Home > Electrical & Electronics > Power Supply & Distribution > Power Distribution Cabinet & Box > JD194-BS4Q-Y Three Phase Four Wire Digital ac Reactive Power Transducer

JD194-BS4Q-Y Three Phase Four Wire Digital ac Reactive Power Transducer

JD194-BS4Q-Y Three Phase Four Wire Digital ac Reactive Power Transducer photo-1
Negotiable MOQ: 1 set (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Business Type:
Manufacturer
Year Established:
2010
Annual Export Value:
Above US$100 Million
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.

reactive power transducer

JD194-BS4Q-Y three phase four wire digital ac reactive power transducerJD194-BS4Q-Y three phase four wire digital ac reactive power transducer

                                     

1.Product display

    

                     JD194-BS4Q-Y three phase four wire digital ac reactive power transducer

 

                       

 2.Product introduction

 

BS series measuring transmitters are a kind of device to convert the measured parameters such as current, voltage, power, frequency and power factor to DC current, DC voltage and isolate the output analog signal or digital signals. The transmitters accord with the national standard GB/T 13850 – 1998.

This series digital display AC voltage meters have high environment adaptability because their working temperature range is -40~70 and EMC better than III level. They can be applied in control systems, distribution automation systems, industrial automation systems and intelligent buildings.

 

3.Technical specification

 

Input

Rated value

Current

1A, 5A

 

 

Voltage

100V,220V,380V

 

Overload

Continuous

1.2In,1.2Un

 

 

Instantaneous

10In/5s,2Un/1min

 

Absorption power

(each phase)

Current

0.2VA

 

 

Voltage

0.2VA

 

Frequency

45~65Hz

Output

Rated value

0-5V,0-10V,0-5mA,0-20mA,4-20mA (select one))

 

Load capacity

Current output load≤ 510Ω, Voltage output load≥20k

 

Output ripple

≤ 2 times of basic error

 

Accuracy

0.5

Power supply

Working range

AC/DC 80~270V ,DC19~50V

 

Power consumption

5VA

Response time

400ms

                      

 

3.Similar products

                     JD194-BS4Q-Y three phase four wire digital ac reactive power transducer     

                    JD194-BS4Q-Y three phase four wire digital ac reactive power transducer

 

JD194-BS4Q-Y three phase four wire digital ac reactive power transducerJD194-BS4Q-Y three phase four wire digital ac reactive power transducerJD194-BS4Q-Y three phase four wire digital ac reactive power transducerJD194-BS4Q-Y three phase four wire digital ac reactive power transducer

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2010
Annual Export Value
Above US$100 Million
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe