |
0.0916 |
||||||
400 |
400 |
37/3.71 |
25.97 |
1102 |
64 |
0.0721 |
||||||
450 |
450 |
37/3.94 |
27.58 |
1239.8 |
72 |
0.0641 |
||||||
500 |
500 |
37/4.15 |
29.05 |
1377.6 |
80 |
0.0577 |
||||||
560 |
560 |
37/4.39 |
30.73 |
1542.9 |
89.6 |
0.0515 |
||||||
630 |
630 |
61/3.63 |
32.67 |
1738.3 |
100.8 |
0.0458 |
||||||
710 |
710 |
61/3.85 |
34.65 |
1959.1 |
113.6 |
0.0407 |
||||||
800 |
800 |
61/4.09 |
36.81 |
2207.4 |
128 |
0.0361 |
||||||
900 |
900 |
61/4.33 |
38.97 |
2483.3 |
144 |
0.0321 |
||||||
1000 |
1000 |
61/4.57 |
41.13 |
2759.2 |
160 |
0.0289 |
||||||
1120 |
1120 |
91/3.96 |
43.56 |
3093.5 |
179.2 |
0.0258 |
||||||
1250 |
1250 |
91/4.18 |
45.98 |
3452.6 |
200 |
0.0231 |
||||||
1400 |
1400 |
91/4.43 |
48.73 |
3866.9 |
224 |
0.0207 |
||||||
1500 |
1500 |
91/4.58 |
50.38 |
4143.1 |
240 |
0.0193 |
||||||
ASTM B 399/B 399M |
||||||||||||||||
Code Name |
Total Area |
1350 Grade Equivalent |
No./Dia. of Wire |
Approx. Overall Diameter |
Approx. Weight |
Calculated Breaking Load |
Max.DC Resista-nce at 20° C |
|||||||||
AWG or MCM |
mm2 |
(Approx.)
AWG or MCM
|
No. / mm |
mm |
kg/km |
kN |
Ohm/km |
|||||||||
Akron |
30.6 |
15.5 |
6 |
7/1.68 |
5.04 |
43 |
4.9 |
2.1588 |
||||||||
Alton |
48.7 |
24.7 |
4 |
7/2.12 |
6.36 |
68 |
7.8 |
1.3557 |
||||||||
Ames |
77.5 |
39.2 |
2 |
7/2.67 |
8.01 |
108 |
12.4 |
0.8547 |
||||||||
Azusa |
123.3 |
62.4 |
1 |
7/3.37 |
10.11 |
171 |
18.9 |
0.5365 |
||||||||
Anaheim |
155.4 |
78.6 |
2/0 |
7/3.78 |
11.34 |
216 |
23.8 |
0.4264 |
||||||||
Amherst |
195.7 |
99.3 |
3/0 |
7/4.25 |
12.75 |
272 |
30 |
0.3373 |
||||||||
Alliance |
246.9 |
125.1 |
4/0 |
7/4.77 |
14.31 |
343 |
37.8 |
0.2678 |
||||||||
Butte |
312.8 |
158.6 |
266.8 |
19/3.26 |
16.3 |
435 |
46.5 |
0.2112 |
||||||||
Canton |
394.5 |
199.9 |
336.4 |
19/3.66 |
18.3 |
548 |
58.6 |
0.1676 |
||||||||
Cairo |
465.4 |
236.4 |
397.5 |
19/3.98 |
19.9 |
649 |
69.3 |
0.1417 |
||||||||
Darien |
559.5 |
283.6 |
477 |
19/4.36 |
21.8 |
778 |
83.1 |
0.1181 |
||||||||
Elgin |
652.6 |
331 |
556.5 |
19/4.71 |
23.55 |
908 |
97 |
0.1012 |
||||||||
Flint |
740.8 |
374.5 |
636 |
19/3.59 |
25.13 |
1028 |
107.4 |
0.0894 |
||||||||
Greeley |
927.2 |
469.6 |
795 |
19/4.02 |
28.14 |
1289 |
134.6 |
0.0713 |
||||||||
AAAC conductor-ASTM B 399B 399M |
||||||||||||||
Nominal Area |
Stranding |
Overall Diameter |
Weight |
Rated Strength |
Electrical Resistance |
Current Rating* |
||||||||
AWG&MCM |
mm^2 |
No./mm |
mm |
kg/km |
KN |
Ω/Km |
A |
|||||||
6 |
13.2 |
7/1.55 |
4.65 |
