138A Gauss meter and the probe 138A 0.5mm
- 10 Piece / Pieces per Month
- shenzhen
- T/T
Product Details
Brand Name: | sunlight | Place of Origin: | China | Model Number: | 138A |
Weight: | two point eight | Operating Temperature: | 138A | Supply Voltage: | 138A |
Dimensions: | 14(L) x 22.5(H) x 23(D) cm. | Accuracy Class: | 138A | Measuring Range: | 138A |
Product Description
1. Digital Display: 3 1/2 digits, Resolution: 1 gauss.
2. Measuring Range: 0∼20.0K gauss, autoranging. Two ranges: 0∼2.0K, 2.0K∼20.0K gauss.
3. Accuracy (probe excluded): Normal : ±(0.1% Rdg.+ 0.05% FS)
Peak hold : ±(0.2% Rdg.+ 0.1% FS)
(1/4) x 4 : ±(0.3% Rdg.+ 0.1% FS)
4. Peak hold decay <-0.05% /sec.
5. Accuracy ( probe included ) : At 10K gauss : ±1.7%
0 ∼15K gauss : ±(2% Rdg.+ 0.1% FS)
15 ∼20K gauss : ±2.5%
6. Dim. : 14(L) x 22.5(H) x 23(D) cm.
7. Net Weight : 2.8 KGS.
138A Gauss Meter is exclusively used to test the flux density of all kinds of magnetic components. Regardless what its material or the shape of magnet is, Model-138A can test its flux density.
For example: Ferrite Magnets、Flexible Rubber Magnets 、Rare Earth Magnets、Alnico Magnets…can all be tested by Model-138A. Also, Magnets for loudspeaker、headphone、microphone magnet、motor and relay, as well as other magnetism components can all use Model-138A to test its flux denstity.138A is especially designed with “Peak Hold” & “Auto Accumulating and Auto-Averaging” two functions, especially suitable to test the flux density of the magnetic gap of loudspeaker 、headphone and microphone…etc.
2. Peak Hold
To use a Gauss meter without the “Peak Hold” function“ for testing the flux density, due to the unsteady vibration of the Gauss Meter’s needle or the unstable displayed value in course of testing , it is hard to obtain the real “Peak Value”. Model-138A has the “Peak Hold’ function which can test the “Peak Value” easily. If user used a Gauss meter without the “Peak Hold” function to test the flux density in magnetic field, then, he must observe the test value and adjust the testing position simultaneously in course of testing, so to obtain the biggest (ideal) value, in this case, user has to repeat numerous testing, consequently, sensor chip of the probe might got abrasive easily, moreover, it might got broken due to distraction of the user.
3. Auto Accumulating and Auto-Averaging
To test the flux density of the magnetic gap, user must sum up the peak value at the 4 points magnet gap, and divide the total peak values by 4, to get the average peak value. If used a conventional Gauss Meter, user must record down the 4 tested peak values, and compute the average peak value manually, this is inconvenient and time-consuming. 138A is a unique design with “4 times auto accumulating & averaging” functions, rapid test & accurate result.
Contact Us
- Shenzhen BaiChuan Electronics Co., Ltd.
- Contact nameSally Chen Chat Now
- Phone86-755-27709066
- Addresssallychen@szbcelectronics.com Shenzhen,Guangdong
sunlilab | CLIO | SOUNDCHECK | LMS |
DASS | WICKON | 8121C | CRY |
sunlignt | BK | Particle | Audio Analyzer |
- External filter 8121FT-1 IEC268-1
- Noise Generato & aging test 8121C
- Sweeper 7116C 20W/100W/60W Loudspeaker frequency sweeper
- Sweep tester 7116C 20W/100W/60W
- 8121C Noise Generato 8121C Noise Generato
- sunlilab 8121C Noise Generato 8121C Noise Generato
- sunlilab 7116C Sweep tester 7116C 20W/100W/60W
- sunlilab139B Polarity tester and the sensor 139B
- Sunlilab 7117C DIGITAL HIGH SPEED Fo METER 7117C
- sunlilab 138A Gauss meter 138A and 138 probe
- sunlilab 8121FT-1 External filter 8121FT-1 IEC268-1
- sunlilab 152A IMPEDANCE METER 152A SUNLILAB IMPEDANCE METER 152A
Popular Searches
Recommended Products
- sunlilab white noise & pink noise tester 8121C
- 7116C-60W Loudspeaker Acoustic Scanner
- gauss meter and probe sunlilab138A
- 8121FT-1 noise filter IEC60268-1 IEC60065
- 152A IMPEDANCE METER
- 139B loudspeaker polarity tester
- 138A gauss meter and probe
- 7117C Loudspeaker FO tester
- white noise & pink noise tester 8121C
- Acrel Insulation fault locator Accurately locate the circuit where the insulation fault is located AIL150-4
- Acrel Using CAN bus technology, insulation faults of 8 circuits can be located Insulation fault locator AIL150-8
- Acrel current transmitter input AC 0-1/5A output 4-20mA power AC/DC 85-270V BD-AI
Find Similar Products By Category
- Measurement & Analysis Instruments > Electrical Instruments > Other Electrical Instruments
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Sally Chen
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile