- Acrel Electric Co., Ltd
- China Manufacturer with main products:Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement
Home > Products > Medical intelligent > Operating Room Healthcare Insulation Monitoring Device AIM-M200
Operating Room Healthcare Insulation Monitoring Device AIM-M200
- 1000 Piece / Pieces per Month
- shanghai
- T/T L/C Other
- 7 days
- Industrial Digital Temp Controller With RS485 WHD46-33
- ADL100-ET Din Rail Mounted Energy Current Volt Power Monitor Meter For Ev Charging Pile
- AIL150-4 Insulation Fault Locator For Ungrouded AC/DC Control Systems
- Wireless Harmonic Energy Meter With LORA Communication ADW300
- ASJ10-LD1A Electrical Circuit Protection Current Relay
- Split Open Loop Hall Effect Current Transducer Output 5V/4V Power Supply AHKC-K
Product Details
Brand Name: | Acrel | Place of Origin: | China | Model Number: | AIM-M200 |
Type: | Other, Electrical instrument | Properties: | Medical Materials & Accessories |
Product Description
1. Introduction
AIM-M200 medical intelligent insulation monitoring instrument adopts advanced microcontroller technology, which has high integration, compact size, convenient installation and integrates intelligence, digitalization and networking in one. It is ideal selection for insulation monitoring of isolation power system in medical location of group 2 such as operating room and intensive care unit.
AIM-M200 is usually combined with AITR series medical isolation transformer, AKH-0.66P26 current transformer, AIL100-4/-8 insulation fault locator, ASG100 test signal generator, HDR-60-24 power supply module and AID150/200 centralized alarm display device.
2.Function features of AIM-M200 medical intelligent insulation monitoring instrument
* Functions of real-time monitoring and fault alarming of the ground insulation resistance, transformer load current and transformer winding temperature of the monitored IT system;
* Can be used with insulation fault locator, remotely starting fault-locating and displaying locating results when there are insulation faults;
* Real-time monitor the line disconnection fault, temperature sensor disconnection fault and the functional grounding line disconnection fault of the monitored system, and give the alarm indication when the fault occurs; * Relay alarm output, LED alarm indication and other faults indication functions;
* Two kinds of fieldbus communication technology, which are used for centralized alarm and display instrument, test signal generator, insulation fault locator and upper computer management software communications, and can monitor the operation status of IT system in real time.
* Events logging function, which can record alarm occurrence time and fault type and is convenient for operation personnel to analyze the operation conditions of system and promptly eliminate the faults;
3.Panel description
Medical IT System Insulation Monitoring and Fault Locating Products
1>Introduction
The medical IT system is mainly used in important Class 2 medical locations such as operating room, ICU/CCU intensive care unit, providing safe, reliable and continuous power distribution for the important equipment at these locations. Medical insulation monitoring and fault locating device is developed by the many years’ design experience of the Acrel Electric in electric power meter industry, according to the special requirements of the insulation monitoring and fault locating of the power distribution system in Class 2 medical locations. The products can realize the real-time monitoring of insulation, load and temperature of isolation transformer in IT system, and have the functions of system insulation fault loop positioning and centralized monitoring by multiple pieces of systems. Products conform to the provisions of enterprise standard Q31/0114000129C013-2016 IT System Insulation Monitoring Instrument.
Medical IT system insulation monitoring and fault locating products (seven-piece set) include AITR series medical isolation transformer, AIM-M200 medical intelligent insulation monitoring instrument, AKH-0.66P26 current transformer, AIL100-4/AIL100-8 insulation fault locator, ASG100 test signal generator, DR-60-24 power module and AID200 centralized alarm and display instrument, which are shown in Table 1.
Table 1 Medical IT System Insulation Monitoring and Fault Locating Products
2> Function features
2.1 Function features of AITR series medical isolation transformer
Ø The transformation ratio between the primary and secondary windings is 1:1;
Ø Double insulation treatment is adopted between the windings, and the electrostatic shielding layer is designed.
Ø The PT100 temperature sensor is installed in each wire packet to monitor the temperature of the isolation transformer;
Ø Used for the transformation of TN system into IT system (ungrounded system) after isolation transformer.
2.3 ASG100 test signal generator
Ø The CAN bus technology is used to exchange data with other equipment.
Ø When the monitored IT system has an insulation fault, it can initiate and generate the fault location signal to the system, and realize fault locating function with the help of fault locator;
Ø Functions of L1, L2 disconnection detection, and can display the results through the luminous LED.
2.4 AIL100-4/AIL100-8 insulation fault locator
Ø The CAN bus technology is used to exchange data with other equipment.
Ø Cooperate with ASG100 test signal generator to realize fault locating function, in which the AIL100-4 can locate the insulation faults of 4 circuits and AIL100-8 can locate the insulation faults of 8 circuits. The positioned circuit is indicated by the LED indicator.
