FA 505 - Dew point sensor for OEM applications
OEM dew point sensors for residual moisture measurement in compressed air and gases
Special features for dew point sensor FA 505:
Optimized design for tight space conditions in drying systems
Measuring range -80...20°Ctd
Extremely long-term stable
Analogue output 4...20 mA or modbus-RTU interface
Condensation insensitive
Quick response time
Pressure-tight up to 350 bar (special version)
NEW: Higher resolution of the sensor signal due to improved evaluation electronics
NEW: Sensor diagnosis on site by means of hand-held instrument or CS Service Software
Measuring range
-80...20°Ctd pressure dew point resp. dew point in °Ctd0...100 %RH
-20...70 c
Other scales on request.
E.g. -60...30°Ctd ^ 4...20 mA
-50...20°Ctd ^ 4...20 mA-40...30°Ctd A 4...20 mA-20...50Ctd 4...20 mA
Accuracy:
typical ± 1°Ctd von 20...-20°Ctd
±2°Ctd von -50...-20°Ctd±3°Ctd von -50...-80 °Ctd
0699.0505-4
FA 505 dew point sensor (-20...50°Ctd) analogue output 4-20mA
o699.0505-5
FA 505 dew point sensor (-40...30°Ctd) analogue output 4-20mA
o699.0505-6
FA 505 dew point sensor (-50...20 °Ctd) analogue output 4-20mA
o699.0505-7
FA 505 dew point sensor (-60...30Ctd) analogue output 4-20mA
o699.0505-8
FA 505 dew point sensor (-80...20 °Ctd) analogue output 4-20mA
0699.0505-10
FA 505 dew point sensor (-20...50°Ctd) Modbus output
o699.0505-11
FA 505 dew point sensor (-40...30 °Ctd) Modbus output
0699.0505-12
FA 505 dew point sensor (-50...20Ctd) Modbus output
0699.0505-13
FA 505 dew point sensor (-60...30°Ctd)Modbus output
0699.0505-14
FA 505 dew point sensor (-80...20°Ctd)Modbus output
0699.3390
Standard measuring chamber for compressed air up to 16 bar
0699.3690
Measuring chamber for atmospheric dew point
cs Service Software for FA/VA sensors incl.PC connection set,
05542007
USB connection and interface adapter to the sensor
0554.0002
Control and calibration set 11.3 % RH
0554.0004
Control and calibration set 33 % RH
0554.0005
Control and calibration set 75.3 % RH
0553.5051
Connection cable for FA 505, length: 5 m
0553.5053
Connection cable for FA 505, length: 10 m
3200.0003
Precision calibration at 0 Ctd and 10 Ctd incl.ISO certificate
0699.3396
Precision calibration at -40 Ctd incl.ISO certificate
Send Inquiry to This Supplier
You May Also Like
-
Kfd2-Crg2-Ex1. D 24 V DC SupplyNegotiableMOQ: 1 Piece
-
Strain Gauge Converter Kfd2-Wac2-Ex1. DNegotiableMOQ: 1 Piece
-
Kfd2-Crg2-Ex1. D 1-Channel Isolated BarrierNegotiableMOQ: 1 Piece
-
Proximity Sensor Q45BW13LV Banner R-GAGE SeriesUS$ 50 - 55MOQ: 1 Piece
-
Radar Sensor Q240RA-CN-AF2Q Dip SwitchUS$ 1500 - 1600MOQ: 1 Piece
-
Mark Sensor R58ECRGB1 Banner Bipolar OutputUS$ 1500 - 1600MOQ: 1 Piece
-
BANNER M12FTH3Q Humidity Sensor With Modbus RTU; RS-485 InterfaceUS$ 100 - 150MOQ: 1 Piece
-
BANNER Momentary Action Touch Button OTBVN6QDUS$ 100 - 130MOQ: 1 Piece
-
Dew Point Measurement DS 52-set for Desiccant DryersNegotiableMOQ: 1 Piece
-
Dew Point Measurement DS 52-set for Refrigeration DryersNegotiableMOQ: 1 Piece