36.2 |
4.18 |
2.5361 |
69 |
|||||||
4 |
21.1 |
7/1.96 |
5.88 |
57.9 |
6.69 |
1.586 |
93 |
|||||||
2 |
33.5 |
7/2.47 |
7.41 |
92 |
10.6 |
0.9987 |
123 |
|||||||
0 |
53.5 |
7/3.12 |
9.36 |
146.8 |
17 |
0.62592 |
165 |
|||||||
2/0 |
67.3 |
7/3.50 |
10.5 |
184.8 |
20.4 |
0.49738 |
190 |
|||||||
3/0 |
84.9 |
7/3.93 |
11.79 |
233 |
25.7 |
0.3945 |
219 |
|||||||
4/0 |
107 |
7/4.42 |
13.26 |
294.7 |
32.5 |
0.31188 |
253 |
|||||||
250 |
126 |
19/2.91 |
14.55 |
346.7 |
38.8 |
0.26509 |
280 |
|||||||
300 |
152 |
19/3.19 |
15.95 |
416.7 |
46.6 |
0.22059 |
313 |
|||||||
350 |
178 |
19/3.45 |
17.25 |
487.3 |
52 |
0.1886 |
345 |
|||||||
400 |
203 |
19/3.69 |
18.45 |
557.5 |
59.5 |
0.16486 |
375 |
|||||||
450 |
228 |
19/3.91 |
19.55 |
626 |
66.8 |
0.14683 |
402 |
|||||||
500 |
253 |
19/4.12 |
20.6 |
695 |
74.2 |
0.13224 |
429 |
|||||||
550 |
279 |
37/3.10 |
21.7 |
766.2 |
83.9 |
0.11995 |
455 |
|||||||
600 |
303 |
37/3.23 |
22.61 |
831.9 |
91 |
0.11049 |
478 |
|||||||
650 |
330 |
37/3.37 |
23.59 |
905.5 |
94.9 |
0.1015 |
504 |
|||||||
700 |
354 |
37/3.49 |
24.43 |
971.2 |
101 |
0.09464 |
525 |
|||||||
750 |
381 |
37/3.62 |
25.34 |
1045 |
109 |
0.08796 |
549 |
|||||||
800 |
404 |
37/3.73 |
26.11 |
1109 |
116 |
0.08285 |
569 |
|||||||
900 |
456 |
37/3.96 |
27.72 |
1250 |
131 |
0.07351 |
612 |
|||||||
1000 |
508 |
37/4.18 |
29.26 |
1393 |
146 |
0.06597 |
653 |
|||||||
1250 |
631 |
61/3.63 |
32.67 |
1732 |
179 |
0.05306 |
743 |
|||||||
1500 |
759 |
61/3.98 |
35.82 |
2082 |
215 |
0.04414 |
827 |
|||||||
1750 |
886 |
61/4.30 |
38.7 |
2431 |
251 |
0.03781 |
904 |
|||||||







Send Inquiry to This Supplier
You May Also Like
-
Sick YF8U14-050VA3XLEAX - Sensor/actuator CableNegotiableMOQ: 1 Piece
-
Energy Saving High Temperature Self-Regulating Heat Trace Cable for Industrial ApplicationsUS$ 1.4 - 2.4MOQ: 1 Meter
-
400 Mm2 12 Gauge Insulated Copper WireUS$ 1 - 10000MOQ: 1 Piece
-
Fireproof CableNegotiableMOQ: 500 Meters
-
Pesticide Spraying Machine Wire Harnrss Tractors and Agricultural Machinery Cable AssemblyNegotiableMOQ: 1 Unit
-
Hot Sale Magnet Polyesterimide Flat Enamelled Super Aluminum WireUS$ 4.89MOQ: 500 Kilograms
-
4/8/16/32CH Channels Multi Cable With Wheel/6 UTP Multipair CableUS$ 500 - 800MOQ: 10 Pieces
-
Advanced Self-Regulating Heating Cable for Freeze Protection & Temperature MaintenanceUS$ 0.98MOQ: 10 Meters
-
Sports and Gym Equipment Silicone Grip Pipe Wrapping TapeNegotiableMOQ: 1 Roll
-
Electric Wire CableNegotiableMOQ: 2700 Meters