2.5 Function features of AID200 centralized alarm and display instrument
Ø Remotely monitor the real-time operation conditions of up to 16 pieces of systems, and the main interface intuitively displays whether the access system communication is intact;
Ø The insulation resistance alarm value, load current alarm value and transformer temperature alarm value of each system insulation monitoring instrument can be set up remotely, and the insulation monitor self-test can be activated remotely.
Ø When there are insulation faults, overload, excessive temperature rise of the voltage transformer or wiring faults in any of the monitored system, centralized alarm and display instrument can provide corresponding sound and light alarm function, and can manually eliminate the alarm sound.
Ø Events logging function, which is convenient for operation personnel to analyze the operation conditions of system and promptly eliminate the faults, and can save maximum of 20 newest records;
2.6 Function features of DR-60-24 power supply instrument
Ø AC 220V input, DC 24V output, with max output power of 60W;
Ø Used for the DC 24V power supply for AIM-M200 medical intelligent insulation monitoring instrument, ASG100 test signal generator, AIL100 series insulation fault locator, AID200 centralized alarm and display instrument and other instruments.
2.7 Function features of AKH-0.66P26 current transformer
*The maximum measurable current is 60A, and the transformation change ratio is 2000:1;
* Work with the AIM-M200 insulation monitoring instrument to measure the load current of isolation transformer.
3> Reference standard
GB 16895.24-2005/IEC 60364-7-710: 2002 Building electrical installations section 7-710: Requirements for special installations or locations medical locations;
IEC 61557-8-2007 Electrical safety of low voltage distribution system below AC 1000V and DC 1500V, Test, measurement or monitoring equipment for protection test section 8: Insulation monitoring device for IT systems;
IEC 61557-9-2007 Electrical safety of low voltage distribution system below AC 1000V and DC 1500V, Test, measurement or monitoring equipment for protection test section 9: insulation fault positioning equipment for IT systems;
JGJ 16-2008 Code for electrical design of civil buildings;
GB19212.1-2008/IEC61558-1: 2005 Safety of power transformers, power supplies, reactors and similar products section 1: General requirements and tests;
GB19212.16-2005/IEC61558-2-15: 1999 Safety of power transformers, power supplies and similar products section 16: Special requirements for isolation transformers for power supply in medical locations.
Acrel Co., Ltd. [Stock Code: 300286.SZ] is one of the few leading companies in China who provides various systematic solutions of power monitoring, power control, energy management and electrical safety for smart grid users.
Certificate
Packing
Shipping
Contact Us:
Contact Us
- Acrel Electric Co., Ltd
- Contact nameShelly Zhang
- Phone86-21-18702111813
- Hospital grade isolation transformers AID150 Alarm And Display Device
- Smart Real-Time Temperature Measuring Device ARTM-8/JC
- Hospital IPS Isolated Power Supply Monitoring System Insulation Monitor
- AKH-0.66 30I KWH Meter Dedicated CT Current Sensor
- AMC72L-AI3 Electricity Meters Radiator Stray Current Meter
- APM830 Three Phase Multi Function Digital Smart Energy Meter
- PZ96-E4 LED Electric Meter AC Smart Power Meter
- Full Power Measurement Modular Design AC Energy Multi-functional Power Meter APM800
- AC Current Transmitter BA50-AI/I AC Current Transducer
- Remote High Voltage Distribution Cabinet Passive Wireless Temperature Sensor ATE400
- ADW200 Din Rail 3 Phase Multi Circuit Power Meter With LoRa Wireless
- Switchgear Bolted Wireless Temperature Sensor ATE100
- Operating Thetre Insulation Monitoring Device For IT system AIM-M100
- Din Rail Eletrical Power Transducer With RS485 BD-4E
- Insulation Fault Location In IT System IEC Certificate AIL100-8
- ACR10R-D16TE Solar Inverter Reverse Power Monitor Meter
- AIM-M10 Medical IT Isolated Power Supply System Insulation Monitor
- Insulation Fault Locator For Ungrouded AC/DC Control Systems AIL150-4
- AID200 Nurse Station Alarm Device For Hospital Isolated Power System
- PZ96-E4 AC Intelligent Three-phase Embedded Power Meter
- Solar Multifunction Power Meter With External Split-core Current Transformer
- AIM-M200 Medical Intelligent Insulation Monitoring Device For Hospital ICU
- ARD2F-25+90L Protection Relay Lcd Display Blocking Motor Protector
- The Isolation Of Medical Systems AIM-M100 Nursing Station Device For Monitoring
Popular Searches
Find Similar Products By Category
- Health & Medical > Medical Devices > Medical Consumables
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shelly Zhang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-